Display units
Measurement
Wf
Forward RF output power
Wreal
Real RF output power
VBias
DC bias voltage
xxxx # Arcs
Displayed only if arc detection is enabled. The number of arcs
detected outside the specified limits. This counter is reset each
time RF is turned on. Arcs within the RF on or setpoint delay
time are not counted.
If you specified a cable attenuation value, see “Using the Cable Attenuation Feature”
on page 5-54 for a description of the values displayed on the front panel.
If the front panel displays Error E xxx, you have an error condition. See the
Troubleshooting section of the user manual.
REMOTE CONTROL OPERATION
By default, when you switch on the Cesar generator it is in front panel control mode.
You can also operate the generator in remote control mode via either the host port or
the User Port.
• Front panel control
This is the default control mode.
• Host port remote control
To use the host port commands, the unit must be in host port remote control
mode. Once activated, the unit will remain in host port remote control mode
until deactivated by command 14 or until the generator is switched off.
• User Port remote control
You can activate User Port remote control mode via either the front panel or
via host port command 14. Once activated, the unit will remain in User Port
remote control mode even if the generator is switched off and on. You can
deactivate User Port remote control via either the front panel or host port
command 14.
Additionally, you can specify overrides to the remote control modes (see “Setting and
Disabling Remote Control Override” on page 5-36).
5‑24
Installation, Setup, and Operation