Download PhoneWatchSmart Security System User Manual

Transcript
Description of the alarm
system
How to use the keypad
and keytag
The control unit is the brain of your alarm system. It exchanges information with the
wireless components that are connected. The control unit collects data that is sent by
the sensors, it registers arming and disarming and communicates with the PhoneWatch
Alarm Receiving Centre.
The keypad is equipped with a keytag reader allowing users to arm/disarm the alarm
system using either a valid code or keytag.
It also has an internal siren. The keypad can have up to 9 users configured. To add,
remove or configure users, please contact PhoneWatch.
PROPERTIES
RADIO
ALARM TRANSMISSION
•Narrow band FM, 868 MHZ
• Built-in alarm transmitter
•Unique identification for every component in the
system, interference from neighbouring systems is not
possible
• Transmission is monitored using periodical testing
• Reports interference
KEYTAG READER
SIREN
ARM/DISARM AREA
FUNCTIONS
• 3 settings: Away and Home and Off
ELECTRICS
•220v - 240v ac with battery back-up
•Built-in surge protection
•Monitoring of power supply
• Up to 24 sensors
• Alert functions
• Control unit and sensors are tamper-proof
LOUD
SPEAKER
PANIC BUTTONS
SYSTEM FAULT
(Light2)
SYSTEM ARMED
(Light1)
ALARM ACTIVATED
(Light3)
Tamper
ALERT (Light4)
ARMING BUTTON FOR
WHOLE SYSTEM (AWAY)
ARMING BUTTON FOR
PART OF SYSTEM (HOME)
4
KEYTAG
5