Download Technical Description FORMIGA P 100 Technical Description

Transcript
Technical Description FORMIGA P 100
Laser beam with divergence optics and flat-field lenses
-
Diameter of focused beam
-
Divergence ratio
-
Focal length of flat-field lenses
-
Aperture of the scanners
1.3
< 0.5 mm
3.5:1
440 mm
20 mm
Recoating unit
Radial recoating system for the generation of a new powder layer and fed by a powder supply
container. An overflow container is not required for FORMIGA P 100 as no excess material
occurs.
Minimum layer thickness
0.05 mm
-
Layer thickness variation
0.01 mm
Supply container (2 units)
-
1.4
Capacity of container
about 15 litres each
Heating
The building process heaters are operated separately for the upper process chamber and the
lower unloading chamber. Both heater loops separately are controlled and observed.
-
1.5
Area heating
2.4 kW
Nitrogen generator NG-3H (integrated protective gas generator with cooling
system)
The protective nitrogen generator separates compressed air into nitrogen and oxygen. Nitrogen
is used for cooling the optics and as a protective gas for the process. Oxygen is allowed to flow
into the ambient in order to prevent high nitrogen concentrations from becoming hazardous for
the operating personal.
-
Total air consumption (Vn)
-
Purity of N2
ca. 10 m³/h
> 99 %
EOS GmbH - Electro Optical Systems
Robert-Stirling-Ring 1
D-82152 Krailling / München
FP / 04/16/2007
TD_P100_en.doc
3 / 17
Telefon:
Telefax:
Internet:
+49 (0)89 / 893 36-0
+49 (0)89 / 893 36-285
www.eos.info