Download ModelSim SE Reference Manual
Transcript
Commands vlog t— Enable access to tasks and functions. u— Enable access to primitive instances. The tool determines whether you have supplied a module name or a object pathname by the existence of the “PathSeparator” character (set in the modelsim.ini file) in the path. By default, the separator is a ‘/’. An example object pathname specification is: +acc=n+/u1/u2/n2 • -compat Disables optimizations that result in different event ordering than Verilog-XL. Optional. ModelSim Verilog generally duplicates Verilog-XL event ordering, but there are cases where it is inefficient to do so. Using this option does not help you find event order dependencies, but it allows you to ignore them. Keep in mind that this option does not account for all event order discrepancies, and that using this option may degrade performance. Refer to “Event Ordering in Verilog Designs” for additional information. • -compile_uselibs[=<directory_name>] Locates source files specified in a `uselib directive (Refer to “Verilog-XL uselib Compiler Directive”), compiles those files into automatically created libraries, and updates the modelsim.ini file with the logical mappings to the new libraries. Optional. If a directory_name is not specified, ModelSim uses the name specified in the MTI_USELIB_DIR environment variable. If that variable is not set, ModelSim creates the directory mti_uselibs in the current working directory. • -convertallparams Enables converting parameters not defined in ANSI style to VHDL generics of type std_logic_vector, bit_vector, std_logic, vl_logic, vl_logic_vector, and bit. Optional. • +cover <stat> Enables various coverage statistics collection. The use of +cover is recommended over -cover, as it is more powerful and flexible, and often yields better performance. To obtain the behavior of the obsolete -coverAll argument, use the +cover argument without any <stat> characters. Optional. <stat> — one or more of the following characters: b — Collect branch statistics. c — Collect condition statistics. Collects both FEC and UDP statistics, unless -nocoverfec is specified. e — Collect expression statistics, Collects both FEC and UDP statistics, unless -nocoverfec is specified. s — Collect statement statistics. t — Collect toggle statistics. Overridden if ’x’ is specified elsewhere. ModelSim SE Reference Manual, v6.4a 481
Related documents
ModelSim PE Reference Manual
Command - Electrical and Computer Engineering
ModelSim SE Command Reference
ModelSim Reference Manual
ModelSim SE User`s Manual
Volume 6, Issue 2 - Verification Academy
ModelSim 6.4 Quick Guide
Wave Window
Notes - Read
Volume 7, Issue 2 - Verification Academy
ModelSim 6.0 Quick Guide
ModelSim SE User`s Manual