Download OPM-4260 MFC User Manual

Transcript
New Multi Function Controller
ON
OFF
ID SETTING
1
2
3
4
5
6
7
8
9
OFF
DVI 1
DVI 2
0
SET
BROADCAST
ON
A
B
ORION CO., LTD.
INFO
www.oriondisplay.net
DVI
DVI CONVERTER INPUT
VIDEO
Address: 257-6, Gongdan-dong, Gumi-si, Gyeongsangbuk-do, Korea
Tel : +82-2-6678-8533, Fax: +82-2-6678-8599
PC
DTV
S-VIDEO
HDSDI
DVIC1
DVIC2
OUTPUT
HDMI
INFO
AUTO
FUNCTION
MPDP
PDP
REMOTE CONTROL
• 2011.09.30
User's Manual
Thank you for purchasing our New Multi Function Controller.
Please read through this user's manual for safety before installing this product.
This product is manufactured for Multi Plasma display model only.
New Multi Function Controller
Infinitely Expandable
Product & Accessary
Contents
Please check remote controller and all the accessories are included in the
box
ON
ID SETTING
1
2
3
5
6
7
8
9
SET
BROADCAST
ON
02. Product Introduction................................................................4
OFF
Introduction.......................................................................................4
DVI 1
DVI 2
0
Features.............................................................................................4
A
B
Advantages .....................................................................................4
INFO
DVI
03. User Guide Information..........................................................5
DVI CONVERTER INPUT
VIDEO
Cautions for New MFC..................................................................2
Cautions for Adapter......................................................................3
OFF
4
01. Safety Precautions...................................................................2
PC
DTV
S-VIDEO
HDSDI
DVIC1
DVIC2
OUTPUT
HDMI
Remote Controller............................................................................5
INFO
AUTO
FUNCTION
New MFC..........................................................................................6
MPDP
04. New MFC Installation..............................................................8
PDP
REMOTE CONTROL
05. How to use Remote Controller........................................ 10
Remote Controller : 1EA
Multi Function Controller : 1EA
05-1. Power ON/OFF .............................................................. 10
05-2. BROADCAST ................................................................... 10
05-3. AUTO Tracking (PC Mode Only)................................. 11
05-4. DVI Selector...................................................................... 11
05-5. Mode change................................................................... 12
05-6. Input Selection ................................................................ 20
05-7. X x Y Configuration
(e.g. Horizontal 5 sets x Vertical 6 sets)............23
Manual : 1EA
RS-232C Cable : 1EA
Battery (AAA) : 2EA
05-8. BIC control Setting
(Only applicable to OPM-4250, OPM-4250R)....... 25
05-9. Baud-Rate Configuration.............................................. 26
06. Before calling for service................................................... 27
07. Specification............................................................................ 28
L-Bracket : 2EA
Adapter 1EA
box 1EA
ORION CO., LTD. | 1
New Multi Function Controller
Infinitely Expandable
01. Safety Precautions
Cautions for New MFC
ƒƒ Please do not use at the places
of hot and humid environment.
- It may damage the product.
ƒƒ Do not touch the power cable
with wet hands.
- It may cause an electric shock.
Cautions for Adapter
ƒƒ Do not store or use flammables
like a combustible spray around
the product.
- It has a possible danger of explosion
or fire.
ƒƒ Do not put the product under
the direct sunlight or near to hot
places.
- It may cause fire.
ƒƒ Do not spray water directly on
the product.
- It may cause an electric shock or fire.
ƒƒ Please be careful not to soak
unknown material or liquid into
the product.
- It may damage the product.
ƒƒ Do not disassemble, repair or alter the
product with users' own intention.
- It may cause an electric shock or fire. If you
need to test, adjust or repair the product,
contact with an authorized service center.
ƒƒ If you detect smoke, smell or strange sound
from the product, stop using the product
immediately, disconnect the power cable and
contact with an authorized service center.
ƒƒ Use the provided adapter
- Improper adapters may damage
the product. If you cannot use the
provided adapter, use the adapter of
proper specification.
- It may cause an electric shock.
ƒƒ Do not put a heavy object on the ƒƒ Do not connect to a multicable or fold the cable.
power-socket together with
many other electric products.
- It may cause an electric shock or fire.
ƒƒ Make sure the power plug is
properly connected.
- Loose connection may cause an
electric shock.
ƒƒ Disconnect the power plug on
the occasion of lightning.
- It may damage the product.
- It may cause an electric shock or fire.
- It may cause an electric shock or fire.
ƒƒ Carefully move the product not to ƒƒ Please do not stack heavy
give any shock.
objects on top of the product.
- It may cause product malfunction.
- It may damage
the product.
ƒƒ Please keep away from
children's reach.
Notice to users
- If they drop Remote Controller, it may
hurt the children or cause product
malfunction.
Class A digital device
Warning
2 | ORION CO., LTD.
ƒƒ Do not touch the adapter with
wet hands.
It is a device designed for business purpose with a safety
certificate for electromagnetic interference, which user should
be mindful of.
ORION CO., LTD. | 3
New Multi Function Controller
Infinitely Expandable
02. Product Introduction
03. User Guide Information
Introduction
Remote Controller
New MFC (Multi Function Controller) is designed for functional expansion and compensation
in communication and users’ convenience. It provides various communicational interfaces
OFF
Turn on/off MPDP.
ID Setting
1
2
3
Set the number of MPDP in horizontal and vertical positions. (XxY)
4
5
6
7
8
9
X x Y Setting
Features
MPDP is mainly controlled through the Serial communication (RS-232C). However,
gradually, USB and Ethernet port are replacing Serial port in control devices such as
computers. New MFC can support either case. Based on installation circumstance or
Users’ preference, Serial (RS-232), USB or Ethernet can be selected. Especially, Ethernet
allows controlling MPDP through LAN network or even with Internet. Users can have
better communication quality with 4-channel serial port equipped in a New MFC. It helps
avoiding possible undesirable communicational distortion from multiple daisy-chains.
ON
POWER ON/OFF
Enter X x Y setting mode.
ID SETTING
of Serial, USB and Ethernet and also provides 4-channel daisy chain port to solve the
most critical problem of serial communication. Users can find out the status of the product
with the LED indicators. It is also functioning as a BIC controller and a receiver for Remotecontroller.
OFF
DVI 1
DVI 2
0
SET
BROADCAST
ON
B
DVI
DVI Converter Output
Advantages
Function A / B
DVI CONVERTER INPUT
VIDEO
Select DVI Converter output,
DVIC1 or DVIC2.
MPDP Input select
Enter to the test mode of New MFC
INFO
Select directions to set the number
of MPDP (horizontal or vertical) and
check the status of MPDP.
Broadcast is the function to control all
MPDP sets at once. It is applied for
Power On/Off and Auto tracking.
Select DVI input of MPDP,
DVI 1 or DVI 2.
A
Direct & Info key
Broadcast
PC
DTV
S-VIDEO
HDSDI
DVIC1
DVIC2
OUTPUT
HDMI
INFO
AUTO
FUNCTION
MPDP
DVI Converter Input Select
Select source input for DVI converter.
DVI Converter INFO / AUTO
Check the current status information
of DVI converter and execute Auto
tracking.
PDP
REMOTE CONTROL
1. Expand the communicational functions of MPDP. (Serial / USB / Ethernet / IR)
2. Prevent possible communicational distortion from using Serial port by 4-channel
serial port.
3. It transmits the information for BIC by communicating with MPDP without additional
applications. (Only applicable to OPM-4250, OPM-4250R)
4. Control the main functions of MPDP and DVI converter by a remote controller without
additional applications.
4 | ORION CO., LTD.
1.Note :
2.How to mount batteries
 Use two 1.5V AAA-type batteries.
 Do not mix old and new batteries,
 Do not mix different types or makes of
batteries. Mixed use of Alkaline, Manganese
or Re-chargeable batteries are NOT
recommended.
 Only use two batteries of
the same type and make.
 Slide the cap at the rear side of the remote controller to open.
 Insert batteries with the correct polarity and close the cap.
ORION CO., LTD. | 5
New Multi Function Controller
Infinitely Expandable
New MFC
D
1.Front side
E
G
2.Rear side
A
A
B
C
F
B
C
D
E
F
H
A.Power On Indicator
It is turned on when "Power-On" command is received from the remote-controller.
B.Power Off Indicator
It is turned on when "Power-Off" command is received from the remote-controller.
C.MPDP configuration Indicator
It indicates the configuration of "X x Y" in the 7-segments.
D.IrDA Receiver
It is the reception position for the IR signal from the remote-Controller.
E. Indicator for DVI Input selection of MPDP
It is turned on for "DVI1 channel" and turned off for "DVI2 channel".
F. Input Mode Indicator
It indicates the current input source.
G.DVI Converter DVI Output Indicator
A.Power connector
Power connection for 5~9V
B.Service Port
It is a port for program download and debugging.
C.USB Port (Type B)
It is used for communication when the interface is changed to USB mode.
D.Ethernet Port
If it is directly connected to an external control device, "Crossover Network Cable" must be used.
If it is connected to a hub, "Straight-Through Network Cable" must be used.
E. 1 Channel Serial Port (R/A 9pin DSUB-female)
It is a connection port between Main board and sub board.
F. 4-Channel daisy-chain Serial Port (R/A 9pin DSUB-male)
It is used to connect with MPDP. Each channel can used to connect 25 MPDP daisy-chain.
It indicates the current DVI output.
H.Converting switch and indicator for communication Interface
They are push button switches and indicators for communication interface (Serial/IR/USB/Ethernet).
6 | ORION CO., LTD.
ORION CO., LTD. | 7
New Multi Function Controller
Infinitely Expandable
04. New MFC Installation
DVI-D_1
OUTPUT
1. C
onnect RS-232C cable and a power adapter and install at the location of good remote
control reception. Use L-brackets to install at the side of the set.
2.Connect a computer and the New MFC with at least one of Ethernet, RS-232C, and USB
port and connect the MPDP to the RS-232C output in the New MFC. Users can control
MPDP with one of Ethernet, RS-232, USB, and IR remote controller.
3. S
et the number of MPDP units as instructed in <Configuration Mode> in the manual.
(Initial setting is 3X3)
4. T
he LED lamps in the New MFC indicate the previous or initial input source at first,
please select input source once again after power supply.
(Default; previous input source).
※Caution : P
lease do not directly expose the IrDA Receiver to fluorescent lamps. It may
cause malfunction.
DVI-D_1
RS-232C
INPUT
ID 1
RS-232C
INPUT
OUTPUT
OUTPUT
INPUT
ID 4
ID 7
DVI-D_1
RS-232C
INPUT
OUTPUT
OUTPUT
OUTPUT
INPUT
DVI-D_1
RS-232C
INPUT
INPUT
ID 6
INPUT
DVI-D_1
INPUT
OUTPUT
OUTPUT
ID 5
RS-232C
OUTPUT
DVI-D_1
RS-232C
INPUT
OUTPUT
OUTPUT
OUTPUT
INPUT
DVI-D_1
RS-232C
INPUT
INPUT
ID 3
INPUT
DVI-D_1
INPUT
OUTPUT
OUTPUT
ID 2
RS-232C
OUTPUT
DVI-D_1
RS-232C
OUTPUT
OUTPUT
ID 8
ID 9
INPUT
L-Bracket
PWR ON
INPUT
OUTPUT
INPUT
PWR OFF
RS-232C
HOR
VER
IR
DVI
PC
DVI 1/2
DTV
RS-232C
DVI Signal Distributor
(UXGA : UP TO 165MHz)
VIDEO
S-VIDEO
USB
Ethernet
HDSDI
DVIC1
HDMI
DVIC2
IR
ETHERNET
RS232
USB
MSCS control PC
New MFC
New MFC
Video Source
ON
OFF
1
ID
SE
4
ING
TT
7
2
5
SE
8
0
T
9
INFO
I CO
NV
ER
PC
TE
I
O
S-VI
DT
DE
O
DV
IC1
OU
TP DVIC
2
UT
MP
DP
RE
AS
T
F
I1
I2
B
DV
DV
VIDE
OA
DC
ON
OF
DV
DV
A
BR
3
6
INFO
FU
NC
R IN
V
HD
SD
I
PU
T
HD
MI
AU
TION TO
MO
P
TE DP
CO
NT
RO
L
8 | ORION CO., LTD.
Remote Controller
ORION CO., LTD. | 9
ON
New Multi Function Controller
ID SETTING
05. How to use Remote Controller
OFF
1
2
3
4
5
6
7
8
9
OFF
DVI 1
DVI 2
0
SET
A
05-1. Power ON/OFF
Every command is executed on all MPDP sets.
ON
3
4
5
6
PWR ON
8
9
ID SETTING
2
7
INFO
It is available only with PC mode. When it is connected with DVI converter, Auto
Tracking is used to correct the distorted screen alignment.
DVI 1
PWR OFF
DVI 2
2) MPDP is turned on as the PWR LED of the New MFC is turned
on.
3
DTV
ID SETTING
DVI 1
PWR OFF
8
1
2
3
4
5
6
7
8
9
HDMI
OFF
HDSDI
6
9
INFO
AUTO
DVI
2
FUNCTION
2) MPDP is turned off as the PWR LED of the New MFC is turned
off.
A
SET
05-2. BROADCAST
BROADCAST is a command to make all MPDP perform Power On, Off or Auto
Tracking simultaneously.
DVI CONVERTER INPUT
VIDEO
S-VIDEO
ON
HDMI
HDSDI
OFF
BROADCAST
ON
INFO
AUTO
3FUNCTION
DVIC1
DVIC2
1OUTPUT2
ID SETTING
MPDP
4
5
7
8
6
DVI 1
B
INFO
PDP
INFO
REMOTE CONTROL
DTV
OFF
A
B
PC
BROADCAST
ON
DVI
1) Press DVI 1 or DVI 2 buttons in the Remote controller.
DVI 2
0
MPDP
SET
DVI
OFF
It is used to select DVI 1 input or DVI 2 input.
ID SETTING
OFF
DVIC1
DVIC2
OUTPUT0
2) Auto Tracking is performed.
05-4. DVI Selector
1) Press POWER OFF button.
INFO
S-VIDEO
5
INFO
AUTO
FUNCTION
PDP
REMOTE CONTROL
ON
2
PC
7
HDSDI
MPDP
BROADCAST
ON
DVI CONVERTER INPUT
VIDEO
4
S-VIDEO
HDMI
1) Press AUTO button.
B
PWR ON
DTV
OFF
A
1
DVI
PC
DVIC1
DVIC2
OUTPUT
2.POWER OFF
ON
DVI CONVERTER INPUT
VIDEO
BROADCAST
ON
0
SET
05-3. AUTO Tracking (PC Mode Only)
1) Press POWER ON button.
OFF
1
B
DVI
1.POWER ON
Infinitely Expandable
BROADCAST
ON
2) W
hen the LED is turned on, MPDP output is DVI 1 and when it is
turned off MPDP output is DVI 2.
DVI CONVERTER INPUT
VIDEO
PC
DTV
S-VIDEO
HDSDI
DVIC1
DVIC2
OUTPUT
HDMI
INFO
AUTO
FUNCTION
MPDP
1) Press BROADCAST button.
PDP
REMOTE CONTROL
OFF
DVI 1
9
PDP
DVI 2
REMOTE
0 CONTROL
SET
HOR
A
2) W
hen the LED dot in the 7-segment at the lower left side unit is
turned on, Broadcast command is executed.
B
INFO
VER
DVI
DVI CONVERTER INPUT
VIDEO
PC
DTV
S-VIDEO
HDSDI
HDMI
10 | ORION CO., LTD.
DVIC1
DVIC2
OUTPUT
INFO
AUTO
FUNCTION
MPDP
ORION CO., LTD. | 11
New Multi Function Controller
Infinitely Expandable
05-5. Mode change
There are four interface, Ethernet, USB, RS-232C, and IR (Remote control).
Users can select the mode
Press one of the four LED switches to select a mode you want.
1.IR mode
IR interface is designed to execute some MPDP commands through the wireless infrared
communication. It includes some tests and functions to configure Ethernet settings. The
signal from the remote controller is converted to RS-232C signal as defined in the protocol
and send to MPDP.
2.Ethernet mode
Ethernet interface is based on TCP/IP Protocol. According to DHCP setting, it can be
used as dynamic IP or static IP. Long distance control with World Wide Web and internet
communication through HUB or Switch are available.
1) To execute Ethernet mode, press Ethernet LED switch on the front side of New MFC
2) T
o control MPDP, connect to a computer and use MSCS program.
(Corresponding port should be selected)
1) To execute IR mode, press IR LED switch on the front side of New MFC.
2) When you press, IR LED switch, the other communication modes are not working.
DVI-D_1
3) F
or better IR performance, MPDP set configuration is necessary. Configure the number
of "X" and "Y" as installed.
DVI-D_1
DVI-D_1
RS-232C
OUTPUT
OUTPUT
INPUT
OUTPUT
ID 1
RS-232C
OUTPUT
INPUT
OUTPUT
OUTPUT
OUTPUT
INPUT
INPUT
OUTPUT
INPUT
ID 2
INPUT
ID 3
INPUT
DVI-D_1
RS-232C
DVI-D_1
RS-232C
INPUT
OUTPUT
OUTPUT
OUTPUT
INPUT
RS-232C
OUTPUT
PWR ON
OUTPUT
INPUT
IR
ETHERNET
VER
ID 4
VER
INPUT
INPUT
DVI-D_1
IR
DVI
ID 5
OUTPUT
OUTPUT
INPUT
OUTPUT
ID 3
OUTPUT
INPUT
INPUT
DVI-D_1
RS-232C
OUTPUT
OUTPUT
INPUT
OUTPUT
INPUT
ID 5
INPUT
OUTPUT
INPUT
ID 6
DVI-D_1
RS-232C
OUTPUT
INPUT
DVI-D_1
OUTPUT
INPUT
RS-232C
OUTPUT
OUTPUT
INPUT
OUTPUT
VIDEO
S-VIDEO
RS-232C
OUTPUT
INPUT
DVI-D_1
RS-232C
DVI 1/2
DTV
INPUT
DVI-D_1
RS-232C
INPUT
OUTPUT
ID 6
DVI-D_1
RS-232C
DVI 1/2
DTV
OUTPUT
RS-232C
OUTPUT
DVI-D_1
IR
PWR OFF
HOR
PC
INPUT
ID 4
HOR
OUTPUT
PC
ETHERNET
OUTPUT
PWR OFF
DVI
IR
RS-232C
INPUT
DVI-D_1
OUTPUT
PWR ON
DVI-D_1
INPUT
ID 2
RS-232C
ID 1
DVI-D_1
RS-232C
DVI-D_1
RS-232C
INPUT
OUTPUT
DVI-D_1
RS-232C
OUTPUT
INPUT
OUTPUT
RS232
USB
HDSDI
DVIC1
HDMI
DVIC2
ID 7
INPUT
ID 8
INPUT
ID 9
INPUT
VIDEO
S-VIDEO
RS232
USB
HDSDI
DVIC1
HDMI
DVIC2
IR
ETHERNET
RS232
USB
ID 7
INPUT
ID 8
INPUT
ID 9
IR
ETHERNET
RS232
USB
INPUT
RS-232C
New MFC
RS-232C
DVI Signal Distributor
(UXGA : UP TO 165MHz)
New MFC
Ethernet
DVI Signal Distributor
(UXGA : UP TO 165MHz)
ON
OFF
ID SETTING
1
2
3
4
5
6
7
8
9
HUB or Router
(Wireless & Cable)
OFF
DVI 1
DVI 2
0
SET
BROADCAST
ON
A
MSCS control PC
B
INFO
DVI
DVI CONVERTER INPUT
VIDEO
PC
DTV
S-VIDEO
HDSDI
DVIC1
DVIC2
OUTPUT
12 | ORION CO., LTD.
HDMI
INFO
AUTO
FUNCTION
MPDP
PDP
REMOTE CONTROL
ORION CO., LTD. | 13
Remote Controller
New Multi Function Controller
ON
ID SETTING
„„IP address
Infinitely Expandable
OFF
1
2
3
4
5
6
BROADCAST
ON
OFF
DVI 1
1) Change to IR mode and press
buttons in the remote controller sequentially.
7
8B→B→A→A
9
IR
DVI 2
0
ETHERNET
SET
A
B
INFO
RS232
USB
DVI
DVI CONVERTER INPUT
PC
DTV
HDMI
2) When the two LED dots in upper 7-segment are turned on, test mode is started.
VIDEO
HOR
VER
S-VIDEO
DVIC1
DVIC2
OUTPUT
HDSDI
INFO
AUTO
FUNCTION
MPDP
PDP
REMOTE CONTROL
3) Load the provided program by executing "PIC Configuration.exe" in your computer.
A status window is popped up as shown in the following picture.(Serial port cable must
be connected)
4) Match the Com Port and press "OPEN" and click "Test for MFC"
14 | ORION CO., LTD.
ORION CO., LTD. | 15
New Multi Function Controller
5) Type IP address and press "Set TCP/IP Info"
Infinitely Expandable
3.Serial mode
Serial communication is performed based on RS-232C specification. New MFC allows
long distance communication by compensating communication signals, because the signal
strength may be decreased by daisy chain connection.
1) To execute Serial mode, press RS-232C LED switch on the front side of New MFC
2) T
o control MPDP, connect to a computer and use MSCS program.
(Corresponding port should be selected)
DVI-D_1
DVI-D_1
RS-232C
OUTPUT
INPUT
ID 1
OUTPUT
INPUT
OUTPUT
INPUT
ID 2
PWR ON
IR
ETHERNET
6) Press "Get TCP/IP Info" and check the IP address.
INPUT
OUTPUT
OUTPUT
ID 3
OUTPUT
INPUT
OUTPUT
INPUT
DVI-D_1
DVI-D_1
RS-232C
OUTPUT
INPUT
RS-232C
OUTPUT
OUTPUT
INPUT
OUTPUT
PWR OFF
ID 4
HOR
VER
INPUT
INPUT
OUTPUT
INPUT
ID 6
DVI-D_1
RS-232C
OUTPUT
INPUT
DVI-D_1
RS-232C
DVI 1/2
DTV
ID 5
DVI-D_1
IR
DVI
PC
RS-232C
INPUT
DVI-D_1
RS-232C
OUTPUT
DVI-D_1
RS-232C
OUTPUT
INPUT
RS-232C
OUTPUT
OUTPUT
INPUT
OUTPUT
VIDEO
S-VIDEO
RS232
USB
HDSDI
DVIC1
HDMI
DVIC2
IR
ETHERNET
RS232
USB
ID 7
INPUT
ID 8
INPUT
ID 9
INPUT
RS-232C
New MFC
DVI Signal Distributor
(UXGA : UP TO 165MHz)
RS-232C
MSCS control PC
16 | ORION CO., LTD.
ORION CO., LTD. | 17
New Multi Function Controller
Infinitely Expandable
4.USB mode
„„How to install USB driver
USB communication is performed based on RS-232C specification too. The external
interface is USB type and it is converted to RS-232C internally.
1) Download a proper driver that fits FT232R type from http://www.ftdichip.com/Drivers/
VCP.htm.
1) To execute USB mode, press USB LED switch on the front side of New MFC
2) Unzip the downloaded file, "CDM 2.04.16 WHQL Certified.zip"
2) To control MPDP, connect to a computer with USB cable and use MSCS program.
(Corresponding port should be selected)
3) When the New MFC and a computer is connected, it searches the driver for a new
device. Set the path to the folder that the unzipped file is saved and start driver
installation.
DVI-D_1
DVI-D_1
RS-232C
OUTPUT
INPUT
ID 1
OUTPUT
INPUT
OUTPUT
INPUT
ID 2
PWR ON
IR
ETHERNET
INPUT
OUTPUT
OUTPUT
ID 3
OUTPUT
INPUT
OUTPUT
INPUT
DVI-D_1
DVI-D_1
RS-232C
OUTPUT
INPUT
RS-232C
OUTPUT
OUTPUT
INPUT
OUTPUT
PWR OFF
ID 4
HOR
VER
INPUT
INPUT
OUTPUT
INPUT
ID 6
DVI-D_1
RS-232C
OUTPUT
INPUT
DVI-D_1
RS-232C
DVI 1/2
DTV
ID 5
DVI-D_1
IR
DVI
PC
RS-232C
INPUT
DVI-D_1
RS-232C
OUTPUT
DVI-D_1
RS-232C
4) "USB Serial Port" is registered at the Control panel. The communication port number is
shown as "COM23", The number of each USB port may be changed.
OUTPUT
INPUT
RS-232C
OUTPUT
OUTPUT
INPUT
OUTPUT
VIDEO
S-VIDEO
RS232
USB
HDSDI
DVIC1
HDMI
DVIC2
IR
ETHERNET
RS232
USB
ID 7
INPUT
ID 8
INPUT
ID 9
INPUT
RS-232C
New MFC
DVI Signal Distributor
(UXGA : UP TO 165MHz)
USB
MSCS control PC
18 | ORION CO., LTD.
ORION CO., LTD. | 19
New Multi Function Controller
Infinitely Expandable
ON
ID SETTING
05-6. Input Selection
OFF
1
2
3
4
5
6
7
8
9
It receives Computer, HDMI, DTV, VIDEO, S-VIDEO, DVI, and HDSDI as input
source, converts to DVI and sends to MPDP.
1) When the input source of the DVI converter is selected by MSCS program on the
computer or the remote controller of New MFC, the corresponding LED is turned on.
DVI 2
0
SET
A
B
INFO
1.DVI
ON
DVI
1
OFF
BROADCAST
DVI CONVERTER INPUT
ON
PC
DTV
HDMI
2
3
VIDEO
S-VIDEO
HDSDI
7
8
4
5
DVIC1
DVIC2
OUTPUT
RS-232C
ID 2
INPUT
DVI-D_1
PWR ON
INPUT
INPUT
ID 3
INPUT
DVI-D_1
RS-232C
OUTPUT
OUTPUT
INPUT
RS-232C
OUTPUT
OUTPUT
INPUT
ID 4
VER
INPUT
ID 5
INPUT
DVI-D_1
IR
DVI
RS-232C
DVI 1/2
DTV
OUTPUT
INPUT
ID 6
OUTPUT
INPUT
DVI-D_1
DVI-D_1
RS-232C
OUTPUT
OUTPUT
INPUT
OUTPUT
INPUT
1
OFF
BROADCAST
DVI CONVERTER INPUT
ON
PC
DTV
HDMI
2
3
VIDEO
S-VIDEO
HDSDI
7
8
4
5
DVIC1
DVIC2
OUTPUT
6
9
SET
1) Press PC button.
OFF
DVI 1
INFO
AUTO
FUNCTION
DVI 2
0 PC
MPDP
A
2) PC LED is on.
B
PDP
REMOTEINFO
CONTROL
OUTPUT
3.DTV
INPUT
DVI
RS-232C
OUTPUT
DVI
OUTPUT
PWR OFF
HOR
PC
OUTPUT
DVI-D_1
RS-232C
OUTPUT
RS-232C
OUTPUT
ID SETTING
INPUT
INPUT
2) DVI LED is on.
B
DVI-D_1
RS-232C
OUTPUT
OUTPUT
DVI 1
INFO
AUTO
FUNCTION
DVI 2
PDP
REMOTEINFO
CONTROL
ON
DVI-D_1
9
1) Press DVI button.
OFF
A
2.PC
DVI-D_1
6
0 DVI
MPDP
SET
2) Two outputs of the DVI converter can be selected and the corresponding LEDs are
turned on.
ID 1
DVI 1
All inputs are executed as full screen mode.
ID SETTING
New MFC is designed to control the input sources of DVI converter easily.
INPUT
OFF
„„Input Selection
This function is used for a DVI converter, sold separately. It indicates various
inputs and outputs with a DVI converter.
OUTPUT
BROADCAST
ON
VIDEO
S-VIDEO
HDSDI
DVIC1
HDMI
DVIC2
ID 7
INPUT
ID 8
INPUT
ID 9
DVI CONVERTER INPUT
VIDEO
IR
ETHERNET
RS232
USB
New MFC
PC
DTV
S-VIDEO
HDSDI
DVIC1
DVIC2
OUTPUT
RS-232C
HDMI
INFO
AUTO
FUNCTION
DTV
MPDP
DVI Signal Distributor
(UXGA : UP TO 165MHz)
RS-232C
DVI converter
1) Press DTV button.
2) DTV LED is on.
PDP
REMOTE CONTROL
Video Signal
RS-232C
MSCS control PC
20 | ORION CO., LTD.
ORION CO., LTD. | 21
ON
OFF
New Multi Function Controller
ID SETTING
1
2
3
4
5
6
7
8
9
OFF
DVI 1
DVI 2
0
SET
Infinitely Expandable
BROADCAST
ON
A
B
ON
INFO
05-7.
X x3 Y Configuration
1
2
4.VIDEO
ON
BROADCAST
ON
OFF
DVI CONVERTER INPUT
PC
DTV
HDMI
VIDEO
S-VIDEO
HDSDI
BROADCAST
ON
4
5
6
7
8VIDEO9
1
2
3
ID SETTING
DVIC1
DVIC2
OUTPUT
0
SET
4
5
6
7
8
9
(e.g. Horizontal 5 sets x Vertical 6 sets)
OFF
„„Horizontal configuration
OFF
INFO
AUTO
DVI 1
FUNCTION
MPDP
1) Press VIDEO button.
ID SETTING
DVI
OFF
DVI 2
0
SET
2) VIDEO LED is on.
DVI 1
A
DVI 2
B
1) Press SET button.
2) Press Left and Right buttons sequentially to enter the horizontal
configuration mode.
INFO
PDP
REMOTE CONTROLB
A
OFF
5.S-VIDEO
1
DVI
BROADCAST
ON
DVI CONVERTER INPUT
ID SETTING
2
PC
3
DTV
VIDEO
4
S-VIDEO
5
HDSDI
6
7
8
9
DVIC1
DVIC2
OUTPUT0
HDMI
PC
DTV
VIDEO
S-VIDEO
HDSDI
DVIC1
DVIC2
A
INFO
AUTO
FUNCTION
HOROUTPUT
MPDP
DVI 1
INFO
AUTO
DVI
2
FUNCTION
2) S-VIDEO LED is on.
PDP
REMOTE CONTROL
ON
OFF
PDP
INFO
ON
OFF
REMOTE
CONTROL
6.HDSDI
ID SETTING
2
PC
3
DTV
VIDEO
4
S-VIDEO
5
HDSDI
6
7
8
9
DVIC1
DVIC2
OUTPUT0
HDMI
OFF
DVI 1
INFO
AUTO
DVI
2
FUNCTION
HDSDI
MPDP
SET
1) Press HDSDI button.
ID SETTING
1
DVI
1
2
3
4
5
6
7
8
9
OFF
DVI 1
DVI 2
0
SET
2) HDSDI LED is on.
BROADCAST
ON
A
A
B
3) When the 2 LEDs at lower right corner of each 7-segment of
Horizontal line in the New MFC are turned on, the horizontal
configuration mode is started.
VER
B
BROADCAST
ON
DVI CONVERTER INPUT
HDMI
1) Press S-VIDEO button.
OFF
S-VIDEO
MPDP
SET
DVI CONVERTER INPUT
DVI
INFO
ON
4) U
se the number buttons to set the numbers of MPDP sets in
horizontal line.
-e.g. If you want to set 5 for horizontal number, press "0" for the
tens digit and "5" for the units digit.
B
HOR
INFO
PDP
INFO
REMOTE CONTROL
7.HDMI
DVI
DVI CONVERTER INPUT
VIDEO
PC
DTV
S-VIDEO
HDSDI
INFO
AUTO
FUNCTION
HDMI
MPDP
PDP
REMOTE CONTROL
22 | ORION CO., LTD.
ON
OFFINPUT
DVI CONVERTER
PC
2) HDMI LED is on.
DTV
S-VIDEO
4
5
7
8MPDP
9
2
3
6
DVIC1
DVIC2
OUTPUT
OFF
INFO
AUTO
FUNCTION
DVI 1
0
SET
HDMI
BROADCAST
HDSDI
ON
VIDEO
1
ID SETTING
DVIC1
DVIC2
OUTPUT
HDMI
1) Press HDMI button.
DVI
VER
DVI 2
5) Press SET button to finish the horizontal configuration mode.
PDP
CONTROLB
AREMOTE
INFO
DVI
DVI CONVERTER INPUT
VIDEO
PC
DTV
S-VIDEO
HDSDI
HDMI
ORION CO., LTD. | 23
New Multi Function Controller
ON
05-8. BIC control Setting
OFF
ID SETTING
1
2
3
4
5
6
7
8
9
BROADCAST
ON
OFF
„„Vertical configuration
SET
DVI 1
DVI 2
0
Infinitely Expandable
A
B
1) Press SET button.
2) Press Up and Down buttons sequentially to enter the vertical
configuration mode.
(Only applicable to OPM-4250, OPM-4250R)
BIC (Burn-In Compensation) function is to reduce the visible burn-in
effect on the screen by the communication with MPDP through New
MFC.
1) There is BIC On/Off switch on the main board for BIC Control Setting.
(See the white circle lower right corner of the following picture)
INFO
DVI CONVERTER INPUT
DVI
PC
DTV
VIDEO
S-VIDEO
HDSDI
DVIC1
DVIC2
HDMI
INFO
AUTO
FUNCTION
HOROUTPUT
MPDP
3) When the 2 LEDs at lower right corner of each 7-segment
of Vertical line in the New MFC are turned on, the vertical
configuration mode is started.
2) To turn on BIC, move the pin No.1 of the SW6 to On side.
VER
PDP
REMOTE CONTROL
ON
ID SETTING
1
2
3
4
5
6
7
8
9
BROADCAST
ON
OFF
DVI 1
DVI 2
0
SET
A
4) U
se the number buttons to set the numbers of MPDP sets in
Vertical line.
-e.g. If you want to set 6 for vertical number, press "0" for the
tens digit and "6" for the units digit.
KSD52S
ON
HOR
BA1 2
3
BIC ON
4
5
BA1 2
3
4
5
BIC OFF
3) When the LED dot in the lower right side of 7-segment is turned on, BIC is
started.
B
DVI
KSD52S
ON
OFF
INFO
HOR
ON
OFFINPUT
DVI CONVERTER
PC
DTV
HDMI
VIDEO
S-VIDEO
HDSDI
BROADCAST
ON
4
5
7
8MPDP
9
VER
1
2
3
ID SETTING
6
DVIC1
DVIC2
OUTPUT
SET
VER
OFF
INFO
AUTO
FUNCTION
DVI 1
0
DVI 2
5) Press SET button to finish the vertical configuration mode.
PDP
CONTROLB
AREMOTE
INFO
24 | ORION
LTD.
DVI CO.,
CONVERTER
INPUT
DVI
PC
DTV
VIDEO
S-VIDEO
HDSDI
HDMI
ORION CO., LTD. | 25
New Multi Function Controller
Infinitely Expandable
06. Before calling for service
05-9. Baud-Rate Configuration
1) New MFC can be used as a communicational distributor for any devices with its various
communicational speeds.
Before calling for service, check the following and then contact the dealership
where you purchased this product.
2) To configure the baud-rate, adjust the baud-rate switch(SW6), which is circled at the
lower right corner of the following picture.
1. N
ew MFC is not turned off even after MPDP power cable is
disconnected.
-N
ew MFC and MPDP set work with the independent power supplies.
When you need to turn on the MPDP again, please connect power cable and press
"ON" button in the New MFC.
- If you want to turn off New MFC, please disconnect the power cable of the New MFC.
2. New MFC does not work with no reason.
Please disconnect and reconnect the adapter.
- Please replace batteries of the remote controller.
* SW6 is used for BIC on/off (Pin No.1) and baud-rated configuration (Pin No.3~5) commonly.
3) Baud-Rate Configuration
3pin
Switch (SW6) - 3,4,5
4pin
9600bps
On
On
-
19200bps
Off
On
-
Mode
Daisy-chain In
Daisy-chain Out
26 | ORION CO., LTD.
5pin
57600bps
On
Off
115200bps
Off
Off
-
9600bps
-
-
On
115200bps
-
-
Off
ORION CO., LTD. | 27
New Multi Function Controller
Infinitely Expandable
07. Specification
Product Name
Remote Controller
NEW MFC
Adapter
MEMO
Specification
Name
MPDP REMOTE CONTROL
Power
1.5V Battery(AAA) 2EA
Size
55(W) x 190(L) x 25(H) mm
Environmental Condition
-10℃ ~ 40℃
Weight
130g
Voltage
+5~9V(DC), 1.25W (MAX)
Power Consumption
250mA(Max, +5~9V)
Size
58(W) x 216(L) x 46(H) mm
Environmental Condition
0℃ ~ 40℃, 20 ~80% RH
Weight
480g
Size
35(W) x 80(L) x 86(H) mm
Input
90~264V(47~63Hz)
Output
5V, 2000mA
Output Jack
2.1φ(Internal diameter):Vcc, 5.5φ(External diameter):GND
Input/Output Specification
NEW MFC
Terminal Name
RS-232C
Control Input
Terminal Specification
D-Sub 9Pin (Female)
Baud Rate : 115200
Ethernet
RJ-45
TCP/IP
USB
Type B
USB2.0
IR
Max 15m, left/right 45°(standard : 3m)
Key Button
Control Mode Select (IR / Ethernet / RS-232C / USB)
Control Output
RS-232C (4ea)
D-Sub 9Pin (Male)
Baud Rate : 115200
Max ±15V
MPDP ID Setting
7-Segment LED
1~99
MPDP Horizontal Number,
Vertical Number
- Minimum interval between button input: 0.6 second
※ Specification can be changed without prior notice to improve product quality.
28 | ORION CO., LTD.
ORION CO., LTD. | 29
New Multi Function Controller
MEMO
30 | ORION CO., LTD.