Model 2806 Limited Distance Solution (LDS) 77 Ch. Tx
2.7
A)
Unit Outline Drawing
Optical Out (SC/APC Standard, FC/APC
Optional): Optical output to the receiver.
C)
WARNING
OPTICAL LASER RADIATION IS PRESENT AT
THE TRANSMITTER’S CONNECTOR WHEN
THE UNIT IS TURNED ON. AVOID DIRECT EYE
EXPOSURE TO THE INVISIBLE BEAM.
B)
Installation Instructions
RF Input (F Connector): RF signal input into the
transmitter. Warning label above advises not to
exceed the RF input level, or the transmitter may
be destroyed.
D)
E)
F)
RF Level LED (Tri-colored LED): When green,
indicates the unit RF output is at the optimum
level. If the RF signal falls below optimum, the
LED will turn yellow. If the RF signals rise above
the optimum, the LED will turn red.
RF Test (F Connector): Allows the user to
measure the output RF levels 20 dB down from
the primary output.
Power (3-wire ground AC power cable):
Connects the unit to any AC wall output.
Status (3-Pin Pheonix Connector): Outputs
information about the status of the unit.
Figure 2.1 CATVLinx® Model 2806 LDS transmitter
(Dimensions in parentheses are in millimeters.)
2.8
Safety Precautions
The optical emission from the units are laser-based Class IIIb, and may present eye
hazards if improperly used. NEVER USE ANY KIND OF OPTICAL INSTRUMENT TO VIEW THE OPTICAL OUTPUT OF THE UNIT. As always, be careful when working with optical fibers. Fibers can cause painful injury if they
penetrate the skin.
CAUTION
Caution — Use of controls or adjustments or performance procedures other than those
specified herein may result in hazardous radiation exposure.