Download HLD7 User Manual - Contacta Global

Transcript
User guide
Contacta HLD7
T
Contents
Normal operation mode
2
Basic adjustment mode
3
Engineers mode
5
Rear panel connections 13
Connections
No serviceable parts inside. The warranty for this product will be void if the HLD7 housing is opened.
14
2
Contacta | HLD7
Normal operation mode
Shows MIC level
MIC
Shows LINE level
LINE
CLIP
ACTIVE
PHTM
Active on power on
Indication only- buttons have no
effect, except unlock combination.
Back to contents
Shows DRIVE level
CLIP
ACTIVE
LOW SIG
DRIVE
PERIMETER
MASTER
SLAVE
STATUS
POWER
3
Contacta | HLD7
Basic Adjustment mode
MIC
CLIP
ACTIVE
PHTM
To enter Adjustment mode press
both MIC + and - simultaneously.
Back to contents
LINE
CLIP
ACTIVE
LOW SIG
DRIVE
PERIMETER
MASTER
SLAVE
STATUS
POWER
In Adjustment mode the
STATUS LED will flash.
4
Contacta | HLD7
Basic Adjustment mode
MIC
CLIP
ACTIVE
PHTM
LINE
CLIP
ACTIVE
LOW SIG
DRIVE
PERIMETER
MASTER
SLAVE
STATUS
POWER
While in Adjustment mode
While in Adjustment mode
While in Adjustment mode
Pressing the MIC + or - will
adjust the MIC input gain,
adjustments are in 1dB steps.
Pressing the LINE + or - will
adjust the LINE input gain,
adjustments are in 1dB steps.
Pressing the Drive + or - will
adjust the Drive output by
1dB steps.
LEDs show the MIC’s level
after fader.
LEDs show the LINE level
after fader. If input is low the
LOW SIG LED will illuminate.
LEDs show the DRIVE level in
approx 0.5A increments.
Signal Level for inputs should be set to have peak signal
level occasionally illuminating first amber LED.
Back to contents
5
Contacta | HLD7
Engineers’ mode
MIC
CLIP
ACTIVE
PHTM
LINE
CLIP
ACTIVE
LOW SIG
While in Adjustment mode
Press both Line + and simultaneously to enter the
Engineers’ mode.
Back to contents
DRIVE
PERIMETER
MASTER
SLAVE
STATUS
POWER
6
Contacta | HLD7
Engineers’ mode (PAGE 1)
Driver Operation Selection
MIC
LINE
CLIP
ACTIVE
PHTM
CLIP
ACTIVE
LOW SIG
DRIVE
PERIMETER
MASTER
SLAVE
STATUS
POWER
While in Engineers’ mode
While in Engineers’ mode
While in Engineers’ mode
There are 6 PAGES of settings,
each PAGE is identified by a flashing
MIC LED, PAGE 1 is LED 1, Page 2
is LED 2 etc.
PAGE1 Pressing the LINE + or buttons selects driver operation,
Perimeter, MASTER or SLAVE.
When you are ready to move
onto the next PAGE press the
DRIVE + button.
Always select the driver operation mode before
installing the driver in its rack mount bracket.
Back to contents
To exit Engineers’ mode press
the DRIVE - button.
7
Contacta | HLD7
Slave mode
MIC
CLIP
ACTIVE
PHTM
LINE
CLIP
ACTIVE
LOW SIG
DRIVE
PERIMETER
MASTER
SLAVE
STATUS
POWER
To adjust drive when in slave
mode press DRIVE + and together. Status LED will flash.
Press DRIVE + to increase level.
Press DRIVE - to reduce level.
Press DRIVE + and - together
when adjustment complete.
Back to contents
8
Contacta | HLD7
Engineers’ mode (PAGE 2)
High Frequency compensation
MIC
CLIP
ACTIVE
PHTM
LINE
CLIP
ACTIVE
LOW SIG
DRIVE
PERIMETER
MASTER
SLAVE
STATUS
POWER
While in Engineers’ mode
While in Engineers’ mode
While in Engineers’ mode
PAGE 2 is identified by
LED 2 flashing.
PAGE 2 settings are for the High
Frequency compensation,
adjustments can be made by
pressing the LINE + or - buttons.
When you are ready to move
onto the next PAGE press the
DRIVE + button.
There are 6dB of HF compensation
adjustment possible.
This adjustment is required to
compensate for loss of high
frequencies due to the presence
of metal within the proximity of
the loop.
Back to contents
To exit Engineers’ mode press
the DRIVE - button.
9
Contacta | HLD7
Engineers’ mode (PAGE 3)
Microphone Phantom power selection
MIC
CLIP
ACTIVE
PHTM
LINE
CLIP
ACTIVE
LOW SIG
DRIVE
PERIMETER
MASTER
SLAVE
STATUS
POWER
While in Engineers’ mode
While in Engineers’ mode
While in Engineers’ mode
PAGE 3 is identified by
LED 3 flashing.
PAGE 3 settings are for the
Microphone Phantom power
selection.
When you are ready to move
onto the next PAGE press the
DRIVE + button.
Pressing the LINE + button turns the
phantom power on, pressing the LINE
- button turns phantom power off.
To exit Engineers’ mode press
the DRIVE - button.
Back to contents
10
Contacta | HLD7
Engineers’ mode (PAGE 4)
Firmware Revision indication
MIC
CLIP
ACTIVE
PHTM
LINE
CLIP
ACTIVE
LOW SIG
DRIVE
PERIMETER
MASTER
SLAVE
STATUS
POWER
While in Engineers’ mode
While in Engineers’ mode
While in Engineers’ mode
PAGE 4 is identified by
LED 4 flashing.
PAGE 4 Firmware revision indication.
When you are ready to move
onto the next PAGE press the
DRIVE + button.
Back to contents
THIS MODE IS DISPLAY ONLY: NO
SETUP CAN BE CHANGED.
To exit Engineers’ mode press
the DRIVE - button.
11
Contacta | HLD7
Engineers’ mode (PAGE 5)
Diagnostics indication
MIC
CLIP
ACTIVE
PHTM
While in Engineers’ mode
PAGE 5 is identified by
LED 5 flashing.
LINE
CLIP
ACTIVE
LOW SIG
PAGE 5 is for indication only.
DRIVE
PERIMETER
MASTER
SLAVE
STATUS
POWER
While in Engineers’ mode
When you are ready to move
onto the next PAGE press the
DRIVE + button.
To exit Engineers’ mode press
the DRIVE - button.
Back to contents
12
Contacta | HLD7
Engineers’ mode (PAGE 6)
Restore to factory settings
MIC
CLIP
ACTIVE
PHTM
LINE
CLIP
ACTIVE
LOW SIG
DRIVE
PERIMETER
MASTER
SLAVE
STATUS
POWER
While in Engineers’ mode
While in Engineers’ mode
While in Engineers’ mode
PAGE 6 is identified by
LED 6 flashing.
PAGE 6 is for restoring settings.
To go back to PAGE 1 press the
DRIVE + button.
Back to contents
Press the LINE + and LINE button Simultaneously.
To exit Engineers’ mode press
the DRIVE - button.
13
Contacta | HLD7
Rear panel connections
PHTM
PWR
PUSH
PUSH
12-
HLD7
contactaglobal.com
Phantom power
indication for
microphone
LINE
POWER
ONLY USE
PS-60 PSU
24v 4.17A
LOOP
STATUS
MICROPHONE
1+
2+
FEATURE
EXPANSION
LOOP
Input 1 (Microphone)
Expansion
Status
Loop output
Balanced XLR with switchable
12VDC phantom power
Contacta
interconnect input or
output determined by
the driver operation
mode selected,
Perimeter: Output
Master: Phased Output
Slave mode: Input
External LEDs
or relays.
Loop connection
4-pole speakON
connector.
or
¼” TRS jack for electret microphone
with 12VDC power via 680Ω load.
Input 2 (Line)
Balanced XLR
or
¼” TRS jack to ohmically isolated input.
Back to contents
2 x constant
current drive @ 20mA,
22V max.
Feature
External monitor
& control.
Contacta
communications
processor interface.
Loop drive current
4A RMS compliance
current @ 1Khz sine
wave.
Loop drive voltage
15V RMS compliance
voltage.
Power supply
input
14
Loop
connector|
Contacta
4 pole SpeakON
1–
2–
HLD7
20mm
8mm
1+
2+
Connections
LOOP
Loop connector
4 pole SpeakON
1–
2–
Mic & Line
XLR connector
1+
2+
LOOP
1: Screen / Shield
2: + (Signal Hot)
3: - (Signal Cold)
2
20mm
8mm
Mic
Unbalanced Stereo TRS Jack
Tip
Ring
Sleeve
Audio connections
1
SOURCE
+ (Signal)
GND
Mic &
3 Line
XLR connector
1: Screen / Shield
2: + (Signal Hot)
3: - (Signal Cold)
2
Mic
Unbalanced Mono
Jack
StereoTS
TRS
Jack
TipTip
Ring
Sleeve
Sleeve
1
Line
Unbalanced Mono TS Jack
SOURCE
+ (Signal)
SOURCE
+ (Signal)
Mic
Unbalanced Mono TS Jack
Tip
Sleeve
SOURCE
+ (Signal)
GND
SOURCE
+ (Signal) hot
– (Signal) cold
GND
GND
3
Tip
Sleeve
This connection will pass through an
Isolating Transformer inside the HLD7.
Line
Unbalanced Mono TS Jack
Tip
Sleeve
SOURCE
+ (Signal) hot
– (Signal) cold
This connection will pass through an
Isolating Transformer inside the HLD7.
Back to contents
contactaglobal.com