Download CD326 (EpCAM) MicroBeads
Transcript
Order no. 130-061-101 Magnetic separation with XS Columns For instructions on the column assembly and the separation, refer to the XS Column data sheet. Depletion with LD Columns 1. Place LD Column in the magnetic field of a suitable MACS Separator. For details see LD Column data sheet. 2. Prepare column by rinsing with 2 mL of buffer. 3. Example of a separation using CD326 (EpCAM) MicroBeads Enrichment of tumor cells from PBMCs spiked with cells from a breast cancer cell line (BT474) using CD326 (EpCAM) MicroBeads, a MiniMACS™ Separator, and an MS Column. Cells are fluorescently stained with CD326 (EpCAM)-FITC (# 130-080-301) and CD45-PE (# 130-080-201). Cell debris and dead cells are excluded from the analysis based on scatter signals and PI fluorescence. 3. Apply cell suspension onto the column. Collect unlabeled cells that pass through and wash column with 2×1 mL of buffer. Collect total effluent. This is the unlabeled cell fraction. CD45-PE 4. Cell mixture before separation Depletion with CS Columns 1. Assemble CS Column and place it in the magnetic field of a suitable MACS Separator. For details see CS Column data sheet. 2. Prepare column by filling and rinsing with 60 mL of buffer. Attach a 22G flow resistor to the 3-way-stopcock of the assembled column. For details see CS Column data sheet. CD326 (EpCAM)-FITC 3. Apply cell suspension onto the column. Negative fraction with cells depleted of breast cancer cells For instructions on column assembly and separation refer to the D Column data sheet. Positive fraction with enriched breast cancer cells CD45-PE Depletion with D Columns CD45-PE 4. Collect unlabeled cells that pass through and wash column with 30 mL buffer from the top. Collect total effluent. This is the unlabeled cell fraction. Magnetic separation with the autoMACS™ Separator ▲ Refer to the autoMACS™ User Manual for instructions on how to use the autoMACS Separator. 1. 2. Place tube containing the magnetically labeled cells in the autoMACS Separator. For a standard separation, choose one of the following separation programs: Positive selection: "Posseld" Depletion: "Depletes" ▲ Note: Program choice depends on the isolation strategy, the strength of magnetic labeling and the frequency of magnetically labeled cells. For details see autoMACS user manual, section autoMACS Cell Separation Programs. 3. When using the program "Posseld", collect positive fraction from outlet port pos2. This is the purified CD326 (EpCAM)+ cell fraction. CD326 (EpCAM)-FITC Prepare and prime autoMACS Separator. When using the program "Depletes", collect unlabeled fraction from outlet port neg1. This is the CD326 (EpCAM)- cell fraction. CD326 (EpCAM)-FITC 4.References 1. Moldenhauer, G. et al. (1987) Epithelium-specific surface glycoprotein of Mr 34,000 is a widely distributed human carcinoma marker. Br. J. Cancer 56: 714– 721. 2. Coligan, J. E. et al. (eds.): Current Protocols in Immunology. New York, John Wiley & Sons, Inc. (1994). 3. Garau, D. et al. (1997) Detection of Breast Cancer Cells using the Magnetic Cell Separation (MACS) System: Implications for Stem cell Purging. Europ. J. Histochem. 41(S2): 18–19. [378] 4. Krüger, W. et al. (1999) Improvement of breast cancer cell detection by immunomagnetic enrichment. Cytotherapy 1: 135–139. [568] 5. Krüger, W. et al. (2000) Immunomagnetic tumor cell selection-implications for the detection of disseminated cancer cells. Transfusion 40: 1489–1493. [984] 6. Leinung, S. et al. (2000) Cytokeratin-positive cells in bone marrow in comparison with other prognostic factors in colon carcinoma. Langenbeck's Arch. Surg. 385: 337–343. [986] 7. Tögel, F. et al. (2001) Urokinase-like Plasminogen Activator Receptor Expression on Disseminated Breast Cancer Cells. J. Hematother. Stem Cell Res. 10: 141–145. [985] 140-000-108.09 www.miltenyibiotec.com Unless otherwise specifically indicated, Miltenyi Biotec products and services are for research use only and not for diagnostic or therapeutic use. page 3/4