Download 28 MT starter

Transcript
PAGE
20
1M-128
28-MT STARTER
4/96
28-MT STARTER SPECIFICATIONS
All 28-MT, 12 Volt models have these
No Load Test Specifications
Amps
Volts
Minimum
10
125
RPM
Maximum
Minimum
190
3000
Maximum
5600
All 28-MT, 24 volt models have these
No Load Test Specification
Volts
20
Amps
RPM
Minimum
Maximum
Minimum
Maximum
75
90
3600
5400
28-MT, Starter Solenoid current consumption
Pull in Winding
Hold in Winding
Rated
Voltage
Amps
Volts
Ohms
Amps
Volts
Ohms
12
52 - 59
10
0.17 - 0.19
12 - 14
10
0.76 - 0.81
24
100 - 125
20
0.16 - 0.20
12 - 14
20
1.15 - 1.65
For further information on rotations and exact specifications
on these or other Delco Remy America Products:
Call 1-800-DRA-0222