Push the TUNE ROTARY SWITCH: at this point the parameter is selected, its frame is
shown in red and its name in blue (only one value common to all channels; pre-set value
is picked from Channel 0); it is now possible to change the parameters value.
Fig. 3.21: Group VSET access screen
Turn the TUNE ROTARY SWITCH until the value digit to be edited is shown in blue, the
parameter name in yellow
Fig. 3.22: Group VSET digit selection screen
Push the TUNE ROTARY SWITCH: at this point the value digit becomes yellow and can
be edited
Fig. 3.23: Group Channel VSET digit access screen
Turn the TUNE ROTARY SWITCH until the digit reaches the desired value
Fig. 3.24: Group VSET digit adjust screen