Download "user manual"
Transcript
Spindle Distinctive features Reset during gear stage change z The acceleration is defined in MD: SPIND_OSCILL_ACCEL (acceleration during oscillation). z If the IS “Oscillation speed” (V38032002.5) is reset, the oscillation motion will stop. However, the spindle oscillation mode will not be left. z The spindle override switch is disabled (fixed to 100%). An exception is only the position 0%. z The IS “Reset” (V30000000.7) will not abort oscillation mode. z When indirect measuring systems are used, the synchronization gets lost. No spindle stop is possible due to z IS “Reset” (V30000000.7) z IS “NC Stop” (V32000007.3) if z the spindle is in oscillation mode for gear stage change z the IS “Gear stage changed” (V38032000.3) is not yet present. In these cases, when Reset is selected, the alarm 10640 “Stop during gear stage change not possible”. After the gear stages have been changed, the Reset request is carried out and the alarm deleted if this is still present on the interface. Note Only possibility of abortion: IS “Clear distance to go/spindle reset” (V38030002.2) (own spindle reset) active. 9-12 SINUMERIK 802S/C base line Description of Functions