Download AVT 100

Transcript
im Vertrieb
von
Installation
and Connection,
cont’d
CAMBOARD Electronics
The following diagram shows how to connect your PC or
control system to the RS-232/IR port.
CABLE
RESERVED
12V
0.5A MAX
150' (45 m) maximum
IR +12
AUDIO
L
R
TV
Video
0
4
IR +12V
AVT 100 Tuner
Rear Panel
RS-232/IR Port
Tx Rx
8
Tx Rx
RF
POWER
VID
ANT
RS-232/IR
RS-232 / IR
OUTPUT
ANT IN
1
5
9
MUTE
2
6
ENTER
TUNE
PRESET
Channel
3
7
Audio
SAVE
AVT 100 REMOTE
SIGNAL
AVT 100 Rear Panel
AVT 100 Remote
IR LINK
Connect a ground wire
between the AVT 100 and the
computer or control system.
Using the AVT 100 IR Remote with the IR Link
The following diagram shows how to wire the AVT 100 to use
the infrared remote control with the optional IR Link.
Transmit (Tx)
Receive (Rx)
0
9
5
1
TV
4
6
2
SAVE
7
3
Audio
ENTER
TUNE
OUTPUT
ANT IN
POWER
RF
12V
0.5A MAX
VID
RS-232 / IR
Tx Rx
L
IR +12
R
ANT
Connecting the AVT 100 to the IR Link
The optional IR Link Infrared Signal Repeater can be connected
directly to an AVT 100. To wire the IR Link for use with your
AVT 100, follow these steps:
AVT 100 Rear Panel
12
Prepare the site and install a wall box, following the
directions in the IR Link User’s Manual, provided with your
IR Link equipment.
2-6
IR
+12 VDC A
Modulated IR D
Ground ( ) B
IR Link Rear Panel
Wiring the IR Link to the AVT 100
2.
Cut a length of 150' (45 m) or less of Extron Comm-Link
cable to go between the AVT 100 and the IR Link.
3.
Attach a 3.5 mm, 5-pole captive screw connector to each
end of the cable. Only three wires (between pins A, B, and
D on the IR Link end, and pins Ground, IR, and +12 on the
AVT 100 end) are required. Wire the cable as shown in the
illustration on the next page. Connectors are included
with the IR Link, but the cable must be purchased
separately.
4.
Plug the 5-pole connector into one of the IR Link’s
communications connectors.
5.
Plug the other end of the cable into the RS-232/IR port on
the rear panel of the AVT 100.
C
MUTE
PRESET
Channel
AVT 100 Remote
Wiring the AVT 100 to a PC or control station
through the RS-232/IR port
1.
Video
8
Computer or
Control System
RS-232 Port
AVT 100 REMOTE
If you use cable that has a
drain wire, tie the drain wire
to ground at both ends.
CABLE
RESERVED
Ground ( ) Green
Receive (Rx) Orange
Transmit (Tx) Red
IR Link
N
The ground pin is shared between RS-232 control and
the IR Link connection.
Do not connect more than one IR Link (either in
parallel or in series) to a tuner.
www.camboard.de
AVT
100 • Installation and Connection
Tel. 07131 911201
Fax 07131 911203
[email protected]
AVT 100
• Installation and Connection
2-7