R&S®SMF100A Error Messages Status Information However, the frequency entered and displayed in the "Frequency/Phase" dialog of the "RF" function block always corresponds to the RF output frequency. Any frequency offset is not taken into consideration. The correlation is as follows: Freq in header = RF output frequency (= Freq in dialog) + Freq offset (= Offset in dialog) LEVEL OFFSET A level offset is set. The level entered and displayed in the "Level" field takes the offset of any downstream attenuators/amplifiers into consideration by way of calculation. This means that with a level offset the level displayed in the header does not correspond to the level at the RF output, but rather to the level at the output of the downstream instrument. This allows the target level at the output of downstream instruments to be entered. The signal generator changes the RF output level according to the set offset. However, the level entered and displayed in the "Level" dialog of the "RF" function block always corresponds to the RF output level. Any level offset is not taken into consideration. The correlation is as follows: Level in header = RF output level (= Level in dialog) + Level offset EXT REF An external reference is used. The external signal with selectable frequency and defined level must be input at the REF IN connector. It is output at the REF OUT connector. BUSY A setting or calculation is executed. 9.1.2 Status information displayed to the left of the Info line This chapter gives an overview of the status messages displayed to the left of the Info line. REMOTE The instrument is remote controlled. The keys on the front panel are usable, but all parameters are in read only mode. The LOCAL key switches the instrument from remote control to manual operation. The current command must be fully processed before the mode is switched, otherwise the instrument switches immediately back to remote control. REM-LLO The instrument is remote (REMote) controlled. The LOCAL key is disabled by remote control with the command LLO (LocalLockOut). The keys on the front panel are usable, but all parameters are in read only mode. Operating Manual 1167.2319.32 ─ 08 556
Related documents
Connectivity of Rohde & Schwarz Signal Generators Application Note
Template R&S Datenblätter/Produktbroschüren/Specs
R&S®SMA100A Operating Manual
Rohde & Schwarz SMA100A Signal Generator
Anritsu MG3642A User's Manual
R&S SMF100A Générateur de signeaux micro
R&S SMC100A Operating Manual
R&S SMBV100A Vector Signal Generator Operating Manual
R&S SMB100A Complete Manual
Manual - Test Equipment Depot
Motorola StarMax User`s guide
R&S SGS100A User Manual