TriggerRepeat Purpose Specify number of additional times trigger executes Description You can configure a trigger to occur once (one-shot acquisition) or multiple times. If TriggerRepeat is set to its default value of zero, then the trigger executes once. If TriggerRepeat is set to a positive integer value, then the trigger executes once, and is repeated the specified number of times. For example, if the value is set to 2, you will get a total of 3 triggers. If TriggerRepeat is set to inf then the trigger executes continuously until a stop function is issued or an error occurs. You can quickly evaluate how many triggers have executed by examining the TriggersExecuted property or by invoking the display summary for the device object. The display summary is invoked by typing the device object name at the MATLAB command line. Characteristics Usage AI, Common Access Read/write Data type Double Read-only when running Yes Values The default value is zero. See Also Functions disp, stop Properties TriggersExecuted, TriggerType 14-108