R&S FSG Instrument Functions Analyzer Mode The setting of the sweep count in the TRACE menu is equivalent to the setting in the SWEEP menu. Remote command: SWE:COUN 64 DETECTOR See following section “Selection of Detector” on page 4.44. TRACE MATH See following section “Mathematical Functions for Traces” on page 4.48. MIN HOLD The MIN HOLD softkey activates the min peak detector. R&S FSG saves for each sweep the smallest of the previously stored/currently measured values in the trace memory. The detector is automatically set to MIN PEAK. In this way, the minimum value of a signal can be determined over several sweeps. This function is useful e.g. for making an unmodulated carrier in a composite signal visible. Noise, interference signals or modulated signals are suppressed by the min hold function whereas a CW signal is recognized by its constant level. Pressing the MIN HOLD softkey again clears the trace memory and restarts the min hold function. Remote command: HOLD CONT (ON OFF) DISP:WIND:TRAC:MODE MINH The HOLD CONT ON/OFFsoftkey defines whether the traces in min hold and max hold mode are reset after some specific parameter changes. • OFF: The traces are reset after some definite parameter changes (default) • ON: This mechanism is switched off. In general, parameter changes require a restart of the measurement before results are evaluated (e.g. with markers). For those changes that are known to require a new measurement (e.g. modification of the span), the trace is automatically reset so that erroneous evaluations of previous results are avoided. This mechanism can be switched off for those exceptional cases where the described behavior is unwelcome. Remote command: AVG MODE :DISP:WIND:TRAC:MODE:HCON ON|OFF The AVG MODE softkey selects logarithmic or linear averaging for the logarithmic level display mode. At the same time the difference calculation is switched between linear and logarithmic in submenu TRACE MATH. Remote command: CALC:MATH:MODE LIN|LOG|POW With logarithmic averaging, the dB values of the display voltage are averaged or substracted from each other with trace mathematical functions. With linear averaging the level values in dB are converted into linear voltages or powers prior to averaging. Voltage or power values are averaged or offset against each other and reconverted into level values. For stationary signals the two methods yield the same result. Operating Manual 1309.0090.12 - 05 4.41
Related documents
R&S®FSQ User Manual - Rohde & Schwarz Colombia
FSQ Operating Manual English FW 4.55
R&S®ESPI Operating Manual
Note - MATsolutions
R&S®FSU Operating Manual
R&S®FSP Operating Manual
HP 8970B Option 020 Service Manual Supplement
R&S
R&S FSQ-K10x EUTRA/LTE UL Measurement
R&S FSE Series Operation Vol 2
R&S ESR EMI Test Receiver - Rohde & Schwarz Middle East and
Operating Manual FSP Vol. 2