Download Laser 30 (Type D) (E)
Transcript
Laser 30 (Type D) (E) 09.1.23 11:10 AM ページ 2 SECTION A: SPECIFICATIONS Model: Laser 30 Heater Efficiency: 90% (1) Heat Rating: High - 15,000 BTU/h Med - 10,000 BTU/h Low - 5,000 BTU/h Fuel Consumption: High - 0.108 gal/h Med - 0.076 gal/h Low - 0.040 gal/h Fuel system: External tank (2) Fuel Type: ASTM D3699 1-K Kerosene, ASTM D396 Low Sulfur No.1 Fuel Oil, or ASTM D975 Ultra Low Sulfur Diesel (ULSD) Dimensions (W × H × D): 16-15/16“ × 21-3/4“ × 13-9/16“ Weight: 31 lbs. Empty Vent Pipe Hole: 2-3/4“ ~ 3“ diameter Maximum Length of Vent Pipe System: 10 ft., 3 bends or less Electrical Rating: 120 Volts AC, 60 Hz Preheat - 260W Burning - 26W Typical Room Size (3): 600 square feet (0°F) 720 square feet (20°F) (1) Heat and vaporized water are produced by the combustion process of this heater. This rating does not take into account heat loss due to condensation of water vapor. (2) External tank to be purchased from local suppliers. (3) 0° F Heat Load = 24 BTU/ft2/hr 20° F Heat Load = 20 BTU/ft2/hr Room size for which this heater is suitable will vary depending on outside temperature, house insulation, window size, and other factors. 2