Download CEMDPS User Guide

Transcript
CEMDPS User Guide
What is CEMDPS?
Correction: The words “Relative accuracy test audit for initial cert.” should read “Relative
accuracy test for initial cert.” and “Annual relative accuracy test audit” should read “Annual
relative accuracy test” for opacity CEMSs. Non-opacity CEMSs should be handled as stated in
the record type.
RT 848: Certification Report Analyzer Test Completion Date
Inconsistency: Start Col 73 requires the type of testing to be identified for opacity and nonopacity analyzers. Tests for opacity and non-opacity analyzers should be identified differently.
Correction: The words “Linearity testing” should read “Calibration error testing”. The words
“Cycle time testing” should read “Response time test” and “7-day calibration error testing” should
read “zero and calibration drift-24 hour check” for opacity analyzers. Non-opacity analyzers
should be handled as stated in the record type.
RT 860: Certification Report Linearity Data
Inconsistency: The record type requires linearity test data for opacity and non-opacity
analyzers. Tests for opacity and non-opacity analyzers should be identified differently.
Correction: Calibration error test results should be entered for opacity analyzers instead of
linearity test results. Non-opacity analyzers should be handled as stated in the record type.
RT 868: Certification Report 7-Day Calibration Error Data
Please note that this information should only be submitted for non-opacity analyzer 7-day
calibration error test runs. Opacity zero and calibration drift-24 hour test results will need to be
submitted as an attachment to the test report submittal. Please contact the Chief of the CEM
Section for instructions.
RT 872: Certification Report Cycle Time Data
Please note that cycle time test data should be submitted for non-opacity analyzers and response
time test data should be submitted for opacity analyzers. Start Col 83 will accommodate 1-5
periods for use in reporting test information.
RT 888: Emission Data Report Linearity Results
Please note that linearity results should be submitted for non-opacity analyzers and calibration
error test results should be submitted for opacity analyzers.
PA Department of Environmental Protection
7