Download Load Cell Input Module User`s Manual

Transcript
CHAPTER 6 BUFFER MEMORY
1
(28)Calibration site gravitational acceleration (Un\G66, Un\G67)
This setting is used to set the gravitational acceleration at the calibration site.
The setting corrects weight errors caused by a difference in gravitational acceleration when the calibration site
differs from the installation site.
This setting is not required when the calibration site and installation site are the same.
The setting range is 97000 to 99999 (9.7000 to 9.9999G) (32-bit signed binary).
(a) Default
The default value is 98067 (9.8067G).
If the setting fails to satisfy the conditions, an error occurs.
For details on the conditions and the information on errors that occur, refer to the following.
• Minimum division (Un\G58) (
Page 138, Section 6.2 (23))
6
6.2 Setting Data Details
141