If "Machine Option Management" is set, but no valid configuration is set yet, no
other diagnostics are sent. Diagnostics are only sent after a valid configuration is
set.
If "Machine Option Management" is set and individual lines are disabled using
Index 10, it may occur that the diagnostic message issued for missing modules
may contain incorrect slot numbers.
5.1.2
Index 12 BusControl
Byte 0 BusControl:
7
6
5
4
3
2
1
0
0  1 Disable US/UA on all lines
1  0 US/UA enabled on all lines
and software reset
Unassigned
Fig, 21 Bit assignment of Byte 0
The PLC can reset the bus nodes using the BusControl request. This may reset a possibly present UA
short-circuit or other fault after its rectification and without switching the power supply of the Cube67+
BN-PNIO on or off manually.