R&S®UPP Instrument Function Distortion Measurements Even Harmonics Used to select the desired even harmonics; only available if "(Level) Select di" is selected under "Meas Mode". SCPI command: SENSe:FUNCtion:DISTortion<n3> on page 693 <n3> designates harmonics 2 ... 9 Odd Harmonics Used to select the desired odd harmonics; only available if "(Level) Select di" is selected under "Meas Mode". SCPI command: SENSe:FUNCtion:DISTortion<n3> on page 693 <n3> designates harmonics 2 ... 9 Fundamental Used to determine the fundamental frequency. "Auto" The fundamental frequency is determined (separately for each channel) by means of internal frequency measurement. Recommended for use with an external signal source. "Value" Fixed fundamental frequency; the value must be entered in the parameter field below. Recommended for signals with a high noise component if an external generator is used as the signal source. User Manual 1411.1055.32 ─ 03 358