Download Infinitely Expandable MPDP

Transcript
A revolutionary MPDP
Infinitely Expandable MPDP
User’s Manual
A revolutionary MPDP
Infinitely Expandable MPDP
STAND UNIT / WALL UNIT
MAIN FRAME
ORION PDP CO.,LTD.
www.oriondisplay.net
• 2009.04.29
Address: 257-6, Gongdan-dong, Gumi-si, Gyeongsangbuk-do, Korea
Tel : +82-2-6678-8533, Fax: +82-2-6678-8599
Thank you for purchasing our MPDP.
Please read through this user's manual for safety before installing this product.
Contents
Accessory................................................................................ 2
OPTIONAL............................................................................... 2
STAND UNIT.......................................................................... 3
1. Safety Precaution............................................................... 4
2. Installing the stand (3*3)..................................................... 6
3. Installing the MPDP.......................................................... 16
4. Adjust the MPDP gap with the Adjuster........................... 19
5. Setting MPDP ID configuration and Connection (3X3)..... 20
WALL UNIT........................................................................... 21
1. Safety Precaution............................................................. 22
2. Checking the location for installation............................... 24
3. Fixing Anchor and Bolt..................................................... 25
4. Installing the Wall Bracket (3 X 3).................................... 26
5. Installing the MPDP . ....................................................... 37
6. Adjust the MPDP gap with the Adjuster........................... 41
SPECIFICATION ............................................................ 42
1
STAND UNIT
Infinitely Expandable
STAND UNIT
Infinitely Expandable
STAND UNIT
MAIN FRAME Accessories
¹¹ This manual describes the installation case for 3X3 sets.
¹¹ There are 4 different types of stand. Please select a stand type as you need.
STAND UNIT
Accessory
STAND BRACKET
STAND FOOT
BOLT M6*70 + NUT M6 4EA ADJUSTER M10*35 2EA
BOLT M6*12 4EA
MAIN FRAME
MAIN FRAME 1EA
FIX BRACKET 1EA
2608
Y-AXIS LINK 1EA
(Main frame link)
800
NX2
2570
2660
600
90
90
580
90
530
535.46
635.2
530
90
OPTIONAL
BOLT M8*15 4EA
NUT M8 4EA
2150
2240
2201.6
1630
1720
1560
SPANNER 1EA
505.85
TOOL SET 1SET
10mm
636.8
PEG 4EA
USER MANUAL 1EA
1470
1043.2
5mm 2.5mm
2721.6
1564.8
3150.64
2086.4
Round headed
BOLT M5*25L 4EA
800
850
NX3
NX4
900
NX5
※ In case of NX3, NX4, or NX5 set formations, there is no stand bracket for the top
line of main frames.
However, it is designed to firmly fasten the main frames of the top line to the main
frames of the next line.
6mm
Screen size (mm)
OPM-4240R / MIS-4210
MIS-4220R / MIS-4230R
ANCHOR BOLT 3/8" 2EA
STAND FOOT
STAND SUPPORT
2
BOLT M6*40 +
NUT M6 1EA
WALL BRACKET
OPM-4240 / MIS-4220
MIS-4230 / MIS-4230T
1X1
926.24 X 523.6
924.6 X 521.8
2X2
1852.48 X 1047.2
1849.2 X 1043.6
3X3
2778.72 X 1570.8
2773.8 X 1565.4
4X4
3704.96 X 2094.4
3698.4 X 2087.2
5X5
4631.2 X 2618.0
4623.0 X 2609.0
3
STAND UNIT
Infinitely Expandable
1. Safety Precaution
¹¹ Please read and understand this manual fully before installation.
¹¹ Please hand over this manual to customers after installation and ask to read
and keep this manual for future use.
※Please keep all the cautions and warnings for proper use of the product and prevent possible accident or hazard.
※You can find “CAUTION” and “WARNING” signs in this manual. Each sign has following meaning.
WARNING
If the user does not comply with this instruction, serious injuries or death
can be caused.
CAUTION
If the user does not comply with this instruction, minor injuries or product
damage can be caused.
Please install as described in this manual.
Installation of this product needs 3 or more
people.
Improper installation may cause serious injury or product
damage.
3 or more people need to work together to avoid personal injury
or product damage.
User's Manual
Use enclosed accessories.
Install on the even ground or floor.
Improper accessories may not withstand the weight of the
product. It may cause safety problems.
Product installed on uneven places such as inclined places or
stairways may fall and cause personal injury or product damage.
Do not use heaters or humidifiers at the place of
installation.
Heat or vapor may cause fire, electric shock or malfunction.
Do not install the product near to sprinkler, fire
detector, high-voltage cable, power source, or
places of vibration or impact.
Make sure to disconnect before installation.
Use working gloves when you install.
If you install the product while the power cord is still connected,
it may cause electric shock or fire.
Wear working gloves to avoid any injury.
WARNING
Installation must be done by the skilled persons
designated by sales agent or dealership.
Do not install at unstable locations that cannot
withstand product weight.
Installation work can be very dangerous for inexperienced
person.
In case of weak floor or ground, product may fall and cause
injuries.
It may cause serious injury or even death.
If you need to move or replace the product,
please contact with skilled persons designated
by sales agent or dealership
Do not hang on the product and avoid severe
impact to the product.
Product may fall and cause injuries.
If users move or install the product without proper skill and
experience, it may cause safety problem.
4
5
STAND UNIT
CAUTION
STAND UNIT
Infinitely Expandable
1
Connect the Foot Stand and Stand Support together.
2
Hook the main Frame to the lower part of the Stand.
yy When assembling, put the Foot Stand down to prevent it from falling.
yy Assemble the Main Frame from the lower to the upper part.
yy Attach the Stand Support to the upper and lower parts of the Foot Stand
yy Insert the M6*70 bolt to the Main Frame and Stand Hook.
yy After assembling, check if it would stand on its own.
yy If the M6*70 bolt was not inserted, the Main Frame would fall or be damaged.
STAND SUPPORT
M6*70
M8 NUT
Top
STAND FOOT
M8*12L
※It is more convenient to distinguish
top and bottom, if you put the main
frame as shown in the figure to use
the holes as indicators.
After inserting M8 NUT, apply
the M8*12 bolt with the enclosed
6mm wrench.
6
Bottom
7
STAND UNIT
2. Installing the stand (3*3)
STAND UNIT
ook the 2nd main Frame at the lower hook of the
H
center frame.
yy Insert the M6*70 bolt to the Main Frame and Stand Hook.
4
Assemble the two Main Frames.
yy Assemble the two Main Frames at the upper and lower parts with the M6*70 bolt using the
enclosed wrench and 5mm wrench.
yy If the M6*70 bolt was not inserted, the Main Frame would fall or be damaged.
M6*70
M6*70
Assemble the figure
using the enclosed
wrench and 5mm
wrench.
8
9
STAND UNIT
3
Infinitely Expandable
STAND UNIT
ook the 3rd Main Frame at the bottom row to the
H
Stand Hook.
6
Remove the M6*70 bolt.
yy Remove the M6*70 bolts inserted at the 1st and 2nd Main Frames.
yy Hook the Main Frame to the Stand Hook and assemble using a wrench and 5mm wrench.
yy Make sure that the Main Frame is securely assembled when working.
M6*70
M6*70
Assemble the figure using the
enclosed wrench and 5mm
wrench.
10
11
STAND UNIT
5
Infinitely Expandable
STAND UNIT
Assemble the Main Frame at the 2nd row.
8
Assemble the middle Main Frame at the 2nd row.
yy Hook the Main Frame at the 2nd row to the upper Stand Hook.
yy Hook the Main Frame at the 2nd row to the upper Hook.
yy Assemble the Main Frame at the 1st row and Main Frame at the 2nd Row with the M6*70
bolts.
M6*70
yy Repeat the work indicated in Step No. 7 to assemble the upper and lower Main Frames
and then assemble with the adjacent Main Frame with M6*70 bolts.
yy Repeat this process to assemble the Main Frame at the 3rd row.
M6*70
Assemble the figure using the
enclosed wrench and 5mm
wrench.
12
Assemble the figure using the
enclosed wrench and 5mm
wrench.
13
STAND UNIT
7
Infinitely Expandable
STAND UNIT
emove the supporting plate of both Main Frames at the
R
vertical axis.
yy Once the supporting plate of both Main Frames at the vertical axis is removed, the brackets
will move from side to side. Move the vertical axis at both sides to install the MPDP.
10
ix both rows at the vertical axis as "Y-Axis Link"
F
based on the right side.
yy Fix both rows at the vertical axis as "Y-Axis Link" to the right side of the Main Frame
bracket for the simultaneous movement of the vertical axis.
yy Do not remove the supporting plate of the supporting axis.

Fixed Cent
er Column

M6*12
Remove the screws of the supporting plate
with a 5mm wrench. Then, remove the plate
completely from the Main Frame.
Connect the Main Frame and Y-Axis Link
with M6*12 bolts using a 5mm wrench.
14
15
STAND UNIT
9
Infinitely Expandable
STAND UNIT
Infinitely Expandable
1
2
Attach the PEG and Guide Pin to the MPDP.
Install the MPDP from the lower part of the middle set.
yy Assemble the four PEGs at the back of MPDP.
yy Insert the PEGs in the PEG holes.
yy Install the Guide Pins where MPDP touches.
yy Put the set down slowly. The panels can be damaged by impact.
yy Install the MPDP from the bottom of both sides after completing the installation at the
lower middle part.
Guide Pin
There is a hole for
the installation of
the Guide Pin at the
upper part and the
sides.
7
5
2
4
1
PEG
M5*25
If you need to detach a MPDP set in the lower line, move
the set in the upper line to position "C". Remove guide
pins from the set in the lower line, move it to position "A"
and detach from the main frame.
Fasten 4 PEGs in the back
of MPDP with M5*25 bolts.
16
17
6
3
STAND UNIT
3. Installing the MPDP
STAND UNIT
Infinitely Expandable
3
ix the set by pushing towards the supporting plates
F
at the center of the vertical axis after completing the
installation of MPDP.
yy Install the Fix Bracket of both sets at the vertical axis by pushing towards the supporting
plates at the central area.

Fixed
Center
Column
The gap of the MPDP can be fixed using the Adjuster.
yy To fix the gap detected between the MPDP or when the MPDP is tilted after the
installation, use the Adjuster.
yy Install the Adjuster at the lowest part of the Main Frame using the 5mm wrench.

ADJUSTER
(M10*35)
5
4
5mm Wrench
3
2.5mm Wrench
10mm
0mm
0mm
2 1
Attach the fix bracket to the
main frame and fix with fixing
bolts next to MPDP handle. Use
2.5mm wrench.
MIS-4220
MIS-4230
MIS-4230T
OPM-4240
MIS-4220R
MIS-4230R
OPM-4240R
18
It is possible to lift or lower the Main
Frame using a 5mm wrench after the
Adjuster was installed at the lower
part of the Main Frame.
MIS-4210
19
STAND UNIT
4. Adjust the MPDP gap with the Adjuster.
STAND UNIT
Infinitely Expandable
onfigure MPDP ID and make connections for all the
C
necessary external devices and power.
WALL UNIT
¹¹ This manual describes the installation for 3X3 sets.
Apply following instruction according to the number of MPDP sets as you need.
yy Configure MPDP ID as shown in the following figure.
yy Make necessary connections such as speakers, VCR, DVD, PC and power, etc and finish
configuration.
yy Neatly arrange all the connection cables. If they are stretched out or disorganized, it may
cause personal injury or bad connection.
¹¹ For more information for ID configuration and connection, please refer to
MPDP user manual.
DVI-D
RS-232C
IN
OUT
ID 1
DVI-D
RS-232C
IN
IN
65
벽
DVI-D
OUT
OUT
ID 2
IN
OUT
ID 3
IN
RS-232C
ID 4
RS-232C
IN
DVI-D
IN
RS-232C
DVI-D
ID 6
IN
RS-232C
IN
IN
OUT
DVI-D
IN
OUT
OUT
OUT
ID 8
IN
OUT
ID 9
IN
40
ID 7
OUT
OUT
ID 5
OUT
DVI-D
IN
OUT
OUT
IN
OUT
RS-232C
40
OUT
DVI-D
IN
486.7
DVI-D
IN
486.7
MAIN FRAME
RS-232C
50
IN
OUT
OUT
190.35
WALL BRACKET
21 40
370.6
DVI Signal Distributor
(UXGA : UP TO 250MHz)
RS-232C control PC
DVI
20
21
WALL UNIT
RS-232C
50mm
40 55
5. Setting MPDP ID configuration and Connection (3X3)
WALL UNIT
Infinitely Expandable
1. Safety Precaution
CAUTION
※Please keep all the cautions and warnings for proper use of the product and prevent possible accident or hazard.
※You can find "CAUTION" and "WARNING" signs in this manual. Each sign has following meaning.
WARNING
If the user does not comply with this instruction, serious injuries or death
can be caused.
CAUTION
If the user does not comply with this instruction, minor injuries or product
damage can be caused.
WARNING
Installation must be done by the skilled persons
designated by sales agent or dealership.
Please install as described in this manual.
Installation of this product needs 6 or more
skilled people.
Improper installation may cause serious injury or product
damage.
6 or more people need to work together to avoid personal injury
or product damage.
User's Manual
Check the condition and type of wall before
installation. If all the condition fits, use enclosed
anchors and bolts.
Make sure to use the drill and bit of specified
diameter. Follow the instruction for the depth of
the hole, too.
Unauthorized anchors and bolts may not withstand the weight of
the product and may cause safety problems.
Unspecified way of drilling may cause unstable installation. It
may cause safety problems.
Do not use heaters or humidifiers at the place of
installation.
Do not install the product near to sprinkler, fire
detector, high-voltage cable, power source, or
places of vibration or impact.
Avoid weak or unstable locations.
MPDP sets may fall, if the location of installation cannot
withstand the weight of MPDP sets.
Installation work can be very dangerous for inexperienced
person.
It may cause personal injury or product damage.
It may cause serious injury or even death.
Heat or vapor may cause fire, electric shock or malfunction.
When you need to move or replace the
product after installation, contact with the
skilled persons designated by sales agent or
dealership.
Do not hang on the product or give any impact.
Product may fall and cause person injury.
Make sure to disconnect power cord before
installation.
Installation work can be very dangerous for inexperienced
person.
Use working gloves when you install.
Wear working gloves to avoid any injury.
If you install the product while the power cord is still connected,
it may cause electric shock or fire.
It may cause safety problems.
22
23
WALL UNIT
¹¹ Please read and understand this manual fully before installation.
¹¹ Please handover this manual to customers after installation and ask to read
and keep this manual for future use.
WALL UNIT
Infinitely Expandable
Check the type of wall to examine whether it can
withstand the weight of product.
3. Fixing Anchor and Bolt
¹¹ Make sure to use specified accessory.
¹¹ Check the positions and intervals.
If the hole positions are not accurate, the gap between MPDP sets can
be irregular.
yy Check the type and thickness of wall and the finish material.
yy Check the wall can withstand the weight of the product before installation.
yy You can use enclosed anchors and bolts, if the thickness of the finish material is 20mm or
less.
yy Never install the product to the wall of gypsum board.
Drill a hole with 8mm of diameter and
80mm~100mm of depth at the anchor spot
marked at the wall.
Drill
Check the installation space.
Clean the hole.
Insert the bolt into the hole.
Bolt
yy Select the location suitable for the product size and install to maintain the horizontal and
the vertical position.
yy Leave some space between the product and wall or other structures. (Minimum 15cm)
yy If the product is installed in a closed space, it may be a cause of fire or malfunction for its
internal heat.
Insert the sleeve along the bolt.
Sleeve
Attachment
Insert the attachment, and hit it to insert by the
hammer.
Hammer
WALL BRACKET
Washer
Nut
24
ix the WALL BRACKET and assemble the
F
washer and the nut.
Fasten the nut securely.
25
WALL UNIT
2. Checking the location for installation.
WALL UNIT
Infinitely Expandable
4. Installing the Wall Bracket (3 X 3)
2
Install the Wall Bracket.
yy Mark the location on the wall where the Bracket will be installed according to the number of
set and gap.
yy To install the Wall Bracket on the lowest part of the Main Frame, choose two areas at the upper
and lower parts for each set. Install the Wall Brackets facing each other at the bottom portion.
Hook the Main Frame at the lower part of the Wall Bracket.
yy Assemble the Main Frame starting from the lower to the upper part.
yy Insert M6*70 bolts to the Main Frame and the Wall Bracket.
yy If the M6*70 bolt was not inserted, the Main Frame would fall or be damaged.
yy Drill holes where the Wall Brackets will be installed using a drill and install the anchor bolts
(3/8”). Attach with Wall Brackets and nuts.
¹¹ Make sure that the horizontal and vertical lines are balanced when working.
924.5mm
924.5mm
M6*70
WALL UNIT
1
40mm
486.7mm
40mm
486.7mm
40mm
Top
370.6mm
40mm
※It is more convenient to distinguish top
and bottom, if you put the main frame
as shown in the figure to use the holes
as indicators.
anchor bolt anchor bolt
Attach the anchor bolts (3/8") and Wall
Brackets into the wall.
26
Install the Wall Brackets at the bottom
facing the upper parts.)
ANCHOR BOLT (3/8")
Bottom
27
WALL UNIT
Hook the 2nd Main Frame at the middle Wall Bracket.
yy Insert M6*70 bolts at the Main Frame and Wall Bracket.
yy If the M6*70 bolt was not inserted, the Main Frame would fall or be damaged.
4
Assemble the two Main Frames.
yy Assemble the two Main Frames at the upper and lower parts with M6*70 bolts using a
55mm Wrench.
WALL UNIT
3
Infinitely Expandable
M6*70
M6*70
Assemble the figure using the enclosed
wrench and 5mm wrench.
28
29
WALL UNIT
6
ook the 3rd Main Frame at the 3rd row from the
H
bottom to the Wall Bracket.
Remove the M6*70 bolts.
yy Remove the M6*70 bolts inserted at the 1st and 2nd Main Frames.
yy Hook the Main Frame to the Wall Bracket and assemble it with a wrench and 5mm
wrench.
yy Make sure that the Main Frame is securely assembled when working.
M6*70
WALL UNIT
5
Infinitely Expandable
M6*70
Assemble the figure using the
enclosed wrench and 5mm
wrench.
30
Assemble the figure using the
enclosed wrench and 5mm
wrench.
31
WALL UNIT
Assemble the Main Frame at the 2nd row.
8
Assemble the middle Main Frame at the 2nd row.
yy Hook the Main Frame at the 1st row to the upper Hook of the Stand.
yy Hook the Main Frame of the 2nd row to the Wall Bracket.
yy Assemble the Main Frame at the 1st row and Main Frame at the 2nd row with M6*70 bolts.
yy Repeat Step No. 7 to assemble the upper and lower Main Frames and then assemble the
adjacent Main Frame with M6*70 bolts.
yy Repeat this process to assemble the Main Frame at the 3rd row.
M6*70
M6*70
WALL UNIT
7
Infinitely Expandable
Assemble the figure using the enclosed
wrench and 5mm wrench.
32
Assemble the figure using the enclosed
wrench and 5mm wrench.
33
WALL UNIT
Assemble the upper part of the 3rd row with M6*40 bolts.
yy Assemble the Main Frame and Wall Bracket at the upper part and the lowest row with M6*40
bolts.
M6*40
10
emove the supporting plate of both Main Frames at
R
the vertical axis.
yy Once the supporting plate of both Main Frames at the vertical axis is removed, the
brackets move from side to side. Move the vertical axis at both sides to install the MPDP.
yy Do not remove the supporting plate of the supporting axis.

Fixed Center C
olumn

WALL UNIT
9
Infinitely Expandable
M6*40
Remove the screws of the supporting plate
with a 5mm wrench. Then, remove the
plate completely from the Main Frame.
Assemble the figure using the enclosed
wrench and 5mm wrench.
34
35
WALL UNIT
Infinitely Expandable
5. Installing the MPDP
11
ix both rows at the vertical axis as "Y-Axis Link"
F
based on the right side.
yy Fix both rows at the vertical axis as "Y-Axis Link" to the right side of the Main Frame bracket
for the simultaneous movement of the vertical axis.
1
Attach the PEG and Guide Pin to the MPDP.
yy Assemble the four PEGs at the back of MPDP.
yy Install the Guide Pins where MPDP touches.
Guide Pin
WALL UNIT
There is a hole for the
installation of the Guide
Pin at the upper part
and the sides.
M6*12
PEG
M5*25
Fasten 4 PEGs in the back of
MPDP with M5*25 bolts.
Connect the Main Frame and
"Y-Axis Link" with M6*12 bolts
using a 5mm wrench.
36
37
WALL UNIT
et MPDP ID and connect all the necessary external
S
devices and power.
3
Install the MPDP from the lower part of the middle set.
yy Insert the PEGs in the PEG holes.
yy Set ID, make necessary connections and power before hang the MPDP sets on the wall.
yy Put the set down slowly. The panels can be damaged by impact.
yy There is no room for such work after installation.
yy Install the MPDP from the bottom of both sides after completing the installation at the
lower middle part.
yy Set MPDP ID as shown in the following figure.
yy Make necessary connections such as speakers, VCR, DVD, PC and power, etc one by one.
yy It is easy to install the set after connecting the basic cables for the Wall Unit Type.
yy Neatly arrange all the connection cables. If they are stretched out or disorganized, it may cause
personal injury or bad connection
Process the connection
of various lines when
installing MPDP.
¹¹ For more information for ID setting and connection, please refer to MPDP user manual.
RS-232C
DVI-D
RS-232C
IN
OUT
ID 1
RS-232C
OUT
OUT
IN
DVI-D
ID 2
ID 4
RS-232C
RS-232C
IN
DVI-D
ID 7
DVI-D
OUT
OUT
ID 5
ID 3
DVI-D
OUT
IN
ID 8
DVI-D
OUT
OUT
ID 6
OUT
DVI-D
IN
IN
5
IN
RS-232C
OUT
OUT
7
IN
RS-232C
IN
OUT
OUT
IN
IN
RS-232C
DVI-D
OUT
OUT
IN
IN
OUT
RS-232C
IN
IN
IN
OUT
DVI-D
IN
ID 9
OUT
WALL UNIT
2
Infinitely Expandable
2
4
1
IN
6
3
DVI Signal Distributor
(UXGA : UP TO 250MHz)
If you need to detach a MPDP set in the lower line, move
the set in the upper line to position "C". Remove guide
pins from the set in the lower line, move it to position "A"
and detach from the main frame.
RS-232C control PC
38
DVI
39
WALL UNIT
Infinitely Expandable
6. Adjust the MPDP gap with the Adjuster.
ix the set by pushing towards the supporting plates
F
at the center of the vertical axis after completing the
installation of MPDP.
yy Install the Fix Bracket of both sets at the vertical axis by pushing towards the supporting
plates at the central area.

Fixed
Center
Column
The gap of the MPDP can be fixed using the Adjuster.
yy To fix the gap detected between the MPDP or when the MPDP is tilted after the
installation, use the Adjuster.
yy Install the Adjuster at the lowest part of the Main Frame using the 5mm wrench.
WALL UNIT
4

ADJUSTER
(M10*35)
5
4
5mm Wrench
3
2.5mm Wrench
10mm
0mm
0mm
2 1
Attach the fix bracket to
the main frame and fix with
fixing bolts next to MPDP
handle. Use 2.5mm wrench.
MIS-4220
MIS-4230
MIS-4230T
OPM-4240
MIS-4220R
MIS-4230R
OPM-4240R
40
It is possible to lift or lower the Main
Frame using a 5mm wrench after the
Adjuster was installed at the lower
part of the Main Frame.
MIS-4210
41
WALL UNIT
Infinitely Expandable
SPECIFICATION
MEMO
WALL UNIT
526.7
924.5mm[W] X 526.7mm[H] X 65mm[D]
336
External dimension
529
30
65
924.5
Weight
7kg (±0.5kg)