Download Facilities Services Construction Standards June 2012

Transcript
Division 14 – Conveying Systems
Page 14 20 00-10
signals, pull sheets, and diagnostic and/or trouble-shooting guide shall be
furnished to Oregon State University.
02. Submit a complete list of all items to be furnished and installed under this
section. Included manufacturer’s specifications, catalog cuts, and other data to
demonstrate compliance with the specified requirements.
03. Submit complete shop drawings for all work in this section, showing dimensions
and locations of all items including supporting structure and clearances
required.
04. Submit two complete clean sets of drawing prints and specifications with “asbuilt” conditions marked in crisp red ink. Sign and attest to the documents as
reflecting all conditions “as-built.”
05. Provide 4 copies of Operation and Maintenance Manuals, Installation Manuals
and Parts Manual necessary for full servicing of the elevator and
microprocessor.
C.
Quality Assurance
01. Elevator installer is responsible for quality assurance and insuring that all
systems related to the function of the elevator are complete and functioning
properly.
D.
Maintenance
01. Starting at the time of substantial completion of the complete project, provide
complete systematic inspection and maintenance of the elevator for a period of
12 months. Furnish trained experts and equipment to check, adjust, lubricate,
and otherwise maintain the elevator in operation without defects or
deterioration. Replace or repair materials and parts which become defective or
deteriorated for any reason except through abuse or misuse by OSU. This time
frame will start with final inspection of the elevator by the state of Oregon.
E.
Use of Elevator
01. The elevator shall not be used temporarily for building construction purposes
unless specifically allowed by the Owner. General contractor responsible for
damages and repairs.
02. If the Contractor is allowed to use the elevator prior to Substantial Completion
of the project, the warranty and service period shall not be compromised and
shall begin when substantial completion is achieved. Final inspection by the
state of Oregon is when OSU takes possession.
F.
Acceptable elevator manufacturers are:
01. Kone Elevator Company
02. Motion Control
03. Otis Elevator Company
04. Thyssen Krupp
05. All companies with non-proprietary equipment
G.
Attributes (Traction Elevator)
01. Traditional machine room set up at top of hoistway
02. Capacity: TBD
Revised June 2012
90