SynchroNet ES/2 User Guide
ES/2 Operations Reference
PROTO
Replaces the ESbus Address menu when Emulation mode is selected. A number of protocol
options are available:
BVW
Simulates a Sony BVW75 video machine.
BVH
Simulates a Sony BVH3000 video machine.
SSL
Same as a BVW75 except that some technical alterations to the machine responses are
made to suit the SSL Screensound.
Ampex
This is not implemented in Comms Software revision 3.04.
Zeta96
Simulates a Adams Smith Zeta3 running at 9600 baud (the default for RS232 connections
on a Zeta3).
Zeta38
Simulates a Adams Smith Zeta3 running at 38.4k baud (the default for RS422 connections
on the Zeta3).
2600
Simulates a Adams Smith 2600 (running at 9600 baud).
Bus B
Determines the mode of the ES/2 on bus B when in EMUL mode on bus A.
Ch-M
When the Emulator has been selected on bus A, it is possible to enable a chase master on
bus B. Other modules selected as chase slaves will then follow this master.
EXT
Enables a Penta remote master system to co-exist on bus B. When this option is selected,
the protocol selection list is replaced by the ESbus menu.
See Serial*Share.
off
No activity is generated on bus B.