E_In2
Auto2
The counter is automatically erased
after reaching this value. The write of -19999...99999
the value 0 switches the function off.
CLr2
functions:
On – Control inputs steers the
work of the auxiliary counter.
Off – Control inputs do not
influence the auxiliary counter
work.
Permit for external
start/stop, erasing
Erase the counter contents. The
choice of the option Y causes the
rewrite of the value Auto2 to the
counter and the transition of the
function in the state n.
nO – Do not erase,
YeS – Erase the counter,
AUtO2 – rewrite value of
AUtO2 to aux counter
Table 3
Ind
Parameter
symbol
22
Description
Range of changes
IndCp
Number of points of the individual
characteristic. For a value lower than 2,
the individual characteristic is switched
off. The number of segments is the
number of points reduced of one.
In CountH and HoUr modes, the individual characteristic is not taken into
consideration.
1...21
Xn
Point value for which we will expect Yn
(n-point number)
-19999...99999
Yn
Expected value for Xn.
-19999...99999