Download Technical Description FORMIGA P 100 Technical Description

Transcript
Technical Description FORMIGA P 100
-
Required floor space
see installation requirements
-
Compressed air consumption
-
Standard pressure
7 bar
-
Minimum pressure
6 bar
-
Maximum pressure
10 bar
-
Compressed air temperature
approx. 20 m³/h at 7 bar
max. 10 °C above ambient air temperature
Quality of compressed air in accordance with DIN ISO 8573:
-
Solids
-
Water content
-
Oil content
1.2
Class 1 (particle size ≤ 0.1 µm,
Particle density ≤ 0.1mg/m³)
Class 4 (compressed air saturation point ≤ 3 °C)
Class 1 (oil concentration ≤ 0.01 mg/m³)
Exposure unit
-
CO2 laser
-
Wave length of laser
-
Laser radiation power at time of delivery
(nominal power)
-
Minimum radiation power within
warranty period (12 months)
30 W
10.6 µm
min. 30 W
28 W
Laser beam scanning (Scanner)
High-speed rotating mirror scanning system uses precision galvanometer scanners with
temperature compensation, integrated servo- and interface electronics, digital data transfer
from the systems control computer and digital signal processing.
-
Exposed area
200 x 250 mm
-
Scanning speed
up to 5 m/s
-
Positioning accuracy of laser beam
± 0.05 mm