Download FOR SOFTWARE VERSION 1.45 * * RELEASE DATE: FEB. 24th, 2004
Transcript
TECHNICAL MANUAL PARAMETER 63 - CURRENT LOOP (GROSS OR NET MODE) Description: Sets the current loop to operate in GROSS mode or NET mode. GROSS: For most applications. 4 mA is output when the scale is at zero (Centre of Zero LED illuminated). NET: For applications with varying tare weights. The 4-20 mA board will output only after a tare has been entered. 4 mA is out put when the weight display shows zero, even though the true weight on the scale is greater (NET LED illuminated). PARAMETER VALUE CURRENT LOOP MODE 0 (default) 1 GROSS mode NET mode PARAMETER 64 - CURRENT LOOP (SPAN) Description: Spans the Current Loop Output to a custom weight entry. This is the weight at which the Current Loop will output its highest level (20 mA). The True Scale Capacity weight is typically selected. In some applications (such as those utilizing NET mode), a weight less than Scale Capacity is desired. Enter the weight on the keypad, followed by the [PRINT/SELECT] key. If, for example, the scale capacity is 1000 kg, but Parameter 64 is set to 500 kg, the Current Loop will reach 20mA at 500 kg. IF, FOR ANY REASON, THE M2000 STOPS TRANSMITTING COMMANDS TO THE 4-20 MA BOARD, THE CURRENT LOOP OUTPUT WILL BE SET TO ZERO. 83