Download Team Name: iSEDE
Transcript
Student Experiment Documentation Page 134 Figure 5-2: Deployment in Vacuum Chamber Inflation tests have been repeated in vertical configuration and successfully completed. Table 5-28: Test Results #0.3 Test number 0.3 / completed (15.08.2013) Test type Functionality micro pumps Results Controller was able to actuate Bartels micro pumps in and outside the vacuum chamber. When connected to the soft robotic actuator, micro pump was able to inflate actuator. Table 5-29: Test Results #0.4 Test number 0.4 / completed (20.08.2013) Test type Shape changing of structure Results 04-1 Deformation of structure without soft robotic actuator, micropums and added electronics was proven with manual actuation. Single cells in the 5x2 satellite were deflated and a deformation was observed. 04-2 When connected to the soft robotic actuator, micro pump was able to inflate actuator. Table 5-30: Test Results #0.5 Test number 0.5 / Completed Test type Feedback position control Results Readings of IMUs and cameras were taken in lab assembly but need to verified during launch campaign. Table 5-31: Test Results #0.6 BX16_iSEDE_SEDv5-1-31JAN14