Download LOCKWELT 3000
Transcript
LOCKWELT 3000 TROUBLESHOOTING SYMPTOM POSSIBLE CAUSE Turning the main electrical power rotary switch off, turning the main electrical power on and releasing the Program Stop push-button will Reset the machine and sometimes clear an Error message. It is recommended before troubleshooting procedures are performed. Error message displayed Error - 01 = Sewing program empty Distances and values are not entered, or the program was deleted. Error - 02 = Pocket style deactivated Pocket style number is not highlighted. Error - 05 = I/O communication Transfer error between controls and the I/O module. error Faulty controls. Faulty I/O module. Error - 06 = Invalid path pulses If the clamp motor performs a small movement, the path pulses won´t process correctly. Motor fault. Faulty activation or power part of the clamp motor. 2-4 Manually enter the program values or copy from other programs or load from memory. Initial parameters. Press the ENT key to activate and highlight the pocket style. Check the wire connections. Replace the controls. Replace the I/O module. Incorrect clamp sledge position. Faulty adaptation module 9020020 Error - 07 = No path pulses from the clamp motor POSSIBLE SOLUTION Check the generator connection to the clamp motor. Check the adaptation module flat conductor plug 9020020 and 9020013. Replace the adaptation module 9020020. Check the clamp motor connection. Replace the clamp motor. Replace the adaptation module 9020020. Check the power card diodes. Perform motor diagnostic check of connection 9020020. Replace the adaptation module 9020020. Released January 2001 U.S. Phone 800-237-3323 Outside U.S. Phone 1-804-559-5000 Fax 1-804-559-5210