AMPS START AMPS WATTS 4,7 19 950 5,2 29 1180 A/EC 206 A A/EC 206 W A/EC 226 A A/EC 226 W KWH/24HRS REFR. CHARGE R404a 20,8 17,3 24,2 19,2 320 gr 250 gr 450 gr 300 gr SUCT. PRESS. END. FREEZE DISCHARGE PRESSURE 15 ÷ 17 bar 17 bar 15 ÷ 17 bar 17 bar 1,7 bar 1,7 bar DIP SWITCH FACTORY SETTING COMBINATIONS (PER MODEL AND VERSION) COMBINAISON DES COMMUTATEURS NUMERIQUES DU DIP SWITCH POUR MODELES ET VERSIONS REGOLAZIONE TASTI DIP SWITCH PER MODELLO E VERSIONE FREEZING CYCLE CYCLE DE CONGÉLATION CICLO CONGELAMENTO DIP SWITCH A/ECS 226 A A/ECM 206-226 A A/ECM 206-226 W A/ECL 206 A A/ECL 206 W 2 ON ON OFF OFF ON ON OFF OFF ON ON OFF OFF ON 7 8 2 3 4 5 6 7 8 9 10 OFF ON ON OFF OFF ON OFF OFF OFF OFF ON ON ON ON ON OFF OFF OFF OFF OFF ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON OFF ON OFF 3 ON ON ON ON OFF OFF OFF OFF ON ON ON ON OFF 4 ON ON ON ON ON ON ON ON OFF OFF OFF OFF OFF ON 0 ON 30 sec. ON OFF 60 sec. OFF OFF 1 min. 3 min. 5 min. 7 min. 9 min. 11 min. 13 min. 15 min. 17 min. 19 min. 21 min. 23 min. 25 min. ADDITIONAL DEFROST TIME TEMPS AJOUTÉS TEMPI AGG. SCONGELAMENTO ON 8 AIR/EAU ARIA/ACQUA 1 OFF 7 15/30" ON ON ON OFF OFF TIMED PORTION FREEZING CYCLE TEMPS PHASE TEMPORISÉE CONGELATION TEMPI FASE TEMPORIZZATA CONGELAMENTO 1 ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON DEFROST CYCLE CYCLE DE DÉMOULAGE CICLO SBRINAMENTO WATER PUMP OFF DURING DEFROST POMPE A L’ARRÊT PEND. DEGIVRAGE POMPA ACQUA DURANTE SBRINAMENTO LED STATUS ON STEADY FIXE FISSO REASON WHY - SIGNIFICATION - SIGNIFICATO FREEZING CYCLE EN RÉFRIGÉRATION IN CONGELAMENTO BLINKING 60 MINUTES DELAY AT START UP JUMPER J3 OUT CLIGNOTANT 60 MINUTES DE RETARD AU DEMARRAGE - CAVALIER J3 OUVERTE LAMPEGGIANTE 60 MINUTI RITARDO PARTENZA - CONTATTI J3 APERTI ON STEADY FIXE FISSO TOO HI DISCHARGE PRESSURE/TEMP. COUPURE HP FERMATA ALTA TEMP. CONDENSAZIONE BLINKING TOO HI EVAP. TEMP. (> 0°C) AFTER 15’ FROM START UP CLIGNOTANT COUPURE BP ( > 0°C LU PAR LA SONDE EVAP. NON ATTEINTE APRES 15’ FONCT.) LAMPEGGIANTE TEMP. EVAP. > 0°C DOPO 15’ DA INIZIO CONGELAMENTO ON STEADY FIXE FISSO UNIT OFF AT BIN FULL CABINE PLEINE CONTENITORE PIENO BLINKING SLOW I/R BEAM CUTTED CLIGNOTANT LENT FAISCEAU INFRA ROUGE CELLULE NIVEAU GLACE INTERROMPU LAMPEGG. LENTO RAGGIO INFRAROSSO INTERROTTO BLINKING FAST I/R ON AFTER TRIP OFF AT BIN FULL CLIGNOTANT RAPIDE FAISCEAU INFRA ROUGE CELLULE NIVEAU GLACE ETABLI LAMPEGG. VELOCE RAGGIO INFRAROSSO RIPRISTINATO DOPO FERMATA A CONT. PIENO ON STEADY FIXE FISSO I/R CALIBRATION DONE CALIBRATION FAISCEAU INFRA ROUGE CELL. NIVEAU GLACE REALISÉ CALIBRAZIONE RAGGIO INFRAROSSO EFFETTUATA BLINKING UNIT IN CLEANING MODE OR TRIPPING OFF AFTER TEST - JUMPER TEST IN CLIGNOTANT MACHINE EN MODE DETARTRAGE OU ARRÊTE APRES LE TEST - CAVALIER TEST FERMÉ LAMPEGGIANTE MACCHINA NELLA FASE LAVAGGIO O FERMA DOPO IL TEST - PONTICELLO TEST CHIUSO ON STEADY FIXE FISSO CONDENSER SENSOR OUT OF ORDER SONDE CONDENSEUR HS SONDA CONDENSATORE MALFUNZIONANTE BLINKING EVAPORATOR SENSOR OUT OF ORDER CLIGNOTANT SONDE EVAPORATEURS HS LAMPEGGIANTE SONDA EVAPORATORE MALFUNZIONANTE BLINKING ALTERNATIV. I/R SENSOR OUT OF ORDER CLIGNOTANT ALTERNÉ SONDE INFRA ROUGE CELLULE NIVEAU GLACE HS LAMPEGGIO ALTERN. SONDA ALL’INFRAROSSO LIVELLO GHIACCIO MALFUNZIONANTE PUSH PUSH > 5” DURING WATER FILLING TO MOVE THE UNIT INTO FREEZING PUSH > 5” DURING FREEZING TO MOVE THE UNIT INTO DEFROST PUSH > 5” DURING DEFROST TO MOVE THE UNIT INTO FREEZING PUSH 2” ÷ 5” DURING WATER FILLING TO MOVE THE UNIT INTO CLEANING PUSH DURING THE 60 MIN START UP DELAY TIME TO BY-PASS IT