LOCKWELT 3000 TROUBLESHOOTING DIAGNOSTICS Service Tests Clamp Motor F3 Clamp Motor Long Term Test Note: The main clamp must be in the starting position, clamp on initiator 17. Press the F3 key. Press the ENT key, the main clamp must move back and forth in high speed and change direction at the same position. Tab Knife Motor Press the yellow P key. Press the F6 function key. Press the F3 function key. Press the F4 function key. The submenu includes 2 tab knife motor tests, press the corresponding F key to access each test. F1 Select Tab Knife Motor Caution! This test is to be performed by qualified personnel only. F2 Tab Knife Motor Long Term Test The tab knife must be in the correct starting position, on indicator 20. Press the F2 key. Press the ENT key, the tab knife moves back and forth with consistent speed and changes direction at the same location. Using the mains rotary switch, switch off the main machine power to end the test. Center Knife Motor Press the yellow P key. Press the F6 function key. Press the F3 function key. Press the F5 function key. Enter a value between 01 and 99 to check the speed of the center knife motor. Press the ENT key to switch off the motor. To switch the center knife motor on, Press the 0 (zero) key. To stop the center knife, Press the ENT key. Press the P key to end the test. Released January 2001 U.S. Phone 800-237-3323 Outside U.S. Phone 1-804-559-5000 Fax 1-804-559-5210 2-17