Download MC56F8006 / MC56F8002 - Reference Manual
Transcript
System Integration Module (SIM) 14.3 14.3.1 Functional Descriptions Clock Generation Overview The SIM uses master clocks from the OCCS module to produce the peripheral and system (DSC core and memory) clocks. A 3x master clock input from OCCS operates at three times the system and peripheral bus rate and therefore a maximum of 96 MHz. A 2x(_b) clock input from OCCS operates two times the system and peripheral bus rate and therefore a maximum of 64 MHz. Peripheral and system clocks are generated at a maximum of 32 MHz by dividing the 2x master clock by 2 and gating it with appropriate power mode and clock gating controls. The PWM, TMR, and SCI peripheral clocks can optionally be generated at three times the normal rate at a maximum 96 MHz. These clocks are generated by gating the 3x master clock with appropriate power mode and clock gating controls. The OCCS configuration controls the operating frequency of the SIM master clocks. In the OCCS, either an external clock (CLKIN), a crystal oscillator, or the relaxation oscillator can be selected as the master clock source (master clock). An external clock can be operated at any frequency up to 64 MHz. The crystal oscillator can only be operated at 8 MHz. The relaxation oscillator can be operated at full speed (8 MHz), standby speed (400 kHz using ROSB), or powered down (using ROPD). An 8 MHz master clock can be multiplied to 192 MHz using the PLL and post-scaled to provide a variety of high speed clock rates. Either the post-scaled PLL output or master clock signal can be selected to produce the master clocks to the SIM. When the PLL is selected, the 3x clock is the post-scaled PLL/2 and the 2x clock is the post-scaled PLL/3. When the PLL is not selected, the 3x clock is disabled and the 2x clock is master clock. In combination with the OCCS module, the SIM provides power modes (see next section), clock enables (PCEn registers, SDn registers, CLK_DIS, ONCE_EBL), and clock rate controls (TMR_CR, PWM_CR, SCI_CR) to provide flexible control of clocking and power use. The SIM’s PCEn peripheral clock enable controls can be used to disable individual peripheral clocks when not needed. The clock rate controls enable the high speed clocking option for the general purpose timers (TMR), the PWM, and the serial communications interface (SCI), but require the PLL to be on and selected. See the OCCS manual and other peripheral manuals for further details. 14.3.2 Power-Down Modes Overview The 56800E DSC core operates in one of the power-down modes shown in Table 14-17. Table 14-17. Clock Operation In Power-Down Modes Mode System Clocks Peripheral Clocks Description Run Core and memory clocks enabled. Peripheral clocks enabled Device is fully functional. Freescale Semiconductor 14-25