Download Manual BlueSense Module - Go
Transcript
BlueSense Module 2 Technical Data and Connection Diagrams 2.1 Technical Data Article-Nr. 486 M00- Inputs: • 1 or 2 analogue inputs (1 Control parameter or 2 Control parameters) The particular configuration is on the shipping note, the serial number of the BlueSense Module is written on the type plate at the right hand side of the housing. • 2 digital inputs (static), potential-free contacts, switching current approx. 6 mA • 2 pulse inputs selectable to PNP/NPN (optional: static), switching current approx. 6 mA, measurement range 0.05 Hz – 1000 Hz G O S y s te m e le k tro n ik G m b H Ty p e : M e s s u m f o r m e r A r t . N r. : 4 8 6 M 0 0 A n s c h lu s s w e rte : 230V SN: 1234 1 5 /1 8 G O S y s t e m e le k t r o n ik G m b H 2 4 1 0 8 K ie l Te l.: 0 4 3 1 /5 8 0 8 0 0 F a x 5 8 0 8 0 11 E m a il: b lu e b o x @ g o - s y s .d e In t e r n e t : w w w .g o -s y s .d e Outputs: • • 2 relays with a low-voltage (only) switching capacity of 24 V / 0.5 A 2 relays with a switching capacity of 230 VAC / 2 A or 24 VDC / 6 A Interfaces: • CAN-bus connector for connection to the BlueBox System, 50 Kbit/s Voltage feed: ∗ • 12 VDC (9 V – 18 V), received power max. 7 W or • 24 VDC (18 V – 36 V), received power max. 7 W or • 230 VAC (90 V – 260 V), received power max. 7 W Housing: Polycarbonate, 235 mm x 185 mm x 119 mm; protection code IP65; Weight: approx. 1.2 kg Ambient temperature: -10 °C to +45 °C ∗ The type of your BlueSense Module is documented on the label on the inside of the cover lid of the cable connections. GO Systemelektronik GmbH Faluner Weg 1 24109 Kiel www.go-sys.de Germany Tel.: +49 431 58080-0 [email protected] Fax: -58080-11 Page 5 / 14