Download T632 GB2 ML Rev.0315 X7.cdr
Transcript
USER MANUAL Video door entry system 2 wires installation GB2 Nexa Modular Cod. 50121878 T632 GB2 EN REV.0315 2 VIDEO DOOR ENTRY SYSTEM GB2 NEXA MODULAR - BUILDING INTRODUCTION First of all we would like to thank and congratulate you for the purchase of this product. The commitment to reach the satisfaction of our customers is stated through the ISO-9001 certification and for the manufacturing of products like this one. Its advanced technology and exacting quality control will do that customers and users enjoy with the legion of features this system offers. To obtain the maximum profit of these features and a properly wired installation, we kindly recommend you to expend a few minutes of your time to read this manual. INDEX Introduction....................................................................................................................................................................2 Index..............................................................................................................................................................................2 Starting recommendations............................................................................................................................................. 2 Safety precautions......................................................................................................................................................... 3 Characteristics...............................................................................................................................................................3 System operation........................................................................................................................................................... 3 Door panel description (Nexa Modular)............................................................................................................................. Door panel description.................................................................................................................................................4 Sound module description (EL632-GB2)..................................................................................................................... 5 Push buttons module description (EL610D).................................................................................................................6 Embedding box positioning......................................................................................................................................... 7 Preparing the cables entry........................................................................................................................................... 7 Place the embedding box............................................................................................................................................ 8 Assembly electronic modules...................................................................................................................................... 8 Hold the frame............................................................................................................................................................. 9 Plug the push buttons with the sort connection cable.................................................................................................... 9 Plug the push buttons with the connection cable (RAP-610D)..................................................................................... 10 Push buttons coding................................................................................................................................................... 10 Double push button module coding.............................................................................................................................11 Single push button module coding......................................................................................................................... 12-13 Configuration dip-switch.............................................................................................................................................14 Configuration jumper.................................................................................................................................................. 14 Description of the leds lighting (low light conditions).................................................................................................... 14 Description of the visual indications on the door panel.................................................................................................14 Description of the vocal synthesis (audible indications from the door panel)................................................................ 15 Adjusting the door panel communication volume........................................................................................................ 15 Adjusting the vocal synthesis volume..........................................................................................................................15 Selecting the vocal synthesis language...................................................................................................................... 16 Configuring the contact type for Relay 1 and Relay 2 (door release)............................................................................ 16 Close the frame.......................................................................................................................................................... 16 Place the nameplate labels.........................................................................................................................................16 Door panel and double door panel assembly..........................................................................................................17-18 Close the door panel...................................................................................................................................................19 Power supply installation (FA-GB2)............................................................................................................................... 20 Lock release Installation................................................................................................................................................20 Installation diagrams................................................................................................................................................21-26 Notes............................................................................................................................................................................ 27 . STARTING RECOMMENDATIONS - Do not use excessive force when tightening the power supply connector screws. - Install or modify the equipment, without the power connected. - The installation and handling of these equipments must be performed by authorised personnel. - The entire installation must be at least 40cm. away from any other installation. - Before to connect the system, check the connections between door panel, power supply, distributors, memory module MM-GB2, camera unit D-CAM-GB2, interface GSM-GB2, monitors and telephones. 2 - Use RAP-2150 (2x1mm ) Golmar cable. - Do always follow the enclosed information. VIDEO DOOR ENTRY SYSTEM GB2 NEXA MODULAR - BUILDING SAFETY PRECAUTIONS - Install or modify the equipment, without the power connected. - The installation and handling of these equipments must be performed by authorised personnel. - The entire installation must be at least 40 cm. away from any other installation. - With power supply: wDo not use excessive force when tightening the connector screws. wInstall the power supply in a dry and protected place without risk of drip or water projections. wAvoid to place it near to heating sources, in dusty locations or smoky enviroments. wDo not block ventilation holes of the unit so that air can circulate freely. wTo avoid damage, the power supply has to be firmly fixed. wTo avoid an electrical shock, neither remove the protection cover nor handle the connected wire in the terminals. CHARACTERISTICS - Video door entry system with simplified installation (2 wire bus without polarity). - Up to 4 access door panel (necessary DP-GB2 distributor for more than 1 door panel access) per installation. - Up to 20 monitors and apartments with Vesta monitor per installation. - Up to 15 monitors and apartments with Thera monitor per installation. - Up to 4 monitors per apartment. - Acoustic call acknowledgment signal. - Visual indications on the door panel for people with impaired hearing, indicating (call progress, communication, door open and system busy). - Audible indications from the door panel for people with impaired vision, indicating (call is in progress, resident unavailable, door is open, communication is finished and system is busy). - Door opening timed at 1 or 5 seconds. - 2 outputs for lock release (separate activation). - Output “Relay 1": a.c or d.c lock release operated by relay. - Output “Relay 2" a.c or d.c lock release operated by relay. - Input for external door release push button (Relay 1). - Input for external door release push button (Relay 2). 2 - Maximum distance between power supply and furthest door panel: 80m with a wire section of 1mm. 2 - Maximum distance between power supply and furthest distributor: 80m with a wire section of 1mm. 2 - Maximum distance distributor and monitor: 40m with a wire section of 1mm. SYSTEM OPERATION - To make a call the visitor should press the push button corresponding to the desired apartment; an acoustic tone will be heard confirming the call is in progress once the push button has been pressed and the led will turn on. If the vocal synthesis is enabled the message “call is in progress” will be heard confirming the call is in progress. At this moment the apartment´s monitor(s) receives the call. During the call the visitor can correct his call by pressing a push button corresponding to a different apartment, in which case the original call is cancelled. - In systems with several accesses doors, the other(s) door panel(s) will be automatically disconnected: if a visitor tries to call from other door panel an acoustic tone will be heard and the led will turn on. If the vocal synthesis is enabled the message “system is busy, try later” will be heard confirming the system is busy - The call lasts for 40 seconds. Without alerting the visitor, their image is displayed on master monitor to receive the call. To view the picture on a slave monitor this function must first be activated in the monitor. If the call is not answered within 40 seconds, the led will turn off and the system will be freed. - To establish communication, press the push button of any monitor to the apartment; door panel led will turn on. If the vocal synthesis is enabled the message “you can speak now” will be heard confirming the communication is activated. - Communication will last for one and a half minutes or until the button is pressed again. Once the communication has finished, the leds and will turn off and the system will be freed. If the vocal synthesis is enebled, the message “communication is finished” will be heard in the door panel confirming the communication has finished. - To open the door, press the door release push button during call or communication progresses: with one press, the door release operates for 5 seconds, the led will also turn on for 5 seconds. If the vocal synthesis is enabled, the message “door is open” will be heard in the door panel. - For the operation and configuration monitor, see the corresponding monitor manual. 3 VIDEO DOOR ENTRY SYSTEM GB2 NEXA MODULAR - BUILDING DOOR PANEL DESCRIPTION (NEXA MODULAR) Door panel description: General detail of parts, for assembly the door panel. Embedding boxes Frame modules Electronic modules Aluminium door panel Door panel description. Screws of fixation of header (x4) Screws of fixation of embedding box (x2) Closing heads: 60xx Lateral rod * Door panel UNE rod Grille module: N1000/AL N1110/AL 1P. N2220/AL 2P. Nexa spacer module Push buttons module: 3xxx Lateral rod (x2) * Door panel UNE rod: It allows to join 2 door panels, (see page 18). Sound module EL632/GB2 , on video systems with color camera. Push buttons electronic module EL610D , for 5 single push buttons or 10 double push buttons. Short connection cable, it is supplied with EL610D module (16 cm length). For the connection of the push buttons between the sound module and the push buttons module EL610D and between push buttons modules EL610D. Connection cable RAP-610D (27 cm length). For the connection of the push buttons between the sound module and the push buttons module EL610D and between push buttons modules EL610D. This cable is necessary when the distance between modules to connecting is greater due to the distribution of these modules in the door panel(s). 4 VIDEO DOOR ENTRY SYSTEM GB2 NEXA MODULAR - BUILDING SOUND MODULE DESCRIPTION (EL632/GB2) Sound module description (EL632/GB2): Front side. Color camera. Leds (visual indications for people with impaired hearing). Leds (environment low luminosity). Speaker. Microphone. Sound module push buttons (x2). Back side. Internal use. Push buttons connector. 123456 ON Internal use. Configuration dip switch. No modify (internal use). Push button number. Installation terminals (GB2 Bus). Installation terminals: _ +, : Positive, ground (12Vdc output for Golmar 12Vdc lock release). C1 : "C" contact for lock release (Relay 1). NA1 : "N.O" contact for lock release (Relay 1). _ AP ,AP+ .: Input for external door release push button (Relay 1). NA2 : “N.O” for lock release (Relay 2). C2 : “C” contact for lock release (Relay 2). AP+,AP _ : Input for external door release push button (Relay 2). P1 : Input for external call push button (push button 1). P2 : Input for external call push button (push button 2). BUS .: Communication Bus (without polarity). BUS .: Communication Bus (without polarity). Note: See installation diagrams for wiring (pages 21 to 26). 5 VIDEO DOOR ENTRY SYSTEM GB2 NEXA MODULAR - BUILDING PUSH BUTTONS MODULE DESCRIPTION (EL610D) Push buttons module description (EL610D): Front side. Push buttons module (x10). Back side. Input / output push buttons connector (x3). Configuration dip switch (Push buttons call code). Push button number. 6 VIDEO DOOR ENTRY SYSTEM GB2 NEXA MODULAR - BUILDING DOOR PANEL INSTALLATION Embedding box positioning: 1850 1450 1650 The upper part of the door panel should be placed at 1,65m. height roughly. The hole dimensions will depend on the type of door panel. Modules Model 1 NCEV90CS 2 NCEV90C 3 CEV90 W H D 99 135,5 40 99 238 56 99 mm. 328 mm. 56 mm. The door has been designed to be placed under most of the environmental conditions. However it’s recommended to take additional cautions like (covered places, rainproof covers, ...). To obtain a good quality picture on video door entry systems, avoid direct incidence from light sources. Preparing the cables entry: Break the bottom flange to pass the cables through. In case of door panels with more than one embedding box, break the side flanges and attach the embedding boxes using UC junctions. 7 VIDEO DOOR ENTRY SYSTEM GB2 NEXA MODULAR - BUILDING 8 DOOR PANEL INSTALLATION Place the embedding box: Pass the wiring through the hole made in the bottom part of the embedding box. Level and flush the embedding box. Once the embedding box is placed, remove the protective labels from the attaching door panel holes. Assembly electronic modules: Insert the sound module in the top part of the module frame. Align the tabs on the sound module in their respective housings of the module frame and then exercise a light pressure until correct placement. If there is push buttons module repeat the above process, locating under the sound module, as shown in the drawing. Frame Frame Sound module EL632/GB2 Push buttons module EL610D VIDEO DOOR ENTRY SYSTEM GB2 NEXA MODULAR - BUILDING DOOR PANEL INSTALLATION Hold the frame on the embedding box: Insert the hinge that it is supplied with the product in the embedding box, as shown in the drawing. To hold the frame on the embedding box, insert the hinge in the housings arranged for this purpose in the frame, as shown in the drawing. The frame can now be folded horizontally facilitating the connection and adjustments in the sound module and push buttons electronic module. ON 123456 Plug the push buttons with the short connection cable: Insert the short connection cable that it is supplied with the product EL610D, in the push buttons connector of the sound module and the other end of the connection cable in the connector placed in the top part of the push buttons EL610D module, as shown in the drawing. Between push buttons modules EL610D of the same embedding box, insert the short connection cable of the low connector of the first push buttons module to the top connector of the second push buttons module, as shown in the drawing. Between push buttons modules EL610D of different embeddingt boxes, insert the short connection cable in the low connector of the last module EL610D of the first embedding box and the other end of the connection cable in the middle connector of the last push buttons module EL610D placed in the low part of the second embedding box, as shown in the drawing. 9 10 VIDEO DOOR ENTRY SYSTEM GB2 NEXA MODULAR - BUILDING DOOR PANEL INSTALLATION Plug the push buttons with the connection cable RAP-610D: Use the connection cable RAP-610D, for the connection of the push buttons between the sound module and the push buttons module EL610D and between push buttons modules EL610D, when the distance between modules to connecting is greater due to the composition of the door panels. Configuration of the push-buttons code: The push buttons module EL610D must be configured, to assign a call code to the push buttons. Make this configuration with the dip switch placed in the back side of the module. Depending on the setting selected, the push buttons are assigned to a specific call code. To configure the monitor address call code, it will be necessary to known the call code of each push button, as shown in the table below. ( ) * Push buttons module EL-610D Double push button module coding Dip switch Push buttons code Dip1 Dip2 Dip3 Dip4 Dip5 Dip6 Dip7 Dip8 P1 P2 P3 P4 P5 P6 P7 P8 P9 P10 (1) 1 On Off Off Off Off Off Off On 11 2 3 4 5 6 7 8 9 10 (*) 2 Off On Off Off Off Off Off On 21 12 13 14 15 16 17 18 19 20 Module configuration option 3 Off Off On Off Off Off Off On 31 22 23 24 25 26 27 28 29 30 Single push button module coding Dip1 Dip2 Dip3 Dip4 Dip5 Dip6 Dip7 Dip8 P1 P2 P3 P4 P5 (1) 5 (*) 1 On Off Off Off Off Off Off On 1 2 3 4 2 Off On Off Off Off Off Off On 6 7 8 9 10 3 Off Off On Off Off Off Off On 11 12 13 14 15 4 Off Off Off On Off Off Off On 16 17 18 19 20 5 Off Off Off Off On Off Off On 21 22 23 24 25 6 Off Off Off Off Off On Off On 26 27 28 29 30 _ _ _ _ 7 Off Off Off Off Off Off On On 31 (1)P1- P10: Push button 1 to push button 10. Note: Sound module, factory set the code "0" in P1 and "1" in P2. Important: Select a different configuration option for each module EL610D. ( ) Factory default. * 11 VIDEO DOOR ENTRY SYSTEM GB2 NEXA MODULAR - BUILDING DOOR PANEL INSTALLATION Double push button module coding: ON P2 123456 EL632/GB2 P1 + 12Vdc Code 1 P2 2 1 _ C1 NA1 AP- AP+ NA2 C2 AP+ AP- P1 P2 BUSBUS Relé 1 Relé 2 Code 0 Code 1 EL610D Code 10 Code 9 9 10 Code 10 Code 8 Code 7 7 8 Code 8 Code 6 Code 5 5 6 Code 6 Code 4 Code 3 3 4 Code 4 Code 2 Code 11 1 2 Code 2 Code 20 Code 19 9 10 Code 20 Code 18 Code 17 7 8 Code 18 Code 16 Code 15 5 6 Code 16 Code 14 Code 13 3 4 Code 14 Code 12 Code 21 1 2 Code 12 Code 30 Code 29 9 10 Code 30 Code 28 Code 27 7 8 Code 28 Code 26 Code 25 5 6 Code 26 Code 24 Code 23 3 4 Code 24 Code 22 Code 31 1 2 Code 22 ON 1234 5678 ON 1234 5678 ON 1234 5678 12 VIDEO DOOR ENTRY SYSTEM GB2 NEXA MODULAR - BUILDING DOOR PANEL INSTALLATION Single push button module coding: ON P2 123456 EL632/GB2 P1 + 12Vdc - - - - - P2 2 1 _ C1 NA1 AP- AP+ NA2 C2 AP+ AP- P1 P2 BUSBUS Relé 1 Relé 2 Code 0 EL610D - - - - - Code 5 9 10 - - - - - Code 4 7 8 - - - - - Code 3 5 6 - - - - - Code 2 3 - - - - - Code 1 1 2 - - - - - Code 10 9 10 - - - - - Code 9 7 8 - - - - - Code 8 5 6 - - - - - Code 7 3 - - - - - Code 6 1 2 - - - - - Code 15 9 10 - - - - - Code 14 7 8 - - - - - Code 13 5 6 - - - - - Code 12 3 - - - - - Code 11 1 ON 1234 5678 ON 1234 5678 ON 1234 5678 4 4 4 2 Continue VIDEO DOOR ENTRY SYSTEM GB2 NEXA MODULAR - BUILDING DOOR PANEL INSTALLATION Coming from previous page. EL610D - - - - - Code 20 9 10 - - - - - Code 19 7 8 - - - - - Code 18 5 6 - - - - - Code 17 3 - - - - - Code 16 1 2 - - - - - Code 25 9 10 - - - - - Code 24 7 8 - - - - - Code 23 5 6 - - - - - Code 22 3 - - - - - Code 21 1 2 - - - - - Code 30 9 10 - - - - - Code 29 7 8 - - - - - Code 28 5 6 - - - - - Code 27 3 - - - - - Code 26 1 2 - - - - - - - - - - 9 10 - - - - - - - - - - 7 8 - - - - - - - - - - 5 6 - - - - - - - - - - 3 - - - - - Code 31 1 ON 1234 5678 ON 1234 5678 ON 1234 5678 ON 1234 5678 4 4 4 4 2 13 14 VIDEO DOOR ENTRY SYSTEM GB2 NEXA MODULAR - BUILDING DOOR PANEL INSTALLATION Configuration dip switch of the sound module (EL632/GB2): ( ) 123456 * ON The configuration dip switch is located on the left side of the rear part of the module. ( ) * ON 123456 ( ) * 123456 ( ) * 1 + _ C1 Set to OFF for door panels with double push buttons and set to ON for door panels with single push buttons. ON Set to OFF for door panels to be used in villas and set to ON for use in buildings. 123456 * ON 123456 ( ) ON 123456 Set to ON to congure the door release time to 5 seconds. Set to OFF to congure the door release time to 1 second Set to ON to congure: (see page 16) The vocal synthesis language (using the sound module's P1 push button). The door release Relay 1 and Relay 2 to N.O or N.C (using the sound module's P2 push button). Set to OFF when conguring is complete. ( ) Factory default. Description of the configuration jumper: ( ) * ON * 123456 ( ) * ON Door Panel Address: Dip switches: 1 and 2 OFF (address 1), 1 ON and 2 OFF (address 2), 1 OFF and 2 ON (address 3), 1 and 2 ON (address 4). Important: Do not change the factory default position of the configuration jumper. 1 ( ) Factory default. * + Description of the door panel LED lights (low light conditions): The door panel LED lights will turn on during a call if there is low light, allowing the person who called to be seen on the apartment's monitor. Description of the visual indications on the door panel: Visual indications on the door panel for people with impaired hearing: - While calling: The led will turn on during the call and while in communication. - During communication: The led - During door release: The led - End of communication: The leds will turn on during the communication process. will turn on during door release. and will turn off. - Calling at one door panel while another door panel is communicating (with more than one door panel): The led will turn on for 3 seconds. - While calling and the monitor is in (do not disturb) mode: The led - While calling (apartment with no monitor or telephone): The led will turn on for 4 seconds. will turn on for 4 seconds. _ C1 VIDEO DOOR ENTRY SYSTEM GB2 NEXA MODULAR - BUILDING DOOR PANEL INSTALLATION Description of the vocal synthesis (audible indications from the door panel): Audible indications from the door panel for people with impaired vision. If the vocal synthesis in the sound module is activated (see pages 14 and 16 to congure), a voice with the following messages can be heard from the door panel: - While calling: “Call is in progress”. - Start communication: “You can speak now”. - During door release: “Door is open”. - End of communication: “Communication is nished”. - Calling at one door panel while another door panel is communicating (with more than one door panel): “System is busy, try later”. - While calling and the monitor is in "Do not disturb" mode: “Resident unavailable”. - While calling (apartment with no monitor or telephone): “Resident unavailable”. Adjusting the door panel communication volume: If after starting the system the door panel audio volume seems inadequate, follow these steps: - Call an apartment. - The call is received in the apartment. Establish communication by pressing the push button on the monitor. - Next, press the same push button used to call the apartment for 3 seconds until a series of conrmation tones are heard and the door panel communication led’s starts to blink. - Each press on the same call push button will increase the door panel volume and the led's blink speed. . There are 5 volume settings and the led’s blink speed will vary for each. Slow to fast blink - low to high volume. After reaching “setting 5”, that is maximum blink speed and volume, the next setting is “setting 1”, that is minimum blink speed and volume (carousel mode). - To save the volume setting keep the same push button used to call the apartment pressed until a series of conrmation tones are heard and the door panel communication LED turns off. Adjusting the vocal synthesis volume: If after starting the system the vocal synthesis volume of the door panel seems inadequate, follow these steps: - Within 10 seconds of connecting power to the door panel press any call push button on the door panel. - Keep the call push button pressed until the synthesis volume is heard and the door panel communication led ...starts to blink. - Each press on the same call push button will increase the synthesis volume and the LED's blink speed. There are 5 volume settings and the LED's blink speed will vary for each. Slow to fast blink - low to high volume. After reaching “setting 5”, that is maximum blink speed and volume, the next setting is “setting 1”, that is minimum blink speed and synthesis volume (carousel mode). - To save the volume setting keep the same push button used to call the apartment pressed until a series of conrmation tones are heard and the door panel communication LED turns off. 15 16 VIDEO DOOR ENTRY SYSTEM GB2 NEXA MODULAR - BUILDING DOOR PANEL INSTALLATION Selecting the vocal synthesis language: To activate the voice synthesis of the door panel, follow these steps: - Set dip 6 of the sound module's conguration dip switch to ON (see page 14), a conrmation tone will be heard. - The desired language can be set using the sound module's P1 push button. - Each press will change the language. Continue doing this until the desired language is heard. - Once nished set dip 6 on the conguration dip switch to OFF. A conrmation tone will be heard P1 Configuring the contact type for Relay 1 and Relay 2 (door release): To change the contact type for door release activation of Relay 1 and Relay 2 of the door panel, follow these steps: - Set dip 6 of the sound module's conguration dip switch to ON (see page 14), a conrmation tone will be heard. - Use the sound module's P2 push button to select the desired contact type (N.O factory default or N.C). - Each press will change the contact type. A long conrmation tone will be heard if the selected contact is N.O or two short tones if the selected contact is N.C. Stop pressing P2 when the desired tone is heard. - Once nished set dip 6 on the conguration dip switch to OFF. A conrmation tone will be heard. P2 Description: Normally open: N.O Normally closed: N.C Important: The selected contact type will apply to both Relay 1 and Relay 2. Close the frame: Once finished the works of wiring, configuration and adjustments, fix the frame in the embedding box with the supplied screws. Important: Before closing the door panel(s), make a test call to any apartment to ensure that it works correctly. Place the nameplate labels: Open the label holder. Place the label and close. 17 VIDEO DOOR ENTRY SYSTEM GB2 NEXA MODULAR - BUILDING DOOR PANEL INSTALLATION Door panel assembly: Insert a header in the lateral rods (at the bottom part) and fix it with the supplied screws (step 1 ), then insert the module (step 2 ). If the door panel is more than one module insert first the lower module, see picture A . Place the spacer module (step 3 ) and insert the next module (step 4 ) see picture B . Repeat this procedure in case of door panels with one more module (the maximum number of modules placed vertically is three). To finish insert the second header (step 5 ) in the lateral rods (at the top part) and fix it with the supplied screws, see picture C . A Lateral rod B C 2,9 x 13 DIN-7981 4 Lateral rod 3 2 1 2,9 x 13 DIN-7981 5 18 VIDEO DOOR ENTRY SYSTEM GB2 NEXA MODULAR - BUILDING DOOR PANEL INSTALLATION Double door panel assembly: Assembly the door panel A (step 1 ), as it is described in page 17 "door panel assembly”. Bear in mind that the rod that will join the door panel A and the door panel B have to be of the type door panel UNE rod, see picture below. Insert a header between door panel UNE rod and the second lateral rod (at the bottom part) and fix it with the supplied screws (step 2 ), then insert the module (step 3 ). If the door panel is more than one module insert first the lower module. Place the spacer module (step 4 ) and insert the next module (step 5 ). Repeat this procedure in case of door panels with one more module (the maximum number of modules placed vertically is three). To finish insert the last header between door panel UNE rod and the second lateral rod (at the top part) and fix it with the supplied screws (step 6 ). 2,9 x 13 DIN-7981 Door panel UNE rod A A B 6 5 4 3 1 Lateral rod 2 Door panel UNE rod Lateral rod 2,9 x 13 DIN-7981 Lateral rod IMPORTANT: Once finished the adjustments, stick the adhesive gasket (that it is supplied with the set of closing heads N60XX CMPL) in the door panel UNE rod. VIDEO DOOR ENTRY SYSTEM GB2 NEXA MODULAR - BUILDING DOOR PANEL INSTALLATION Close the door panel: Fix the door panel in the embedding box with the supplied screws. Finish the door panel assembly by placing the closing heads, put the head on one side and then make a slight pressure on the other end, to its correct placement. Door panel: Double door panel: 19 20 VIDEO DOOR ENTRY SYSTEM GB2 NEXA MODULAR - BUILDING POWER SUPPLY INSTALLATION Installing the FA-GB2 power supply: Install the power supply in a dry and protected place without risk of drip or water projections. To avoid an electrical shock, neither remove the primary protection cover nor handle the connected wire in the terminals. The installation and handling of these equipments must be performed by authorised personnel and without the power connected. To avoid damage, the power supply has to be firmly fixed. It's recommended to protect the power supply by using a thermo-magnetic circuit breaker. Din rail. Mount the din rail to the wall with wallplugs and screws that are supplied with power supply. Next, place the power supply simply pressing it. Din rail. Din rail. The power supply can be installed on a DIN 46277. To disassemble the power supply from the DIN rail, use a plain screwdriver to lever the flange as shown on the picture. The FA-GB2 model uses 8 units over DIN rail. . DIN 46277 DIN rail latch release. IMPORTANT: The maximum number of units that can be connected to a FA-GB2 power supply is 20 monitors “VESTA GB2" or 15 monitors “THERA GB2". Replace the protection cover once the input terminals have been wired. LOCK RELEASE INSTALLATION Installing the lock release: 3,5 x 25 DIN-7972 If the lock release will be installed in a metal door, use a Ø3,5mm. drill and tap the hole. In case of wood door, use a Ø3mm. drill. M4x8 DIN-963 IMPORTANT: The lock release must be of (Golmar) 12Vd.c or a.c. See page 26 (a.c lock release) and pages 21 to 26 (d.c lock release). 21 VIDEO DOOR ENTRY SYSTEM GB2 NEXA MODULAR - BUILDING INSTALLATION DIAGRAMS Video installation with 20 VESTA monitors, 5 DP-GB2 distributors and Golmar 12Vd.c lock release: CODE 3 ** CODE 1 CODE 16 ** CODE 2 ** CODE 0 End of line ON B C BUS BUS A VESTA BUS VESTA DP-GB2 D BUS BUS ** ** * VESTA B C BUS BUS A VESTA BUS VESTA Distances and Sections: DP-GB2 VESTA C Main 100~240Vac VESTA C N N L N.A CN2 B Cable A 2 FA-GB2 Twisted 2x0.75mm 2 Twisted 2x1mm B C Internal rele D 60m 60m 30m 10m 80m 80m 40m 15m A Access door panel D SW1 * ON Configuring the end of line in the last distributor. Switch to On. 1 + ** Configuring the end of line in the last monitor. Dip 6 to On. _ 12Vdc 2 3 4 5 6 C1 NA1 AP- AP+ NA2 C2 AP+ AP- P1 P2 BUSBUS Relé 1 Relé 2 (1) (1) Lock release max. 12 Vdc/270mA. AP (1) Important: For connection of 12Va.c lock release or a 2nd lock release, (see page 26). CN1 FA-GB2 BUS (M) BUS (PL) DP-GB2 D BUS BUS End of line OFF BUS BUS VESTA BUS CODE 17 CODE 18 BUS ** VESTA ** BUS CODE 19 BUS VESTA ** 22 VIDEO DOOR ENTRY SYSTEM GB2 NEXA MODULAR - BUILDING INSTALLATION DIAGRAMS Video installation with 20 VESTA monitors, 10 D2L-GB2 distributors and Golmar 12Vd.c lock release: VESTA VESTA * End of line CODE 18 (1) D1 BUS VESTA End of line CODE 2 (1) D1 BUS VESTA End of line (1) OFF D2 BUS D1 BUS Distances and Sections: D2L-GB2 VESTA C VESTA Main 100~240Vac C N N L N.A B CN2 Cable A 2 FA-GB2 Twisted 2x0.75mm 2 Twisted 2x1mm B C Internal rele D 60m 60m 30m 10m 80m 80m 40m 15m A Access door panel D (1) Do not change the factory default position of the configuration jumper. SW1 ON * ** Take off jumper of all the distributors except in the last one. 1 + Configuring the end of line in the last monitor. Dip 6 to On. _ 12Vdc 2 3 4 5 6 C1 NA1 AP- AP+ NA2 C2 AP+ AP- P1 P2 BUSBUS Relé 1 Relé 2 (2) (2) Lock release max. 12 Vdc/270mA. AP (2) Important: For connection of 12Va.c lock release or a 2nd lock release, (see page 26). CN1 FA-GB2 BUS (M) BUS (PL) BUS CODE 0 BUS BUS ** BUS CODE 1 BUS D2 BUS VESTA ** BUS OFF D2L-GB2 BUS ** BUS CODE 3 BUS D2 BUS VESTA ** BUS ON D2L-GB2 BUS ** D2L-GB2 CODE 19 BUS ** 23 VIDEO DOOR ENTRY SYSTEM GB2 NEXA MODULAR - BUILDING INSTALLATION DIAGRAMS Video installation with 15 THERA monitors, 4 DP-GB2 distributors and Golmar 12Vd.c lock release: CODE 12 ** CODE 2 ** CODE 0 D BUS End of line OFF BUS BUS THERA A B C BUS BUS THERA BUS THERA Distances and Sections: DP-GB2 THERA C Main 100~240Vac THERA C N N L N.A CN2 B Cable A 2 FA-GB2 Twisted 2x0.75mm 2 Twisted 2x1mm B C Internal rele D 60m 60m 30m 10m 80m 80m 40m 15m A Access door panel D SW1 * ON Configuring the end of line in the last distributor. Switch to On. 1 + ** Configuring the end of line in the last monitor. Dip 6 to On. _ 12Vdc 2 3 4 5 6 C1 NA1 AP- AP+ NA2 C2 AP+ AP- P1 P2 BUSBUS Relé 1 Relé 2 (1) (1) Lock release max. 12 Vdc/270mA. AP (1) Important: For connection of 12Va.c lock release or a 2nd lock release, (see page 26). CN1 FA-GB2 BUS (M) BUS (PL) DP-GB2 D BUS BUS CODE 1 THERA BUS ** BUS CODE 3 THERA BUS ** A B C BUS CODE 13 BUS ** THERA ** DP-GB2 CODE 14 BUS ** End of line ON BUS * THERA 24 VIDEO DOOR ENTRY SYSTEM GB2 NEXA MODULAR - BUILDING INSTALLATION DIAGRAMS Video installation with 15 THERA monitors, 8 D2L-GB2 distributors and Golmar 12Vd.c lock release: * End of line (1) THERA (1) (1) D2 D1 BUS D2L-GB2 THERA C THERA Main 100~240Vac C N N L N.A B CN2 Cable A 2 FA-GB2 Twisted 2x0.75mm 2 Twisted 2x1mm B C Internal rele D 60m 60m 30m 10m 80m 80m 40m 15m A Access door panel D (1) Do not change the factory default position of the configuration jumper. SW1 ON * ** Take off jumper of all the distributors except in the last one. 1 + Configuring the end of line in the last monitor. Dip 6 to On. _ 12Vdc 2 3 4 5 6 C1 NA1 AP- AP+ NA2 C2 AP+ AP- P1 P2 BUSBUS Relé 1 Relé 2 (2) (2) Lock release max. 12 Vdc/270mA. AP (2) Important: For connection of 12Va.c lock release or a 2nd lock release, (see page 26). CN1 FA-GB2 BUS (M) BUS (PL) BUS BUS OFF BUS Distances and Sections: BUS End of line BUS CODE 0 BUS BUS ** BUS D2 D1 BUS THERA CODE 1 D2L-GB2 OFF BUS THERA ** BUS End of line BUS BUS CODE 3 D2L-GB2 D1 BUS THERA ** D2L-GB2 CODE 2 D2 ** BUS CÓDIGO 14 BUS THERA ** ON VIDEO DOOR ENTRY SYSTEM GB2 NEXA MODULAR - BUILDING INSTALLATION DIAGRAMS Video installation with 4 access doors, DP-62 distributor for door panels and Golmar 12Vd.c lock release: To distributors (buiding’s floor) Main 100~240Vac N N L N.A CN2 BUS (M) BUS (PL) End of line OFF Internal rele CN1 FA-GB2 BUS BUS DP-GB2 BUS D BUS C B A Access door panel 4 Access door panel 3 SW1 SW1 ON 1 + _ 12Vdc ON 2 3 4 5 6 1 C1 NA1 AP- AP+ NA2 C2 AP+ AP- P1 P2 BUSBUS Relé 1 Relé 2 + _ 12Vdc (1) 2 3 4 5 6 C1 NA1 AP- AP+ NA2 C2 AP+ AP- P1 P2 BUSBUS Relé 1 Relé 2 (1) (1) (1) AP AP Lock release max. 12 Vdc/270mA. Lock release max. 12 Vdc/270mA. Access door panel 1 Access door panel 2 SW1 SW1 ON 1 + _ 12Vdc ON 2 3 4 5 6 1 C1 NA1 AP- AP+ NA2 C2 AP+ AP- P1 P2 BUSBUS Relé 1 Relé 2 + _ 12Vdc (1) 2 3 4 Relé 1 AP Lock release max. 12 Vdc/270mA. 6 C1 NA1 AP- AP+ NA2 C2 AP+ AP- P1 P2 BUSBUS (1) (1) 5 Relé 2 (1) AP Lock release max. 12 Vdc/270mA. (1) Important: For connection of 12Va.c lock release or a 2nd lock release, (see page 26). 25 VIDEO DOOR ENTRY SYSTEM GB2 NEXA MODULAR - BUILDING INSTALLATION DIAGRAMS Connexion of d.c and a.c Golmar locks release. Connexion of 2 d.c locks release without "AP": Access door panel To FA-GB2 power supply SW1 ON 1 _ + 2 3 4 5 6 C1 NA1 AP- AP+ NA2 C2 AP+ AP- P1 P2 BUSBUS Relé 1 12Vdc Relé 2 (1) (1) Locks release max. 12 Vdc/270mA. (1) Important: Do not use the “AP” push buttons door release if there are connected 2 d.c locks release. Connexion of 1 a.c lock release with "AP": Access door panel To FA-GB2 power supply TF-104 SW1 ON 1 + _ 2 3 4 5 6 C1 NA1 AP- AP+ NA2 C2 AP+ AP- P1 P2 BUSBUS Relé 1 12Vdc Relé 2 SEC PRI ~ ~ ~ ~ Main . 230Vac AP1 Lock release max. 12 Vac/850mA. Connexion of 2 a.c locks release with "AP": Access door panel To FA-GB2 power supply TF-104 SW1 ON 1 + _ 12Vdc 2 3 4 5 6 C1 NA1 AP- AP+ NA2 C2 AP+ AP- P1 P2 BUSBUS Relé 1 Relé 2 AP1 Locks release max. 12 Vac/850mA. SEC PRI ~ ~ ~ ~ AP2 Main . 230Vac 26 VIDEO DOOR ENTRY SYSTEM GB2 NEXA MODULAR - BUILDING NOTES: 27 Sistemas de comunicación S.A. [email protected] www.golmar.es Golmar se reserva el derecho a cualquier modificación sin previo aviso. Golmar se réserve le droit de toute modification sans préavis . Golmar reserves the right to make any modifications without prior notice.