F579 F586 Pattern #10 Characteristics (Pattern Run) Direct Access Number — F579 Program ⇒ Pattern Run Control Parameters ⇒ Preset Speeds ⇒ 10 Parameter Type — Selection List Factory Default — Time From Start Same as #1 Pattern Characteristics (see F570). Changeable During Run — No Pattern #11 Characteristics (Pattern Run) Direct Access Number — F580 Program ⇒ Pattern Run Control Parameters ⇒ Preset Speeds ⇒ 11 Parameter Type — Selection List Factory Default — Time From Start Same as #1 Pattern Characteristics (see F570). Changeable During Run — No Pattern #12 Characteristics (Pattern Run) Direct Access Number — F581 Program ⇒ Pattern Run Control Parameters ⇒ Preset Speeds ⇒ 12 Parameter Type — Selection List Factory Default — Time From Start Same as #1 Pattern Characteristics (see F570). Changeable During Run — No Pattern #13 Characteristics (Pattern Run) Direct Access Number — F582 Program ⇒ Pattern Run Control Parameters ⇒ Preset Speeds ⇒ 13 Parameter Type — Selection List Factory Default — Time From Start Same as #1 Pattern Characteristics (see F570). Changeable During Run — No Pattern #14 Characteristics (Pattern Run) Direct Access Number — F583 Program ⇒ Pattern Run Control Parameters ⇒ Preset Speeds ⇒ 14 Parameter Type — Selection List Factory Default — Time From Start Same as #1 Pattern Characteristics (see F570). Changeable During Run — No Pattern #15 Characteristics (Pattern Run) Direct Access Number — F584 Program ⇒ Pattern Run Control Parameters ⇒ Preset Speeds ⇒ 15 Parameter Type — Selection List Factory Default — Time From Start Same as #1 Pattern Characteristics (see F570). Changeable During Run — No Pattern Run #1 Run-Time Setting Direct Access Number — F585 Program ⇒ Pattern Run Control Parameters ⇒ Preset Speeds ⇒ 1 Parameter Type — Numerical Factory Default — 5 This parameter sets the run-time value for the #1 Preset Speed mode when used as part of a Pattern Run. Changeable During Run — No Minimum — 1 Maximum — 8000 Units — Seconds Pattern Run #2 Continuation Mode Run-Time Setting Direct Access Number — F586 Program ⇒ Pattern Run Control Parameters ⇒ Preset Speeds ⇒ 2 Parameter Type — Numerical Factory Default — 5 This parameter sets the run-time value for the #2 Preset Speed mode when used as part of a Pattern Run. Changeable During Run — No Minimum — 1 Maximum — 8000 Units — Seconds HX7 ASD Programming and Operation Manual 139 Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]