Download CEMDPS User Guide
Transcript
CEMDPS User Guide What is CEMDPS? Correction: The words “Relative accuracy test audit for initial cert.” should read “Relative accuracy test for initial cert.” and “Annual relative accuracy test audit” should read “Annual relative accuracy test” for opacity CEMSs. Non-opacity CEMSs should be handled as stated in the record type. RT 848: Certification Report Analyzer Test Completion Date Inconsistency: Start Col 73 requires the type of testing to be identified for opacity and nonopacity analyzers. Tests for opacity and non-opacity analyzers should be identified differently. Correction: The words “Linearity testing” should read “Calibration error testing”. The words “Cycle time testing” should read “Response time test” and “7-day calibration error testing” should read “zero and calibration drift-24 hour check” for opacity analyzers. Non-opacity analyzers should be handled as stated in the record type. RT 860: Certification Report Linearity Data Inconsistency: The record type requires linearity test data for opacity and non-opacity analyzers. Tests for opacity and non-opacity analyzers should be identified differently. Correction: Calibration error test results should be entered for opacity analyzers instead of linearity test results. Non-opacity analyzers should be handled as stated in the record type. RT 868: Certification Report 7-Day Calibration Error Data Please note that this information should only be submitted for non-opacity analyzer 7-day calibration error test runs. Opacity zero and calibration drift-24 hour test results will need to be submitted as an attachment to the test report submittal. Please contact the Chief of the CEM Section for instructions. RT 872: Certification Report Cycle Time Data Please note that cycle time test data should be submitted for non-opacity analyzers and response time test data should be submitted for opacity analyzers. Start Col 83 will accommodate 1-5 periods for use in reporting test information. RT 888: Emission Data Report Linearity Results Please note that linearity results should be submitted for non-opacity analyzers and calibration error test results should be submitted for opacity analyzers. PA Department of Environmental Protection 7