Tubing Pressure Overrides – Tubing Pressure Overrides configuration.
Table 21. TP Overrides
Item
Open if TP is
greater than
Close if TP is
less than
Fast arrival,
high TP
decrease
Slow arrival,
high TP
increase
No arrival, high
TP increase
Fast arrival, low
TP decrease
Slow arrival,
low TP increase
No arrival, low
TP increase
Min TP shut in
Max TP shut in
Only honor TP
overrides in
afterflow
9/15/2008
Description
Opens the tubing valve if the Tubing Pressure is greater
than or equal to the PSIG setting. Will only override time if
Minimum Off Time has expired.
Closes the tubing valve if the Tubing Pressure is less than
or equal to the PSIG setting.
Amount the “Open if TP is greater than” value will be
decreased by for each fast cycle.
Amount the “Open if TP is greater than” value will be
increased by for each slow cycle.
Amount the “Open if TP is greater than” value will be
increased by for each no arrival.
Amount the “Close if TP is less than” value will be
decreased by for each fast cycle.
Amount to increase the “Close if TP is less than” value will
be increased by for each slow cycle.
Amount to increase the “Close if TP is less than” value will
be increased by for each no arrival.
Minimum tubing pressure at which the controller will be
put into manual mode and the tubing valve will be closed.
Maximum tubing pressure at which the controller will be
put into manual mode and the tubing valve will be closed.
When True, the ACiC will only honor tubing pressure
overrides for closing valves during the afterflow cycle.