Download High Precision Tank Gauging System
Transcript
Technical Description 703010En, Ed. 3, Rev G June 2007 TankRadar Rex Ex Reference Pin Still-pipe ø 100 mm The reference pin mounted inside the 4-inch still-pipe and a bottom reflection ring enable the measurement to be checked during operation. Technical Data for RTG 3960 See also technical data for the Transmitter Head. Instrument accuracy: RTG 3960 ± 0.5 mm ± (5/256 in.) RTG 3960 L ± 3 mm ± (1/8 in.) Operating temperature at ball valve: -55 °C to 90 °C (-67 °F to 194 °F) Operating temperature in tank: -170 °C to 90 °C (-274 °F to 194 °F) Measuring range: 0.5 m to 60 m (1.6 ft to 200 ft) from cone end. For longer measuring range, please consult your Rosemount Tank Gauging representative. Maximum pressure: Up to 25 bar (365 psig). (Note! Flanges may have higher pressure rating than 25 bar, but maximum tank pressure is still 25 bar). Pressure rating: 10 bar/150 psi 20 bar/300 psi 40 bar/600 psi Pressure sensor (option): Druck PTX 621 Flange: 6-in. Still-pipe dimension alternatives: 4-in. sch. 10 or sch 40 100 mm (99 mm inner diameter). Total weight: 38 kg (84 lbs) for 6-in. 150 psi 48 kg (106 lbs) for 6-in. 300 psi Material exposed to tank atmosphere: Antenna: Acid proof steel type EN 1.4436 (AISI 316) Sealing: Quartz Ball valve sealing kit (option): 20 bar or 60 bar (290 psi or 870 psi), the higher pressure for 600 psi flange only Field data display: In separate DAU (page 26) or RDU (page 27) 21