122 Appendix Error! Main Document Only.Error! Main Document Only.6 - Specifications Interface EIA 232D (Serial RS-232), DCE configuration. 7-8 Data Bits, 1-2 Stop Bits, Full or Half Duplex, Parity: None, Even, Odd, Mark, or Space. Optional software or hardware handshaking: XON/XOFF, DTR/DSR, RTS/CTS. Optional Checksum and Key byte. Jumper or software selectable. Acknowledgements for command set and query. Baud Rates E271-2200 E271-2210 300, 600, 1200, 2400, 4800, 9600, 19200, 38400. 300, 600, 1200, 2400, 4800, 9600, 19200. Jumper or software selectable. Operating Modes Binary or ASCII in SmartSet, E271-140, E261-280, or E281A-4002 protocols. Initial/Stream/Untouch Modes, on-board calibration, coordinate scaling to ±32K, Range Checking, Trim and Tracking Modes. Jumper or software selectable. Touch Resolution Typical raw coordinate output range: 400 .. 3800, 600 .. 3500. No missing coordinates. Conversion Time E271-2200 Typically 20 ms as shipped (9600 baud, no scaling). 6 ms possible (38K baud, software selectable delay between packets removed). E271-2210 Typically 21 ms as shipped (9600 baud, no scaling). 7 ms possible (19.2K baud, software selectable delay between packets removed). Reliability E271-2200 E271-2210 MTBF of 74,738 hours per MIL-HDBK-217E, Notice 1 update. MTBF of 107,527 hours per MIL-HDBK-217E, Notice 1 update.