Download with MECHATROLINK-III Interface
Transcript
4-2 4.1.2 Output Relays Figure 4.2 shows a list of output relays that are provided with the module. In the table, "" denotes the FA-M3 slot number where the module is mounted. Table 4.2 List of Output Relays Output Relay No. Y33 Y34 Y35 Y36 Y37 Y38 Y39 Y40 Y41 Y42 Y43 Y44 Y45 Y46 Y47 Signal Name AX1 Send Command AX2 Send Command AX3 Send Command AX4 Send Command AX5 Send Command AX6 Send Command AX7 Send Command AX8 Send Command AX9 Send Command AX10 Send Command AX11 Send Command AX12 Send Command AX13 Send Command AX14 Send Command AX15 Send Command Start/Stop Y48 Communication Output Relay No. Y49 Y50 Y51 Y52 Y53 Y54 Y55 Y56 Y57 Y58 Y59 Y60 Y61 Y62 Y63 Y64 Description Request to send MECHATROLINK-III command for axis 1. Request to send MECHATROLINK-III command for axis 2 Request to send MECHATROLINK-III command for axis 3 Request to send MECHATROLINK-III command for axis 4 Request to send MECHATROLINK-III command for axis 5 Request to send MECHATROLINK-III command for axis 6 Request to send MECHATROLINK-III command for axis 7 Request to send MECHATROLINK-III command for axis 8 Request to send MECHATROLINK-III command for axis 9 Request to send MECHATROLINK-III command for axis 10 Request to send MECHATROLINK-III command for axis 11 Request to send MECHATROLINK-III command for axis 12 Request to send MECHATROLINK-III command for axis 13 Request to send MECHATROLINK-III command for axis 14 Request to send MECHATROLINK-III command for axis 15 Request to start or stop MECHATROLINK-III communication Signal Name Description Relation with Other Relays Turn off this relay after verifying that X01 has turned on. Turn off this relay after verifying that X02 has turned on. Turn off this relay after verifying that X03 has turned on. Turn off this relay after verifying that X04 has turned on. Turn off this relay after verifying that X05 has turned on. Turn off this relay after verifying that X06 has turned on. Turn off this relay after verifying that X07 has turned on. Turn off this relay after verifying that X08 has turned on. Turn off this relay after verifying that X09 has turned on. Turn off this relay after verifying that X10 has turned on. Turn off this relay after verifying that X11 has turned on. Turn off this relay after verifying that X12 has turned on. Turn off this relay after verifying that X13 has turned on. Turn off this relay after verifying that X14 has turned on. Turn off this relay after verifying that X15 has turned on. X16 shows the current communication status. Relation with Other Relays (system reserved) (system reserved) (system reserved) (system reserved) (system reserved) (system reserved) (system reserved) (system reserved) (system reserved) (system reserved) (system reserved) (system reserved) (system reserved) (system reserved) (system reserved) Clear Error/warning Request to clear all errors and warnings Turn off this relay after verifying that X32 has turned off. CAUTION In a multi-CPU system, only one CPU module can be configured to use the positioning module. For details on CPU configuration, see "FA-M3 Programming Tool WideField2 User's Manual" (IM34M06Q15-01E). IM 34M06H60-03E 1st Edition : Jan. 2010-00