Download T-8000. - ITC Audio
Transcript
3. REAR PANEL LAYOUT EXTENSION LINK OUTPUT + 3 - 2 0V 1 0.775V/600 + 3 - 2 0V 1 OUTPUT 0.775V/600 + LINK IN dB HF +10 dB -10 LF +10 dB -10 LINK OUT dB HF +10 dB -10 LF +10 dB -10 3 - 2 1 OUTPUT 0.775V/600 LF +10 dB -10 dB HF +10 dB -10 LF +10 dB -10 PAGE REMOTE WALL CONTROL dB HF +10 dB -10 2 1 LF +10 dB -10 + 3 - 2 0V 1 OUTPUT 0.775V/600 LF +10 dB -10 PAGE 3 - 2 1 0.775V/600 + GAIN dB HF +10 dB -10 LF +10 dB -10 GAIN dB HF +10 dB -10 LF +10 dB -10 - - ZONE 6 + dB - ZONE 7 + dB - PAGE REMOTE WALL CONTROL DISABLE ENABLE DISABLE ENABLE ZONE 8 + dB - PAGE REMOTE WALL CONTROL REMOTE WALL CONTROL DISABLE ENABLE OUTPUT + 0V + dB +10 dB -10 - REMOTE WALL CONTROL DISABLE ENABLE 0.775V/600 HF ZONE 5 + dB - PAGE OUTPUT GAIN - ZONE 4 + dB - REMOTE WALL CONTROL DISABLE ENABLE 3 - + GAIN - + dB - + 0V + GAIN ZONE 3 EMC IN GROUND EVAC ALERT + GAIN GAIN - dB + - dB + - dB + - dB + L L 195mV-2V/47K L G + 3 - dB 1 2 0V LINE 6 + - MIC:5mV LINE:350mV G + 3 - dB 1 2 0V 300mV-1.1V/10K MIC:5mV LINE:350mV G + REMOTE SOURCE 6 GAIN 3 - dB 1 2 0V 300mV-1.1V/10K LINE 7 + - REMOTE SOURCE 5 GAIN REMOTE WALL CONTROL DISABLE ENABLE + DISABLE ENABLE REMOTE SOURCE 7 GAIN 3 - dB 1 2 0V 300mV-1.1V/10K dB 1 300mV-1.1V/10K + 0V REMOTE SOURCE 8 GAIN 3 2 dB 1 300mV-1.1V/10K LINE 8 MIC:5mV LINE:350mV + - G LINE MIC PHANTOM R GAIN 195mV-2V/47K 2 300mV-1.1V/10K LINE 5 GAIN L 3 0V REMOTE SOURCE 4 GAIN LINE MIC PHANTOM R + - dB 1 300mV-1.1V/10K LINE MIC PHANTOM 2 0V LINE 4 LINE 3 R 3 - dB 1 LINE MIC PHANTOM 2 300mV-1.1V/10K LINE 2 R + - COMMON 3 + + - dB + LINE 1 - + REMOTE SOURCE 3 GAIN - dB REMOTE SOURCE 2 GAIN + + 0V - REMOTE SOURCE 1 GAIN - EMC INPUT + TONE OUTPUT - BATT SUPPLY 2A 24V + 0V + SLAVE3 +10 dB -10 - DISABLE ENABLE 0.775V/600 - SLAVE2 dB HF PAGE OUTPUT + SLAVE1 1 - MASTER 2 + 1 3 - + GAIN ZONE 2 + dB - PAGE + 0V - 4 0.775V/600 775mV/10K 1 2 ON OUTPUT + 3 FIRE ALARM CONTACT CLOSURE 2 3 4 5 6 7 8 G 1 - REMOTE WALL CONTROL 230V 115V INPUT VOLTAGE SELECTOR 2 + GAIN ZONE 1 + dB - PAGE 3 - + GAIN - ~115V/230V 50-60Hz + 0V MICROPHONE 1 PAGING MIC1 PAGING MIC2 GAIN GAIN - dB + - dB + MIC:5mV LINE:350mV GAIN LF HF dB -8 dB +8 -8 dB +8 5mV-300mV/680 1 Dip Switches 9 LF Bass 2 EVAC / Fire System Interface 10 Output 17 Line Inputs 18 Paging Console Inputs 3 Tone Output 11 Gain 19 Paging MIC Gain 4 EMC Input 12 HF 20 MIC 1 Input 5 Extension Link 13 Enable/Disable Switch 21 MIC 1 Gain 6 Remote Source 14 Remote Source Gain 22 MIC 1 Bass 7 Remote Control Input 15 Fire Alarm 23 MIC 1 H 8 Page 16 Line Gain 1. Dip Switches 4 MASTER SLAVE1 SLAVE2 SLAVE3 1 2 ON 3 4 3 4 Master Slave 1 MASTER SLAVE1 SLAVE2 SLAVE3 For the avoidance of doubt, if a Matrix unit is confi -gured as a slave,the slave Matrix Inputs 1 - 8,MIC1 and remote paging consoles inputs will be disabled. However, the optional wall plates can be used to operate these additional zones. 1 2 ON MASTER SLAVE1 SLAVE2 SLAVE3 If you are expanding the system, only line in puts 1-8 ,MIC 1 and 2 x Remote Paging Consoles of the Master Matrix are enabled .All Slave Matrix units connected to the Master will use the Master Matrix inputs. MASTER SLAVE1 SLAVE2 SLAVE3 Dip switch settings are as follows for configuring the T-8000 as a Master or Slave: Dip switches set the Matrix system address.If the system is to be expanded, each ITC unit must be defined as Master, Slave1,2or3. 1 2 ON 1 2 ON 3 4 Slave 2 3 4 Slave 3