HIGH SPEED DIGITAL WEIGHT INDICATORS
M2000 SPECIFICATIONS
INDICATOR PERFORMANCE
UNIT CONVERSION
ZERO TRACKING
RESOLUTION (M2000A)
RESOLUTION (M2000D)
SAMPLING RATE
SPAN STABILITY
ZERO STABILITY
LINEARITY CORRECTION
CALIBRATION METHOD
CALIBRATION SEALING
FILTERING
MODES
FIRMWARE UPGRADING
LOAD CELLS
LOADCELL INPUTS
FULL SCALE
EXCITATION (M2000D)
EXCITATION (M2000A)
COMMUNICATIONS
SERIAL OUTPUTS
IO INTERFACE
EXTERNAL IO:
SETPOINTS
EXTERNAL IO:
ANALOG OUTPUT
EXTERNAL IO:
DIGITAL INPUTS
NETWORKING
lbs / kg
1-99% of d or 1,2,3d
+/- 520,000 A/D counts per loadcell
+/- 256,000 A/D counts per loadcell
100 times per second per AD channel
2ppm/ Celsius
5nV/Celsius
5 span entries
Calibration through software stored in Flash memory
Class 1 Audit Trail System, password protected
FASTSTEP quick response
Display from CH1, CH2, CH3 and TOTAL MODE (All Channels)
Flash Memory - In field Firmware upgrading without affecting
calibration data.
Up to 16 Loadcells using two DLC slaves
4 ranges: 0-9mV, 0-19mV, 0-39mV, and 0-79mV
5VDC,16x350, 32x700 ohm in total
7.5VDC,16x350, 32x700 ohm in total
2 full duplex RS232/RS422 (1 only with Single Channel model)
SMART WIRE peripheral expansion: RS485 multi-drop
6 channel Setpoint via SMARTWIRE (optional)
4-20mA board via SMARTWIRE (optional)
6 optically isolated inputs via SMARTWIRE (optional)
RS485 Multi-drop Networking of up to 32 indicators as slaves
ELECTRICAL
POWER REQUIREMENTS
POWER DRAW
TEMPERATURE RANGE
RFI PROTECTION
12VDC, 1 Amp. (1.5A maximum)
200 mA
-10C to +40C
Filtered Signal, Excitation, & Sense lines
ENCLOSURES
STAINLESS
Wash-down stainless steel enclosures. Panel mount, swivel-bracket, or
desktop. Light Stainless or NEMA 4-X.
ALUMINIUM
Slimline. M2000A only. 12 GA. Cast aluminium.
APPROVALS
MEASUREMENT CANADA
NTEP
CSA
OIML
20
CSA Approved Power Supply