4.1. Lead-out of Signals
Signals led out on the meter connectors are presented on the fig. 4. All
input signals are separated between them and separated from other
circuits. Circuits of successive groups of signals are separated between them.
Fig. 4. Description of Signals on Connection Strips
Clamps
1-2
3-4
5-6
7-8
9-10
Description
Clamps
Description
W3- Main input. Counting of pulses 11-12 alarm output 1, relay
downwards.
13-14 alarm output 2, relay
W2 - Additional input. Auxiliary
15-16 24 V external transducer supply
counter.
output
W1- Main input. Counting of pulses 17-18 supply
20-21-22 RS-485 output
upwards.
RST- Reset input (reset) of the main 23-24 analog output 1, voltage
25-26 analog output 1, current
counter or/and auxiliary counter.
The function is available after swit- 27-28-29 alarm output 3, relay
30-31-32 alarm output 4, relay
ching in the meter menu on.
34-35 OC – open collector output of
S/S – start/stop of counting. The
npn type– signaling of the range
function is available after switching
overflow.
in the meter menu on.