Best Practices Indirectly Detected and Undetected Faults This refers to faults that go undetected by equipment alarm monitors or faults indicated by a module that is not the source of the fault. Clearance requires a process of elimination based on experience, knowledge of the equipment, and sound troubleshooting logic. For example, a noisy receiver local oscillator may cause a high BER condition and possibly a demux alarm. The first approach may be to replace the demux module, but it would not be until the RF module was replaced that the problem would be resolved. Similarly, incompatible optical signal levels into or out of a link may cause a dribbling BER, which on first analysis may indicate a fault within the radio. Isolation of this type of problem is assisted by careful observation of alarm indications and historical data. Typical Fault Scenarios For fault descriptions, probably causes, and recommended actions for a range of typical path related faults, refer to Appendix D. Diagnostic Tools This section describes the following diagnostic tools and processes: • Loopbacks • Fade Margin • Tx Power Measurement • Feeder Return Loss • Interference Measurement • Bench Testing 280-200019-001 Rev 005a June 2007 9-7