3.6.6
Switching off with Tape Threaded
It is good practice to ensure that the tape is unloaded (or at least returned to BOT) before switching off. The
reel servo circuits are designed with a dynamic braking effect to prevent tape loops forming following power
failures or accidental switching off.
3.7 9914 Problems
The 9914 has extensive internal diagnostic facilities to simplify fault isolation.
If a fault is found, a message appears on the operator's display, Table 3.3 lists these indications. Read this
section to determine whether the 9914 is suitable for further operation; if not, rewind the tape and unload the
reel.
In general, it is only necessary to switch off when some obvious hazard is present; removing power from one
9914 in a daisy-chain configuration may disable the whole configuration.
If the 9914 does not operate as expected, and no fault indication is displayed, consult Tables 3.7.X.
3.7.1
Reading Seismic Tapes
It sometimes happens that a tape, which is known to contain seismic information, repeatedly fails to read
and causes the IN LIMIT or CHECK MEDIA CONDITION message to appear on the operator’s display.
Such a tape:
a. is likely to have data blocks far exceeding the normal maximum length of 64K bytes, and / or
b. may have been stored in adverse conditions, and / or
c. may have been stored for a very long time,
and the normal read re-try action (involving a tape reposition) will not recover the data successfully because
the tape “sticks” to the head stack (a phenomenon known as stiction).
Firmware Conditions Necessary to Read Seismic Tapes
Facilities have been provided to enable seismic tapes to be read with greater success, it is recommended
that a Service Engineer installs these facilities but there follows a description of the procedure.
- Run diagnostic program 70 to establish which SCSI board is fitted. PROM 124610 denotes that Super SCSI
is fitted; any other SCSI PROM does not support the seismic option. If the PROM is 124610, note its
revision.
If PROM 124610 revision is 07 or later, the seismic option can be supported.
- Run diagnostic program 70 again to establish which Servo Control code is fitted. The code must be A4/28
or later in order to support the retention of servo parameters in the event of the tape tension having been lost.
Setting Up Seismic Read Parameters
If the previous 2 conditions are satisfied, seismic operation can be supported by setting another 2
conditions, as follows. Caution: do not set up seismic operation in order to read non-seismic tapes.
- Config Byte 14, bit 6 must be set to ‘1’, this enables seismic operation. Alternatively, if Super SCSI options
are controlled by on-board switches, SW2/2 must be set ‘on’. Seismic operation causes a Read command
to keep the tape streaming until the preset number of file marks is detected, without stopping on error or
reporting errors.
3 - 18
9914 User/Diagnostic Manual
CM 1077 (Issue 2 + Amdt 3)