Download 6 - Electrocomponents
Transcript
PR5651 Rev11 595 Engineers Ref Guide.qxd 21/02/2006 13:27 Page 88 GardTec 595 Engineer’s Reference Guide NovActive Description & Programming NovActive utilises a four core bus to the NovActive sounders that are fitted to the system. This allows each individual Bell to to programmed and also gives access to unique Diagnostic Features that allow the individual NovActive sounders to be diagnosed from either the control panel or via GardTec Remote PC Software. GardTec Remote may be used from either a remote location via a Modem or on-site via a GardTec Modem Patch Lead. To program the NovActive sounder(s) please follow the instructions below. Wiring of the NovActive should be carried out in conjunction with the instructions supplied with the unit. 1) Enter into Engineer Mode To do this follow Steps 1 to 4 on page 9 With the display showing:- Program . . . . Zones ? 2) Press No three times. The display will show:- 3) Press Yes. The display will show:- 4) Press Yes. The display will show:- NovActive = Off 5) Press No twice. The display will show:- NovActive > On 6) Press Yes. The display will show:- Page 88 ___ Program . . . . ___ Bells / Sounders ? Program Bell Type ? Select NovActive 1-8