Download Altivar 71

Transcript
Contents
Before you begin_____________________________________________________________________________________________ 4
Documentation structure_______________________________________________________________________________________ 5
Introduction _________________________________________________________________________________________________ 6
Presentation _____________________________________________________________________________________________ 6
Notation ________________________________________________________________________________________________ 6
Bus connection ______________________________________________________________________________________________ 7
Connecting to the Altivar 71 _________________________________________________________________________________ 7
RJ45 connector pinouts ____________________________________________________________________________________ 7
Wiring recommendations ___________________________________________________________________________________ 8
RS485 standard __________________________________________________________________________________________ 8
Modbus standard schematic_________________________________________________________________________________ 9
Connection via RJ45 wiring system __________________________________________________________________________ 10
Connection via junction boxes ______________________________________________________________________________ 12
Connection onto screw terminals ____________________________________________________________________________ 14
Configuration ______________________________________________________________________________________________
Configuring communication parameters _______________________________________________________________________
Control-signal configuration ________________________________________________________________________________
Configuring the communication scanner ______________________________________________________________________
Configuring monitored parameters ___________________________________________________________________________
Configuring communication fault management _________________________________________________________________
15
15
16
19
20
21
Diagnostics ________________________________________________________________________________________________
LEDs __________________________________________________________________________________________________
Communication diagnostics ________________________________________________________________________________
Control-signal diagnostics__________________________________________________________________________________
Communication faults _____________________________________________________________________________________
22
22
23
25
27
Modbus protocol ____________________________________________________________________________________________
RTU mode _____________________________________________________________________________________________
Principle _______________________________________________________________________________________________
Altivar 71 Integrated Modbus _______________________________________________________________________________
Addresses______________________________________________________________________________________________
Modbus functions ________________________________________________________________________________________
Read N output words: Function 3 ____________________________________________________________________________
Write one output word: Function 6 ___________________________________________________________________________
Diagnostics: Function 8 ___________________________________________________________________________________
Write N output words: Function 16 (16#10) ____________________________________________________________________
Identification: Function 43 (16#2B) ___________________________________________________________________________
Read/write N words: Function 23 (16#17) _____________________________________________________________________
Communication scanner ___________________________________________________________________________________
Exception responses _____________________________________________________________________________________
Read non-existent or protected parameters ____________________________________________________________________
28
28
28
29
29
30
30
31
32
33
34
36
37
39
39
Appendix: Non-standard schematics ____________________________________________________________________________
UNI-TELWAY schematic __________________________________________________________________________________
Jbus schematic __________________________________________________________________________________________
Use of UNI-TELWAY slaves in a standard schematic ____________________________________________________________
Recommendations for setting up a Modbus network using non-standard devices_______________________________________
41
41
42
43
44
While every precaution has been taken in the preparation of this document, Schneider
Electric SA assumes no liability for any omissions or errors it may contain, nor for any
damages resulting from the application or use of the information herein.
The products and options described in this document may be changed or modified at
any time, either from a technical point of view or in the way they are operated. Their
description can in no way be considered contractual.
3