NASA USRP - Internship Final Report
Typical output from spectrometer:
Known issues:
Reducing the accumulation length has a substantial chance to cause the accumulator to lock up
for the next 3hr, 15min. Doing so is not recommended. Workaround: re-program the fpga when
starting a shorter accumulation. This issue can be resolved in a future release, if there is
sufficient demand.
It is worth noting the presence of harmonics in the spectrum of our output: this appears to be
caused by the ADCs used in our setup (National Semiconductor 083000s). The first harmonic is
generally 25dB to
35dB below the level of the desired output.
In addition, channel 2048 on both pols is corrupted due to (in my opinion) the gain/offset
mismatch between the two internal ADCs on each 083000. Those channels must be ignored.