15. Safety and Maintenance 15.4 Maintenance and Troubleshooting 15.4.13 Parameter Setting Tool 15.4.13.1 NC Configurator2 M system : L system : The NC data file necessary for NC control and machine operation (such as parameters, tool data and common variables) can be edited on a personal computer. Please contact us to purchase a full function version. A limited function version is also available free of charge. 15.4.102 Backup M system : L system : This function saves (backs up) the screen data and each controller (PLC, CNC) data to a memory card or a USB memory. It also reloads (restores) that data to each device. If this function is used, the backup is unnecessary for the MONITOR screen and each controller, and work improves. II - 200