Download OPERATING MANUAL
Transcript
Sound Level Meter 1 2 Trigger Events Choose from the following settings: Off No event triggering on level above Events are triggered at noise levels above the preset value 2 for the start duration 13 . on level below Events are triggered at noise levels below the preset value 2 for the start duration 13 . on ext. keypress Events are triggered by external keypress. 3 on level above Stop level = Start level 2 - Hysteresis on level below Stop level = Start level 2 + Hysteresis 14 14 Stop Duration 12 The event stop is triggered when the noise level is lower (or higher) than the preset value and continues for the preset duration. Hysteresis 14 Set the hysteresis to an appropriate value to prevent rapid switching on and off as the level drifts around the Start level. Start [dB] Set the level at which the triggered event is started. Start Duration 13 The event start is triggered when the noise level is higher (or lower ) than the preset value and continues for the preset duration. Stop [dB] Set the level at which the triggered event is stopped. 4 Level Selection Define the level type to be monitored. 57