Download OPM-4260 MFC User Manual
Transcript
New Multi Function Controller ON OFF ID SETTING 1 2 3 4 5 6 7 8 9 OFF DVI 1 DVI 2 0 SET BROADCAST ON A B ORION CO., LTD. INFO www.oriondisplay.net DVI DVI CONVERTER INPUT VIDEO Address: 257-6, Gongdan-dong, Gumi-si, Gyeongsangbuk-do, Korea Tel : +82-2-6678-8533, Fax: +82-2-6678-8599 PC DTV S-VIDEO HDSDI DVIC1 DVIC2 OUTPUT HDMI INFO AUTO FUNCTION MPDP PDP REMOTE CONTROL • 2011.09.30 User's Manual Thank you for purchasing our New Multi Function Controller. Please read through this user's manual for safety before installing this product. This product is manufactured for Multi Plasma display model only. New Multi Function Controller Infinitely Expandable Product & Accessary Contents Please check remote controller and all the accessories are included in the box ON ID SETTING 1 2 3 5 6 7 8 9 SET BROADCAST ON 02. Product Introduction................................................................4 OFF Introduction.......................................................................................4 DVI 1 DVI 2 0 Features.............................................................................................4 A B Advantages .....................................................................................4 INFO DVI 03. User Guide Information..........................................................5 DVI CONVERTER INPUT VIDEO Cautions for New MFC..................................................................2 Cautions for Adapter......................................................................3 OFF 4 01. Safety Precautions...................................................................2 PC DTV S-VIDEO HDSDI DVIC1 DVIC2 OUTPUT HDMI Remote Controller............................................................................5 INFO AUTO FUNCTION New MFC..........................................................................................6 MPDP 04. New MFC Installation..............................................................8 PDP REMOTE CONTROL 05. How to use Remote Controller........................................ 10 Remote Controller : 1EA Multi Function Controller : 1EA 05-1. Power ON/OFF .............................................................. 10 05-2. BROADCAST ................................................................... 10 05-3. AUTO Tracking (PC Mode Only)................................. 11 05-4. DVI Selector...................................................................... 11 05-5. Mode change................................................................... 12 05-6. Input Selection ................................................................ 20 05-7. X x Y Configuration (e.g. Horizontal 5 sets x Vertical 6 sets)............23 Manual : 1EA RS-232C Cable : 1EA Battery (AAA) : 2EA 05-8. BIC control Setting (Only applicable to OPM-4250, OPM-4250R)....... 25 05-9. Baud-Rate Configuration.............................................. 26 06. Before calling for service................................................... 27 07. Specification............................................................................ 28 L-Bracket : 2EA Adapter 1EA box 1EA ORION CO., LTD. | 1 New Multi Function Controller Infinitely Expandable 01. Safety Precautions Cautions for New MFC Please do not use at the places of hot and humid environment. - It may damage the product. Do not touch the power cable with wet hands. - It may cause an electric shock. Cautions for Adapter Do not store or use flammables like a combustible spray around the product. - It has a possible danger of explosion or fire. Do not put the product under the direct sunlight or near to hot places. - It may cause fire. Do not spray water directly on the product. - It may cause an electric shock or fire. Please be careful not to soak unknown material or liquid into the product. - It may damage the product. Do not disassemble, repair or alter the product with users' own intention. - It may cause an electric shock or fire. If you need to test, adjust or repair the product, contact with an authorized service center. If you detect smoke, smell or strange sound from the product, stop using the product immediately, disconnect the power cable and contact with an authorized service center. Use the provided adapter - Improper adapters may damage the product. If you cannot use the provided adapter, use the adapter of proper specification. - It may cause an electric shock. Do not put a heavy object on the Do not connect to a multicable or fold the cable. power-socket together with many other electric products. - It may cause an electric shock or fire. Make sure the power plug is properly connected. - Loose connection may cause an electric shock. Disconnect the power plug on the occasion of lightning. - It may damage the product. - It may cause an electric shock or fire. - It may cause an electric shock or fire. Carefully move the product not to Please do not stack heavy give any shock. objects on top of the product. - It may cause product malfunction. - It may damage the product. Please keep away from children's reach. Notice to users - If they drop Remote Controller, it may hurt the children or cause product malfunction. Class A digital device Warning 2 | ORION CO., LTD. Do not touch the adapter with wet hands. It is a device designed for business purpose with a safety certificate for electromagnetic interference, which user should be mindful of. ORION CO., LTD. | 3 New Multi Function Controller Infinitely Expandable 02. Product Introduction 03. User Guide Information Introduction Remote Controller New MFC (Multi Function Controller) is designed for functional expansion and compensation in communication and users’ convenience. It provides various communicational interfaces OFF Turn on/off MPDP. ID Setting 1 2 3 Set the number of MPDP in horizontal and vertical positions. (XxY) 4 5 6 7 8 9 X x Y Setting Features MPDP is mainly controlled through the Serial communication (RS-232C). However, gradually, USB and Ethernet port are replacing Serial port in control devices such as computers. New MFC can support either case. Based on installation circumstance or Users’ preference, Serial (RS-232), USB or Ethernet can be selected. Especially, Ethernet allows controlling MPDP through LAN network or even with Internet. Users can have better communication quality with 4-channel serial port equipped in a New MFC. It helps avoiding possible undesirable communicational distortion from multiple daisy-chains. ON POWER ON/OFF Enter X x Y setting mode. ID SETTING of Serial, USB and Ethernet and also provides 4-channel daisy chain port to solve the most critical problem of serial communication. Users can find out the status of the product with the LED indicators. It is also functioning as a BIC controller and a receiver for Remotecontroller. OFF DVI 1 DVI 2 0 SET BROADCAST ON B DVI DVI Converter Output Advantages Function A / B DVI CONVERTER INPUT VIDEO Select DVI Converter output, DVIC1 or DVIC2. MPDP Input select Enter to the test mode of New MFC INFO Select directions to set the number of MPDP (horizontal or vertical) and check the status of MPDP. Broadcast is the function to control all MPDP sets at once. It is applied for Power On/Off and Auto tracking. Select DVI input of MPDP, DVI 1 or DVI 2. A Direct & Info key Broadcast PC DTV S-VIDEO HDSDI DVIC1 DVIC2 OUTPUT HDMI INFO AUTO FUNCTION MPDP DVI Converter Input Select Select source input for DVI converter. DVI Converter INFO / AUTO Check the current status information of DVI converter and execute Auto tracking. PDP REMOTE CONTROL 1. Expand the communicational functions of MPDP. (Serial / USB / Ethernet / IR) 2. Prevent possible communicational distortion from using Serial port by 4-channel serial port. 3. It transmits the information for BIC by communicating with MPDP without additional applications. (Only applicable to OPM-4250, OPM-4250R) 4. Control the main functions of MPDP and DVI converter by a remote controller without additional applications. 4 | ORION CO., LTD. 1.Note : 2.How to mount batteries Use two 1.5V AAA-type batteries. Do not mix old and new batteries, Do not mix different types or makes of batteries. Mixed use of Alkaline, Manganese or Re-chargeable batteries are NOT recommended. Only use two batteries of the same type and make. Slide the cap at the rear side of the remote controller to open. Insert batteries with the correct polarity and close the cap. ORION CO., LTD. | 5 New Multi Function Controller Infinitely Expandable New MFC D 1.Front side E G 2.Rear side A A B C F B C D E F H A.Power On Indicator It is turned on when "Power-On" command is received from the remote-controller. B.Power Off Indicator It is turned on when "Power-Off" command is received from the remote-controller. C.MPDP configuration Indicator It indicates the configuration of "X x Y" in the 7-segments. D.IrDA Receiver It is the reception position for the IR signal from the remote-Controller. E. Indicator for DVI Input selection of MPDP It is turned on for "DVI1 channel" and turned off for "DVI2 channel". F. Input Mode Indicator It indicates the current input source. G.DVI Converter DVI Output Indicator A.Power connector Power connection for 5~9V B.Service Port It is a port for program download and debugging. C.USB Port (Type B) It is used for communication when the interface is changed to USB mode. D.Ethernet Port If it is directly connected to an external control device, "Crossover Network Cable" must be used. If it is connected to a hub, "Straight-Through Network Cable" must be used. E. 1 Channel Serial Port (R/A 9pin DSUB-female) It is a connection port between Main board and sub board. F. 4-Channel daisy-chain Serial Port (R/A 9pin DSUB-male) It is used to connect with MPDP. Each channel can used to connect 25 MPDP daisy-chain. It indicates the current DVI output. H.Converting switch and indicator for communication Interface They are push button switches and indicators for communication interface (Serial/IR/USB/Ethernet). 6 | ORION CO., LTD. ORION CO., LTD. | 7 New Multi Function Controller Infinitely Expandable 04. New MFC Installation DVI-D_1 OUTPUT 1. C onnect RS-232C cable and a power adapter and install at the location of good remote control reception. Use L-brackets to install at the side of the set. 2.Connect a computer and the New MFC with at least one of Ethernet, RS-232C, and USB port and connect the MPDP to the RS-232C output in the New MFC. Users can control MPDP with one of Ethernet, RS-232, USB, and IR remote controller. 3. S et the number of MPDP units as instructed in <Configuration Mode> in the manual. (Initial setting is 3X3) 4. T he LED lamps in the New MFC indicate the previous or initial input source at first, please select input source once again after power supply. (Default; previous input source). ※Caution : P lease do not directly expose the IrDA Receiver to fluorescent lamps. It may cause malfunction. DVI-D_1 RS-232C INPUT ID 1 RS-232C INPUT OUTPUT OUTPUT INPUT ID 4 ID 7 DVI-D_1 RS-232C INPUT OUTPUT OUTPUT OUTPUT INPUT DVI-D_1 RS-232C INPUT INPUT ID 6 INPUT DVI-D_1 INPUT OUTPUT OUTPUT ID 5 RS-232C OUTPUT DVI-D_1 RS-232C INPUT OUTPUT OUTPUT OUTPUT INPUT DVI-D_1 RS-232C INPUT INPUT ID 3 INPUT DVI-D_1 INPUT OUTPUT OUTPUT ID 2 RS-232C OUTPUT DVI-D_1 RS-232C OUTPUT OUTPUT ID 8 ID 9 INPUT L-Bracket PWR ON INPUT OUTPUT INPUT PWR OFF RS-232C HOR VER IR DVI PC DVI 1/2 DTV RS-232C DVI Signal Distributor (UXGA : UP TO 165MHz) VIDEO S-VIDEO USB Ethernet HDSDI DVIC1 HDMI DVIC2 IR ETHERNET RS232 USB MSCS control PC New MFC New MFC Video Source ON OFF 1 ID SE 4 ING TT 7 2 5 SE 8 0 T 9 INFO I CO NV ER PC TE I O S-VI DT DE O DV IC1 OU TP DVIC 2 UT MP DP RE AS T F I1 I2 B DV DV VIDE OA DC ON OF DV DV A BR 3 6 INFO FU NC R IN V HD SD I PU T HD MI AU TION TO MO P TE DP CO NT RO L 8 | ORION CO., LTD. Remote Controller ORION CO., LTD. | 9 ON New Multi Function Controller ID SETTING 05. How to use Remote Controller OFF 1 2 3 4 5 6 7 8 9 OFF DVI 1 DVI 2 0 SET A 05-1. Power ON/OFF Every command is executed on all MPDP sets. ON 3 4 5 6 PWR ON 8 9 ID SETTING 2 7 INFO It is available only with PC mode. When it is connected with DVI converter, Auto Tracking is used to correct the distorted screen alignment. DVI 1 PWR OFF DVI 2 2) MPDP is turned on as the PWR LED of the New MFC is turned on. 3 DTV ID SETTING DVI 1 PWR OFF 8 1 2 3 4 5 6 7 8 9 HDMI OFF HDSDI 6 9 INFO AUTO DVI 2 FUNCTION 2) MPDP is turned off as the PWR LED of the New MFC is turned off. A SET 05-2. BROADCAST BROADCAST is a command to make all MPDP perform Power On, Off or Auto Tracking simultaneously. DVI CONVERTER INPUT VIDEO S-VIDEO ON HDMI HDSDI OFF BROADCAST ON INFO AUTO 3FUNCTION DVIC1 DVIC2 1OUTPUT2 ID SETTING MPDP 4 5 7 8 6 DVI 1 B INFO PDP INFO REMOTE CONTROL DTV OFF A B PC BROADCAST ON DVI 1) Press DVI 1 or DVI 2 buttons in the Remote controller. DVI 2 0 MPDP SET DVI OFF It is used to select DVI 1 input or DVI 2 input. ID SETTING OFF DVIC1 DVIC2 OUTPUT0 2) Auto Tracking is performed. 05-4. DVI Selector 1) Press POWER OFF button. INFO S-VIDEO 5 INFO AUTO FUNCTION PDP REMOTE CONTROL ON 2 PC 7 HDSDI MPDP BROADCAST ON DVI CONVERTER INPUT VIDEO 4 S-VIDEO HDMI 1) Press AUTO button. B PWR ON DTV OFF A 1 DVI PC DVIC1 DVIC2 OUTPUT 2.POWER OFF ON DVI CONVERTER INPUT VIDEO BROADCAST ON 0 SET 05-3. AUTO Tracking (PC Mode Only) 1) Press POWER ON button. OFF 1 B DVI 1.POWER ON Infinitely Expandable BROADCAST ON 2) W hen the LED is turned on, MPDP output is DVI 1 and when it is turned off MPDP output is DVI 2. DVI CONVERTER INPUT VIDEO PC DTV S-VIDEO HDSDI DVIC1 DVIC2 OUTPUT HDMI INFO AUTO FUNCTION MPDP 1) Press BROADCAST button. PDP REMOTE CONTROL OFF DVI 1 9 PDP DVI 2 REMOTE 0 CONTROL SET HOR A 2) W hen the LED dot in the 7-segment at the lower left side unit is turned on, Broadcast command is executed. B INFO VER DVI DVI CONVERTER INPUT VIDEO PC DTV S-VIDEO HDSDI HDMI 10 | ORION CO., LTD. DVIC1 DVIC2 OUTPUT INFO AUTO FUNCTION MPDP ORION CO., LTD. | 11 New Multi Function Controller Infinitely Expandable 05-5. Mode change There are four interface, Ethernet, USB, RS-232C, and IR (Remote control). Users can select the mode Press one of the four LED switches to select a mode you want. 1.IR mode IR interface is designed to execute some MPDP commands through the wireless infrared communication. It includes some tests and functions to configure Ethernet settings. The signal from the remote controller is converted to RS-232C signal as defined in the protocol and send to MPDP. 2.Ethernet mode Ethernet interface is based on TCP/IP Protocol. According to DHCP setting, it can be used as dynamic IP or static IP. Long distance control with World Wide Web and internet communication through HUB or Switch are available. 1) To execute Ethernet mode, press Ethernet LED switch on the front side of New MFC 2) T o control MPDP, connect to a computer and use MSCS program. (Corresponding port should be selected) 1) To execute IR mode, press IR LED switch on the front side of New MFC. 2) When you press, IR LED switch, the other communication modes are not working. DVI-D_1 3) F or better IR performance, MPDP set configuration is necessary. Configure the number of "X" and "Y" as installed. DVI-D_1 DVI-D_1 RS-232C OUTPUT OUTPUT INPUT OUTPUT ID 1 RS-232C OUTPUT INPUT OUTPUT OUTPUT OUTPUT INPUT INPUT OUTPUT INPUT ID 2 INPUT ID 3 INPUT DVI-D_1 RS-232C DVI-D_1 RS-232C INPUT OUTPUT OUTPUT OUTPUT INPUT RS-232C OUTPUT PWR ON OUTPUT INPUT IR ETHERNET VER ID 4 VER INPUT INPUT DVI-D_1 IR DVI ID 5 OUTPUT OUTPUT INPUT OUTPUT ID 3 OUTPUT INPUT INPUT DVI-D_1 RS-232C OUTPUT OUTPUT INPUT OUTPUT INPUT ID 5 INPUT OUTPUT INPUT ID 6 DVI-D_1 RS-232C OUTPUT INPUT DVI-D_1 OUTPUT INPUT RS-232C OUTPUT OUTPUT INPUT OUTPUT VIDEO S-VIDEO RS-232C OUTPUT INPUT DVI-D_1 RS-232C DVI 1/2 DTV INPUT DVI-D_1 RS-232C INPUT OUTPUT ID 6 DVI-D_1 RS-232C DVI 1/2 DTV OUTPUT RS-232C OUTPUT DVI-D_1 IR PWR OFF HOR PC INPUT ID 4 HOR OUTPUT PC ETHERNET OUTPUT PWR OFF DVI IR RS-232C INPUT DVI-D_1 OUTPUT PWR ON DVI-D_1 INPUT ID 2 RS-232C ID 1 DVI-D_1 RS-232C DVI-D_1 RS-232C INPUT OUTPUT DVI-D_1 RS-232C OUTPUT INPUT OUTPUT RS232 USB HDSDI DVIC1 HDMI DVIC2 ID 7 INPUT ID 8 INPUT ID 9 INPUT VIDEO S-VIDEO RS232 USB HDSDI DVIC1 HDMI DVIC2 IR ETHERNET RS232 USB ID 7 INPUT ID 8 INPUT ID 9 IR ETHERNET RS232 USB INPUT RS-232C New MFC RS-232C DVI Signal Distributor (UXGA : UP TO 165MHz) New MFC Ethernet DVI Signal Distributor (UXGA : UP TO 165MHz) ON OFF ID SETTING 1 2 3 4 5 6 7 8 9 HUB or Router (Wireless & Cable) OFF DVI 1 DVI 2 0 SET BROADCAST ON A MSCS control PC B INFO DVI DVI CONVERTER INPUT VIDEO PC DTV S-VIDEO HDSDI DVIC1 DVIC2 OUTPUT 12 | ORION CO., LTD. HDMI INFO AUTO FUNCTION MPDP PDP REMOTE CONTROL ORION CO., LTD. | 13 Remote Controller New Multi Function Controller ON ID SETTING IP address Infinitely Expandable OFF 1 2 3 4 5 6 BROADCAST ON OFF DVI 1 1) Change to IR mode and press buttons in the remote controller sequentially. 7 8B→B→A→A 9 IR DVI 2 0 ETHERNET SET A B INFO RS232 USB DVI DVI CONVERTER INPUT PC DTV HDMI 2) When the two LED dots in upper 7-segment are turned on, test mode is started. VIDEO HOR VER S-VIDEO DVIC1 DVIC2 OUTPUT HDSDI INFO AUTO FUNCTION MPDP PDP REMOTE CONTROL 3) Load the provided program by executing "PIC Configuration.exe" in your computer. A status window is popped up as shown in the following picture.(Serial port cable must be connected) 4) Match the Com Port and press "OPEN" and click "Test for MFC" 14 | ORION CO., LTD. ORION CO., LTD. | 15 New Multi Function Controller 5) Type IP address and press "Set TCP/IP Info" Infinitely Expandable 3.Serial mode Serial communication is performed based on RS-232C specification. New MFC allows long distance communication by compensating communication signals, because the signal strength may be decreased by daisy chain connection. 1) To execute Serial mode, press RS-232C LED switch on the front side of New MFC 2) T o control MPDP, connect to a computer and use MSCS program. (Corresponding port should be selected) DVI-D_1 DVI-D_1 RS-232C OUTPUT INPUT ID 1 OUTPUT INPUT OUTPUT INPUT ID 2 PWR ON IR ETHERNET 6) Press "Get TCP/IP Info" and check the IP address. INPUT OUTPUT OUTPUT ID 3 OUTPUT INPUT OUTPUT INPUT DVI-D_1 DVI-D_1 RS-232C OUTPUT INPUT RS-232C OUTPUT OUTPUT INPUT OUTPUT PWR OFF ID 4 HOR VER INPUT INPUT OUTPUT INPUT ID 6 DVI-D_1 RS-232C OUTPUT INPUT DVI-D_1 RS-232C DVI 1/2 DTV ID 5 DVI-D_1 IR DVI PC RS-232C INPUT DVI-D_1 RS-232C OUTPUT DVI-D_1 RS-232C OUTPUT INPUT RS-232C OUTPUT OUTPUT INPUT OUTPUT VIDEO S-VIDEO RS232 USB HDSDI DVIC1 HDMI DVIC2 IR ETHERNET RS232 USB ID 7 INPUT ID 8 INPUT ID 9 INPUT RS-232C New MFC DVI Signal Distributor (UXGA : UP TO 165MHz) RS-232C MSCS control PC 16 | ORION CO., LTD. ORION CO., LTD. | 17 New Multi Function Controller Infinitely Expandable 4.USB mode How to install USB driver USB communication is performed based on RS-232C specification too. The external interface is USB type and it is converted to RS-232C internally. 1) Download a proper driver that fits FT232R type from http://www.ftdichip.com/Drivers/ VCP.htm. 1) To execute USB mode, press USB LED switch on the front side of New MFC 2) Unzip the downloaded file, "CDM 2.04.16 WHQL Certified.zip" 2) To control MPDP, connect to a computer with USB cable and use MSCS program. (Corresponding port should be selected) 3) When the New MFC and a computer is connected, it searches the driver for a new device. Set the path to the folder that the unzipped file is saved and start driver installation. DVI-D_1 DVI-D_1 RS-232C OUTPUT INPUT ID 1 OUTPUT INPUT OUTPUT INPUT ID 2 PWR ON IR ETHERNET INPUT OUTPUT OUTPUT ID 3 OUTPUT INPUT OUTPUT INPUT DVI-D_1 DVI-D_1 RS-232C OUTPUT INPUT RS-232C OUTPUT OUTPUT INPUT OUTPUT PWR OFF ID 4 HOR VER INPUT INPUT OUTPUT INPUT ID 6 DVI-D_1 RS-232C OUTPUT INPUT DVI-D_1 RS-232C DVI 1/2 DTV ID 5 DVI-D_1 IR DVI PC RS-232C INPUT DVI-D_1 RS-232C OUTPUT DVI-D_1 RS-232C 4) "USB Serial Port" is registered at the Control panel. The communication port number is shown as "COM23", The number of each USB port may be changed. OUTPUT INPUT RS-232C OUTPUT OUTPUT INPUT OUTPUT VIDEO S-VIDEO RS232 USB HDSDI DVIC1 HDMI DVIC2 IR ETHERNET RS232 USB ID 7 INPUT ID 8 INPUT ID 9 INPUT RS-232C New MFC DVI Signal Distributor (UXGA : UP TO 165MHz) USB MSCS control PC 18 | ORION CO., LTD. ORION CO., LTD. | 19 New Multi Function Controller Infinitely Expandable ON ID SETTING 05-6. Input Selection OFF 1 2 3 4 5 6 7 8 9 It receives Computer, HDMI, DTV, VIDEO, S-VIDEO, DVI, and HDSDI as input source, converts to DVI and sends to MPDP. 1) When the input source of the DVI converter is selected by MSCS program on the computer or the remote controller of New MFC, the corresponding LED is turned on. DVI 2 0 SET A B INFO 1.DVI ON DVI 1 OFF BROADCAST DVI CONVERTER INPUT ON PC DTV HDMI 2 3 VIDEO S-VIDEO HDSDI 7 8 4 5 DVIC1 DVIC2 OUTPUT RS-232C ID 2 INPUT DVI-D_1 PWR ON INPUT INPUT ID 3 INPUT DVI-D_1 RS-232C OUTPUT OUTPUT INPUT RS-232C OUTPUT OUTPUT INPUT ID 4 VER INPUT ID 5 INPUT DVI-D_1 IR DVI RS-232C DVI 1/2 DTV OUTPUT INPUT ID 6 OUTPUT INPUT DVI-D_1 DVI-D_1 RS-232C OUTPUT OUTPUT INPUT OUTPUT INPUT 1 OFF BROADCAST DVI CONVERTER INPUT ON PC DTV HDMI 2 3 VIDEO S-VIDEO HDSDI 7 8 4 5 DVIC1 DVIC2 OUTPUT 6 9 SET 1) Press PC button. OFF DVI 1 INFO AUTO FUNCTION DVI 2 0 PC MPDP A 2) PC LED is on. B PDP REMOTEINFO CONTROL OUTPUT 3.DTV INPUT DVI RS-232C OUTPUT DVI OUTPUT PWR OFF HOR PC OUTPUT DVI-D_1 RS-232C OUTPUT RS-232C OUTPUT ID SETTING INPUT INPUT 2) DVI LED is on. B DVI-D_1 RS-232C OUTPUT OUTPUT DVI 1 INFO AUTO FUNCTION DVI 2 PDP REMOTEINFO CONTROL ON DVI-D_1 9 1) Press DVI button. OFF A 2.PC DVI-D_1 6 0 DVI MPDP SET 2) Two outputs of the DVI converter can be selected and the corresponding LEDs are turned on. ID 1 DVI 1 All inputs are executed as full screen mode. ID SETTING New MFC is designed to control the input sources of DVI converter easily. INPUT OFF Input Selection This function is used for a DVI converter, sold separately. It indicates various inputs and outputs with a DVI converter. OUTPUT BROADCAST ON VIDEO S-VIDEO HDSDI DVIC1 HDMI DVIC2 ID 7 INPUT ID 8 INPUT ID 9 DVI CONVERTER INPUT VIDEO IR ETHERNET RS232 USB New MFC PC DTV S-VIDEO HDSDI DVIC1 DVIC2 OUTPUT RS-232C HDMI INFO AUTO FUNCTION DTV MPDP DVI Signal Distributor (UXGA : UP TO 165MHz) RS-232C DVI converter 1) Press DTV button. 2) DTV LED is on. PDP REMOTE CONTROL Video Signal RS-232C MSCS control PC 20 | ORION CO., LTD. ORION CO., LTD. | 21 ON OFF New Multi Function Controller ID SETTING 1 2 3 4 5 6 7 8 9 OFF DVI 1 DVI 2 0 SET Infinitely Expandable BROADCAST ON A B ON INFO 05-7. X x3 Y Configuration 1 2 4.VIDEO ON BROADCAST ON OFF DVI CONVERTER INPUT PC DTV HDMI VIDEO S-VIDEO HDSDI BROADCAST ON 4 5 6 7 8VIDEO9 1 2 3 ID SETTING DVIC1 DVIC2 OUTPUT 0 SET 4 5 6 7 8 9 (e.g. Horizontal 5 sets x Vertical 6 sets) OFF Horizontal configuration OFF INFO AUTO DVI 1 FUNCTION MPDP 1) Press VIDEO button. ID SETTING DVI OFF DVI 2 0 SET 2) VIDEO LED is on. DVI 1 A DVI 2 B 1) Press SET button. 2) Press Left and Right buttons sequentially to enter the horizontal configuration mode. INFO PDP REMOTE CONTROLB A OFF 5.S-VIDEO 1 DVI BROADCAST ON DVI CONVERTER INPUT ID SETTING 2 PC 3 DTV VIDEO 4 S-VIDEO 5 HDSDI 6 7 8 9 DVIC1 DVIC2 OUTPUT0 HDMI PC DTV VIDEO S-VIDEO HDSDI DVIC1 DVIC2 A INFO AUTO FUNCTION HOROUTPUT MPDP DVI 1 INFO AUTO DVI 2 FUNCTION 2) S-VIDEO LED is on. PDP REMOTE CONTROL ON OFF PDP INFO ON OFF REMOTE CONTROL 6.HDSDI ID SETTING 2 PC 3 DTV VIDEO 4 S-VIDEO 5 HDSDI 6 7 8 9 DVIC1 DVIC2 OUTPUT0 HDMI OFF DVI 1 INFO AUTO DVI 2 FUNCTION HDSDI MPDP SET 1) Press HDSDI button. ID SETTING 1 DVI 1 2 3 4 5 6 7 8 9 OFF DVI 1 DVI 2 0 SET 2) HDSDI LED is on. BROADCAST ON A A B 3) When the 2 LEDs at lower right corner of each 7-segment of Horizontal line in the New MFC are turned on, the horizontal configuration mode is started. VER B BROADCAST ON DVI CONVERTER INPUT HDMI 1) Press S-VIDEO button. OFF S-VIDEO MPDP SET DVI CONVERTER INPUT DVI INFO ON 4) U se the number buttons to set the numbers of MPDP sets in horizontal line. -e.g. If you want to set 5 for horizontal number, press "0" for the tens digit and "5" for the units digit. B HOR INFO PDP INFO REMOTE CONTROL 7.HDMI DVI DVI CONVERTER INPUT VIDEO PC DTV S-VIDEO HDSDI INFO AUTO FUNCTION HDMI MPDP PDP REMOTE CONTROL 22 | ORION CO., LTD. ON OFFINPUT DVI CONVERTER PC 2) HDMI LED is on. DTV S-VIDEO 4 5 7 8MPDP 9 2 3 6 DVIC1 DVIC2 OUTPUT OFF INFO AUTO FUNCTION DVI 1 0 SET HDMI BROADCAST HDSDI ON VIDEO 1 ID SETTING DVIC1 DVIC2 OUTPUT HDMI 1) Press HDMI button. DVI VER DVI 2 5) Press SET button to finish the horizontal configuration mode. PDP CONTROLB AREMOTE INFO DVI DVI CONVERTER INPUT VIDEO PC DTV S-VIDEO HDSDI HDMI ORION CO., LTD. | 23 New Multi Function Controller ON 05-8. BIC control Setting OFF ID SETTING 1 2 3 4 5 6 7 8 9 BROADCAST ON OFF Vertical configuration SET DVI 1 DVI 2 0 Infinitely Expandable A B 1) Press SET button. 2) Press Up and Down buttons sequentially to enter the vertical configuration mode. (Only applicable to OPM-4250, OPM-4250R) BIC (Burn-In Compensation) function is to reduce the visible burn-in effect on the screen by the communication with MPDP through New MFC. 1) There is BIC On/Off switch on the main board for BIC Control Setting. (See the white circle lower right corner of the following picture) INFO DVI CONVERTER INPUT DVI PC DTV VIDEO S-VIDEO HDSDI DVIC1 DVIC2 HDMI INFO AUTO FUNCTION HOROUTPUT MPDP 3) When the 2 LEDs at lower right corner of each 7-segment of Vertical line in the New MFC are turned on, the vertical configuration mode is started. 2) To turn on BIC, move the pin No.1 of the SW6 to On side. VER PDP REMOTE CONTROL ON ID SETTING 1 2 3 4 5 6 7 8 9 BROADCAST ON OFF DVI 1 DVI 2 0 SET A 4) U se the number buttons to set the numbers of MPDP sets in Vertical line. -e.g. If you want to set 6 for vertical number, press "0" for the tens digit and "6" for the units digit. KSD52S ON HOR BA1 2 3 BIC ON 4 5 BA1 2 3 4 5 BIC OFF 3) When the LED dot in the lower right side of 7-segment is turned on, BIC is started. B DVI KSD52S ON OFF INFO HOR ON OFFINPUT DVI CONVERTER PC DTV HDMI VIDEO S-VIDEO HDSDI BROADCAST ON 4 5 7 8MPDP 9 VER 1 2 3 ID SETTING 6 DVIC1 DVIC2 OUTPUT SET VER OFF INFO AUTO FUNCTION DVI 1 0 DVI 2 5) Press SET button to finish the vertical configuration mode. PDP CONTROLB AREMOTE INFO 24 | ORION LTD. DVI CO., CONVERTER INPUT DVI PC DTV VIDEO S-VIDEO HDSDI HDMI ORION CO., LTD. | 25 New Multi Function Controller Infinitely Expandable 06. Before calling for service 05-9. Baud-Rate Configuration 1) New MFC can be used as a communicational distributor for any devices with its various communicational speeds. Before calling for service, check the following and then contact the dealership where you purchased this product. 2) To configure the baud-rate, adjust the baud-rate switch(SW6), which is circled at the lower right corner of the following picture. 1. N ew MFC is not turned off even after MPDP power cable is disconnected. -N ew MFC and MPDP set work with the independent power supplies. When you need to turn on the MPDP again, please connect power cable and press "ON" button in the New MFC. - If you want to turn off New MFC, please disconnect the power cable of the New MFC. 2. New MFC does not work with no reason. Please disconnect and reconnect the adapter. - Please replace batteries of the remote controller. * SW6 is used for BIC on/off (Pin No.1) and baud-rated configuration (Pin No.3~5) commonly. 3) Baud-Rate Configuration 3pin Switch (SW6) - 3,4,5 4pin 9600bps On On - 19200bps Off On - Mode Daisy-chain In Daisy-chain Out 26 | ORION CO., LTD. 5pin 57600bps On Off 115200bps Off Off - 9600bps - - On 115200bps - - Off ORION CO., LTD. | 27 New Multi Function Controller Infinitely Expandable 07. Specification Product Name Remote Controller NEW MFC Adapter MEMO Specification Name MPDP REMOTE CONTROL Power 1.5V Battery(AAA) 2EA Size 55(W) x 190(L) x 25(H) mm Environmental Condition -10℃ ~ 40℃ Weight 130g Voltage +5~9V(DC), 1.25W (MAX) Power Consumption 250mA(Max, +5~9V) Size 58(W) x 216(L) x 46(H) mm Environmental Condition 0℃ ~ 40℃, 20 ~80% RH Weight 480g Size 35(W) x 80(L) x 86(H) mm Input 90~264V(47~63Hz) Output 5V, 2000mA Output Jack 2.1φ(Internal diameter):Vcc, 5.5φ(External diameter):GND Input/Output Specification NEW MFC Terminal Name RS-232C Control Input Terminal Specification D-Sub 9Pin (Female) Baud Rate : 115200 Ethernet RJ-45 TCP/IP USB Type B USB2.0 IR Max 15m, left/right 45°(standard : 3m) Key Button Control Mode Select (IR / Ethernet / RS-232C / USB) Control Output RS-232C (4ea) D-Sub 9Pin (Male) Baud Rate : 115200 Max ±15V MPDP ID Setting 7-Segment LED 1~99 MPDP Horizontal Number, Vertical Number - Minimum interval between button input: 0.6 second ※ Specification can be changed without prior notice to improve product quality. 28 | ORION CO., LTD. ORION CO., LTD. | 29 New Multi Function Controller MEMO 30 | ORION CO., LTD.