Download MC56F8006 / MC56F8002 - Reference Manual

Transcript
System Integration Module (SIM)
14.3
14.3.1
Functional Descriptions
Clock Generation Overview
The SIM uses master clocks from the OCCS module to produce the peripheral and system (DSC core and
memory) clocks. A 3x master clock input from OCCS operates at three times the system and peripheral
bus rate and therefore a maximum of 96 MHz. A 2x(_b) clock input from OCCS operates two times the
system and peripheral bus rate and therefore a maximum of 64 MHz. Peripheral and system clocks are
generated at a maximum of 32 MHz by dividing the 2x master clock by 2 and gating it with appropriate
power mode and clock gating controls. The PWM, TMR, and SCI peripheral clocks can optionally be
generated at three times the normal rate at a maximum 96 MHz. These clocks are generated by gating the
3x master clock with appropriate power mode and clock gating controls.
The OCCS configuration controls the operating frequency of the SIM master clocks. In the OCCS, either
an external clock (CLKIN), a crystal oscillator, or the relaxation oscillator can be selected as the master
clock source (master clock). An external clock can be operated at any frequency up to 64 MHz. The crystal
oscillator can only be operated at 8 MHz. The relaxation oscillator can be operated at full speed (8 MHz),
standby speed (400 kHz using ROSB), or powered down (using ROPD). An 8 MHz master clock can be
multiplied to 192 MHz using the PLL and post-scaled to provide a variety of high speed clock rates. Either
the post-scaled PLL output or master clock signal can be selected to produce the master clocks to the SIM.
When the PLL is selected, the 3x clock is the post-scaled PLL/2 and the 2x clock is the post-scaled PLL/3.
When the PLL is not selected, the 3x clock is disabled and the 2x clock is master clock.
In combination with the OCCS module, the SIM provides power modes (see next section), clock enables
(PCEn registers, SDn registers, CLK_DIS, ONCE_EBL), and clock rate controls (TMR_CR, PWM_CR,
SCI_CR) to provide flexible control of clocking and power use. The SIM’s PCEn peripheral clock enable
controls can be used to disable individual peripheral clocks when not needed. The clock rate controls
enable the high speed clocking option for the general purpose timers (TMR), the PWM, and the serial
communications interface (SCI), but require the PLL to be on and selected. See the OCCS manual and
other peripheral manuals for further details.
14.3.2
Power-Down Modes Overview
The 56800E DSC core operates in one of the power-down modes shown in Table 14-17.
Table 14-17. Clock Operation In Power-Down Modes
Mode
System Clocks
Peripheral Clocks
Description
Run
Core and memory
clocks enabled.
Peripheral clocks
enabled
Device is fully functional.
Freescale Semiconductor
14-25