Download M32150 datasheet
Transcript
MULTI-JUNCTION TIMERS 10.3 TOP (16-bit timers related to output) Underflow (second) Underflow (first) Count clock Enable bit Writing to the Adjust register H'(F000+0008+1) H'FFFF H'F000 Counter adjusts H'A000 Counter H'0000 H'F000 Reload register Adjust register (Undefined) H'0008 F/F output Data inverted by underflow Data inverted by underflow TOP interrupt by underflow Note : Detailed timing information in excluded in this illustration. Fig. 10.3.14 Operating example when adjusting in TOP delayed single-shot output mode M32150F4TFP User's Manual 10-67