Download Panasonic Movicon 11 Programmer Guide

Transcript
Refresh Button Text
This edit box allows you to insert the text to be associated to the Refresh button. When
this field is left empty the default text will be used instead.
Update Button Text
This edit box allows you to insert the text to be associated to the Update button. When
this field is left empty the default text will be used instead.
Save Button Text
This edit box allows you to insert the text to be associated to the Save Button. When this
field is left empty the default text will be used instead.
Select All Button Text
This edit box allows you to insert the text to be associated to the Select All Button. When
this field is left empty the default text will be used instead.
Copy Button Text
This edit box allows you to insert the text to be associated to the Copy Button. When this
field is left empty the default text will be used instead.
Insert Button Text
This edit box allows you to insert the text to be associated to the Insert Button. When this
field is left empty the default text will be used instead.
Delete Button Text
This edit box allows you to insert the text to be associated to the Delete Button. When this
field is left empty the default text will be used instead.
Update Variable
This property allows you to enable the possibility to update the variables which have the
same names as the Table columns with the record values of the selected grid. Updating is
done on the Update button's command.
Grid Execution Properties
The Grid execution properties are used for setting up file connections for display data.
To edit the Execution properties, select the object with the mouse and use the Movicon
"Properties Window".
ODBC DSN
This property allows you to insert or create the ODBC DSN connection to be used for
accessing the Database to be displayed in the Grid.
The ODBC is not supported in WinCE for the time being and therefore the
Database file DSN link cannot be exploited and the Grid's "ODBC DSN"
property has to be changed during its configuration phase. This setting
will then be different according to whether the Grid has to be linked to a
DataLogger/Recipe or to any Database file. In the first case, Movicon will
have already opened connections to the file and therefore the Grid should
be able to exploit them. In the second case, however, the Grid will have
to open a new connection to the DataBase file. As a consequence of this,
the "ODBC DSN" property should be set as follows:
•
•
Connection to DataLogger/Recipe: the DSN name in the
"ODBC DSN" property is replaced with the name of the
DataLogger/Recipe
Connection to DataBase: The DSN name in the "ODBC DSN"
property is replaced with the DataBase file name to be connected
to, without specifying the extension. The DataBase file, in this
case, must be found in the project's DLOGGERS folder or one of
its sub folders
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]